Description
Designed for high-density IT environments, the Tripp Lite by Eaton 3.7kW Single-Phase Local Metered PDU delivers dependable power distribution with real-time visibility. This compact, 0U vertical unit is purpose-built for data centers, server rooms, and network closets where space is at a premium and reliability is non-negotiable. With a robust set of outlets (32 C13s and 6 C19s) and a local metering display, it puts critical load information at your fingertips, enabling operators to optimize performance, prevent overloads, and reduce energy costs. Built by the trusted Tripp Lite brand under the Eaton umbrella, this PDU combines rugged construction with precise power monitoring to support continuous operation in demanding environments. Whether you’re expanding a rack, refreshing aging infrastructure, or standardizing on metered power distribution, this PDU is engineered to simplify management without sacrificing efficiency or safety.
- Real-time local metering with amp-level visibility: The unit provides immediate feedback on current draw, helping technicians gauge load distribution across outlets and prevent overloading critical devices. This on-device monitoring supports proactive capacity planning and steady uptime in busy data centers.
- Versatile outlet configuration for modern IT gear: With 32 C13 outlets and 6 C19 outlets, this PDU accommodates a wide range of servers, storage, and networking equipment. The mix of outlets supports common power adapters while keeping cabling organized and accessible for maintenance windows.
- 208/230V compatibility for modern IT environments: Designed to support the voltage standards used by today’s servers and network devices, this PDU ensures compatibility with mainstream data center power architectures, simplifying integration into existing racks and power distribution architectures.
- Space-saving 0U vertical form factor: The slim, rack-mountable design maximizes rack efficiency by occupying no front-panel space in the 0U slot, leaving more room for equipment and cable management. Ideal for dense racks and installations where every inch counts.
- Trusted performance from Tripp Lite by Eaton: Built for continuous operation in demanding environments, this PDU reflects the durability, safety features, and serviceability that IT teams rely on to maintain uptime, reduce maintenance cycles, and simplify asset management.
Technical Details of Tripp Lite by Eaton 3.7kW Single-Phase Local Metered PDU
- Model: Tripp Lite by Eaton 3.7kW Single-Phase Local Metered PDU
- Power capacity: 3.7 kW
- Phase: Single-phase
- Voltage: 208/230V
- Outlet configuration: 32 x C13, 6 x C19
- Input/output: 208/230V compatibility with standard IT power distribution
- Form factor: 0U vertical rack-mountable
- Special features: Local metering with real-time load readouts
- Connectors: IEC309 blue 16A power connectors (perimeter protective rating and color-coding)
How to install Tripp Lite by Eaton 3.7kW Single-Phase Local Metered PDU
- Plan the rack placement: Identify a suitable 19-inch rack location with access to an appropriate 208/230V power source and sufficient clearance for front access and cabling. Confirm that a 0U vertical installation aligns with your rack’s mounting rails.
- Mount the PDU: Secure the 0U vertical PDU into the rack using the provided mounting brackets or accessories. Ensure it is level and firmly fastened to minimize vibration and movement during maintenance or airflow management.
- Connect power input: Attach the main power input to a suitable 208/230V feed that matches the PDU’s rating. Use proper cables and connectors, and verify that the supply circuit is protected by an appropriate overcurrent protection device as per local electrical codes.
- Route outlets and devices: Plan outlet distribution to minimize cable clutter and optimize airflow. Connect servers, storage, and network equipment to the C13 and C19 outlets, grouping devices by power profile to balance the load across the PDU.
- Power-on and calibrate: Power up the rack and verify that the PDU’s local metering readout displays current draw accurately. Check for error indicators, confirm outlet functionality, and ensure the load remains within safe operating thresholds.
- Document and monitor: Label circuits and outlets for easy identification during maintenance. If your facility requires it, integrate with facility management processes to track energy usage, capacity, and peak demand over time.
Frequently asked questions
- What is a Local Metered PDU? A Local Metered PDU provides on-device monitoring of power usage, including real-time current draw, and often kilowatt-hour measurements. It helps data center teams observe load distribution directly at the rack without requiring remote monitoring hardware.
- What outlets are included in this PDU? This model offers 32 C13 outlets and 6 C19 outlets, enabling a flexible mix of common IT devices from servers to network appliances while keeping power organized in a dense rack environment.
- What voltage does it support? The PDU is designed for 208/230V operation, aligning with standard data center and IT equipment power requirements and simplifying integration into existing power architectures.
- Is remote monitoring supported? This specific Local Metered PDU emphasizes on-device metering. For remote monitoring capabilities, consider a network-enabled or intelligent PDU option that provides SNMP, web, or software-based management features.
- How can I ensure safe installation? Follow standard electrical and rack-mount best practices: verify compatibility with your rack, ensure proper circuit protection and grounding, avoid overloading outlets, and perform power-on checks with careful attention to cabling and airflow.