Description
Tripp Lite by Eaton 42U SmartRack Wide Standard-Depth Rack Enclosure Cabinet with Doors and Side Panels
Optimized for modern data centers, server rooms, and edge deployments, the Tripp Lite by Eaton 42U SmartRack Wide Standard-Depth Rack Enclosure Cabinet delivers uncompromising reliability in a broader footprint. This wide version, at 750 mm (29.5"), is designed to support high-density equipment installations where space efficiency, cable management, and easy access to front and rear equipment are critical. With doors and side panels included, it provides a secure, organized enclosure that helps maintain airflow, protect valuable IT assets, and simplify maintenance and upgrades. Whether you’re provisioning racks for servers, storage, networking, or mixed racks of mission-critical gear, this cabinet combines robust construction with practical features that promote efficient wiring, cooling, and scalability.
- Wide, high-density design for flexible layouts: The 750 mm (29.5") width expands interior space, enabling you to deploy higher-density configurations. This extra width makes it easier to route cables and install PDUs off to the sides, reducing clutter inside the rack and improving airflow. The broader footprint is ideal for modern equipment with larger front profiles, multi-port switches, blade servers, and dense storage arrays. By giving you more room to breathe, the enclosure supports rigorous IT workloads without forcing compromises on performance or access.
- 42U capacity for scalable IT deployments: With a full 42U of vertical space, this SmartRack enclosure accommodates a wide range of IT gear, from compact edge servers to heavier campus racks. The generous height supports multiple rack-mount devices in a single cabinet, simplifying cable management, power distribution, and future expansion. The enclosure is purpose-built to keep critical equipment organized and easy to service, which translates to reduced downtime and streamlined maintenance cycles.
- Standard-depth reliability with secure access: This enclosure is designed for standard-depth equipment, balancing depth with space efficiency in network rooms and data centers. The combination of durable construction, secure doors, and lockable side panels helps protect equipment from unauthorized access while maintaining convenient serviceability for administrators and technicians. The door and side panel assembly provides a clean, professional appearance and supports consistent cooling compared to open frameworks.
- Side-mounted cable management and PDU integration: A defining feature of the wide SmartRack is the ability to mount cable management accessories and PDUs off to the sides of the rack. By routing power, data, and cabling externally, you can minimize congestion inside the cabinet, improve airflow, and simplify service that involves swapping or upgrading components. This design is especially beneficial in environments with dense cabling or frequent changes to the device lineup, where quick access and tidy organization translate to real operational gains.
- Secure, ready-to-use enclosure with doors and side panels: The cabinet ships with doors and side panels, delivering a complete, ready-to-deploy enclosure for immediate installation. The included panels help contain dust and debris, safeguard sensitive equipment, and provide a professional, uniform appearance in data centers and rooms with stringent security or compliance requirements. The integrated enclosure supports predictable installation workflows, reduces risk during setup, and gives you a stable foundation for ongoing IT operations.
Technical Details of Tripp Lite by Eaton 42U SmartRack Wide Standard-Depth Rack Enclosure Cabinet with Doors and Side Panels
- U-Height: 42U
- Width: 750 mm (29.5 inches)
- Depth: Standard-depth enclosure
- Includes doors and side panels for secure enclosure
- Cable management and PDU mounting possible off to the sides of the rack
- Chassis and panel construction designed to support high-density equipment installations
how to install Tripp Lite 42U SmartRack Wide Standard-Depth Rack Enclosure Cabinet
Installing the Tripp Lite 42U SmartRack Wide Standard-Depth Rack Enclosure Cabinet begins with a careful planning phase. Assess your space to ensure the floor is level and capable of supporting the cabinet’s weight when fully loaded. Confirm the electrical infrastructure can accommodate the planned PDUs and power distribution requirements, and map out cable pathways that will keep front and rear access unobstructed. Next, verify that all components—doors, side panels, and any included hardware—are present and free of damage. A clean, organized working area will accelerate assembly and reduce the risk of missing parts during installation.
Position the enclosure in your designated slot, aligning it with floor mounting points or existing rack rails as required. Secure the cabinet to the floor or to adjacent racks according to the manufacturer’s guidelines to ensure stability and compliance with seismic or safety standards in your facility. With the cabinet secured, attach the doors and side panels to form a solid protective enclosure. Ensure that the latch mechanisms operate smoothly and that gaskets are seated correctly to minimize dust intrusion and improve thermal performance.
Plan your cable management and power distribution strategy before adding IT equipment. Install any side-mounted cable trays or vertical managers if your configuration calls for it, and route power and data cables to the rear of the cabinet in a clean, orderly manner. When you’re ready, begin mounting your IT devices using standard rack-mount rails or brackets, following manufacturer guidance for weight distribution and air-flow considerations. As you populate the cabinet, label cables and devices for future maintenance, and confirm that PDUs and power cables do not obstruct air inlets or outlets. Finally, close and secure the doors, perform a quick safety check, and verify that all equipment powers on correctly and remains within safe temperature ranges during initial testing.
Ongoing maintenance of the 42U SmartRack Wide enclosure focuses on keeping cabling tidy, ensuring doors remain securely closed, and inspecting seals and panels for wear. Periodic dusting and airflow assessments help maintain cooling efficiency—an essential factor when housing dense equipment in a wide cabinet. If you add or reorganize gear, revisit cable routing and PDU placement to preserve efficient airflow paths and minimize heat buildup. This practice not only extends the life of your equipment but also preserves performance and reliability across your IT infrastructure.
Frequently asked questions
-
Q: What makes the 750 mm wide SmartRack different from standard-width enclosures?
A: The wider 750 mm design provides additional interior space for high-density configurations, enabling easier side routing for cable management and PDU mounting while preserving front and rear access for maintenance and upgrades. -
Q: Does this enclosure include doors and side panels?
A: Yes. The cabinet ships with doors and side panels to form a secure, enclosed workspace for your IT equipment. -
Q: Is this cabinet suitable for data centers, network rooms, and edge deployments?
A: Absolutely. Its 42U capacity, wide footprint, and standard-depth design make it versatile for data centers, IT closets, network rooms, and edge locations that require scalable, organized rack space. -
Q: Can cable management and PDUs be mounted off to the sides?
A: Yes. The wider enclosure is specifically designed to accommodate side-mounted cable management solutions and PDU mounting to keep internal space clear and airflow optimal. -
Q: What installation considerations should I plan for?
A: Plan for a level floor, secure mounting, proper cable routing, and adequate ventilation. Allow space for expansion, label cables, and keep a maintenance pathway to front and rear access to facilitate future upgrades and servicing.
Customer reviews