Description
Tripp Lite by Eaton 3U Digital Temperature Sensor with 2 12VDC Extra-Quiet Fans, Blanking Panel, LCD
Meet the Tripp Lite by Eaton 3U Digital Temperature Sensor system—a comprehensive, rack-mount cooling and monitoring solution designed to protect critical server equipment while optimizing airflow in dense data centers, edge closets, and data room environments. Built to integrate seamlessly with standard 19-inch racks, this 3U device combines intelligent temperature sensing, noise-conscious fans, and a ready-to-use blanking panel to eliminate airflow leaks. Whether you’re deploying a new rack enclosure or upgrading an existing setup, this unit provides precise temperature data, responsive cooling, and a tidy, professional install that helps you manage heat, reduce energy costs, and extend the life of your equipment.
- Robust 3U, rack-mount cooling with focused airflow: This unit leverages two 12V DC extra-quiet fans and a digital temperature sensor to actively monitor rack temperatures and deliver targeted cooling where your gear runs hottest, helping prevent thermal throttling and equipment failure in high-density deployments.
- Real-time temperature monitoring with an easy-to-read LCD: A built-in LCD display presents current temperature readings at a glance, enabling quick diagnostics and proactive cooling decisions. The digital sensor ensures accurate, up-to-the-second data you can rely on for precise fan control and environmental management.
- Airflow optimization with a blanking panel: Included blanking panel seals off empty rack spaces to prevent hot air recirculation and backflow, maximizing cooling efficiency, reducing energy waste, and maintaining a stable thermal envelope for your servers and network appliances.
- Silent, efficient operation for data centers and offices: The extra-quiet design minimizes noise disruption in data rooms, server closets, and office environments where a quiet workspace is important, while still delivering the cooling power needed for modern equipment.
- Easy installation in standard 19-inch racks with enterprise reliability: Engineered for straightforward, tool-free mounting in typical data center racks, this Tripp Lite by Eaton solution offers durable construction and reliable performance trusted by IT professionals for years.
Technical Details of Tripp Lite by Eaton 3U Digital Temperature Sensor with 2 12VDC Extra-Quiet Fans, Blanking Panel, LCD
- Height/Size: 3U rack-mount enclosure designed for standard 19-inch racks
- Cooling components: 2 x 12V DC extra-quiet fans
- Monitoring: Digital temperature sensor with LCD display for real-time readings
- Airflow management: Includes blanking panel to minimize hot air leakage and optimize cooling efficiency
- Display: Built-in LCD for easy temperature visibility and quick status checks
How to install Tripp Lite by Eaton 3U Digital Temperature Sensor with 2 12VDC Extra-Quiet Fans, Blanking Panel, LCD
Installing this 3U cooling and monitoring unit is designed to be straightforward in a standard 19-inch rack. Follow these steps to ensure a secure fit and optimal performance:
1) Plan placement: Identify the rack bay where the device will be mounted and confirm there is adequate clearance for the fans and LCD display. Consider proximity to power distribution units, network equipment, and any existing cable management to minimize airflow obstructions.
2) Prepare the rack: If your rack requires mounting ears or rails, attach them securely according to the manufacturer’s instructions. Ensure that the mounting points align with 19-inch rack standards to guarantee proper support and airflow paths.
3) Mount the unit: Gently slide the 3U enclosure into the rack and secure it with the provided screws or hardware. Verify that the front panel is easily readable and that the LCD remains visible for quick temperature checks during routine maintenance.
4) Connect power and wiring: Connect the two 12V DC power leads for the fans to a reliable power source. If the unit provides a dedicated power lead for the sensor or LCD, connect it per the included documentation. Route cables through cable management to maintain clean airflow and minimize tangling or obstruction.
5) Calibrate and verify: Power on the unit and confirm that the LCD displays ambient rack temperature and that both fans spin up and down in response to temperature changes. Validate that the blanking panel is properly seated to seal unused spaces, thereby ensuring optimal airflow and cooling efficiency.
6) Configure operational preferences: If the unit offers adjustable fan profiles or temperature setpoints, configure these settings to align with your data center’s thermal policies. Record baseline temperatures for critical channels and monitor trends over the first 24–72 hours to fine-tune performance.
7) Routine maintenance: Periodically inspect the fans for dust buildup, verify the integrity of connections, and confirm the blanking panel remains seated. Regular checks help maintain airflow efficiency and prolong the life of the cooling components.
This installation approach provides a clean, professional finish and ensures you maximize the benefits of real-time temperature monitoring, responsive cooling, and effective airflow management in your rack environment. The combination of a digital temperature sensor, LCD visibility, and two quiet fans makes it an ideal upgrade for data centers, edge facilities, and IT closets where performance and reliability are essential.
Frequently asked questions
Q: What is the primary benefit of this 3U digital temperature sensor with fans?
A: It provides precise temperature monitoring combined with automatic, responsive cooling. The LCD display shows real-time readings, helping you quickly identify hotspots and prevent thermal-related equipment issues, while the two 12V DC fans deliver targeted cooling where it’s needed most.
Q: How does the blanking panel improve cooling?
A: The blanking panel fills empty spaces in the rack to prevent hot air from leaking around equipment. This reduces recirculation, directs airflow through equipment, and improves overall cooling efficiency, which can lower energy use and maintain stable temperatures.
Q: Is this unit compatible with standard 19-inch racks?
A: Yes. The unit is designed for standard 19-inch racks and occupies 3U of vertical space, making it easy to integrate with most server and network rack configurations.
Q: Are the fans truly extra-quiet?
A: The fans are engineered for quieter operation relative to typical rack fans, reducing noise in data centers, server rooms, or office environments while still delivering effective cooling for high-density deployments.
Q: Do I need specialized tools or training to install this device?
A: Basic rack-mounting tools are typically sufficient. The installation steps are straightforward and designed for IT staff familiar with standard 19-inch racks. Always consult the user manual for any model-specific instructions or safety precautions.
With its integrated LCD display, dual 12V DC quiet fans, and a purpose-built blanking panel, the Tripp Lite by Eaton 3U Digital Temperature Sensor offers a comprehensive cooling and monitoring solution for professional data centers and network environments. This unit emphasizes intelligent thermal management, reliability, and ease of installation, making it a smart choice when upgrading existing racks or deploying new infrastructure. By combining real-time temperature visibility with responsive airflow control, it helps you maintain equipment performance, reduce the risk of thermal-related downtime, and extend the longevity of critical servers, storage devices, and networking gear. Whether you’re consolidating workloads in a dense environment or maintaining open racks for frequent maintenance, this 3U solution provides the right balance of monitoring accuracy, cooling efficiency, and user-friendly operation to support your IT objectives.
Customer reviews
Showing - Of Reviews