Description
Tripp Lite IS1800HGDV Medical-Grade Isolator Dual-Voltage Transformer
The IS1800HGDV from Tripp Lite by Eaton delivers hospital-grade protection for sensitive electronics in patient-care environments. This dual-voltage isolation transformer combines safety, reliability, and flexible power configuration in a compact, rugged enclosure. With a full CAN/ES/IEC/EN 60601-1 medical-grade listing, it is purpose-built to safeguard clinical devices and IT equipment from power disturbances, transients, and grounding issues while fitting neatly into healthcare workspaces.
- Dual-voltage versatility: The transformer supports 115/230V operation and can be configured for step-up, step-down, or pass-through, enabling seamless adaptation to a variety of clinical power sources and equipment needs.
- Medical-grade protection: Listing to CAN/ES/IEC/EN 60601-1 ensures electrical safety, isolation, and performance in patient-care areas, helping facilities comply with stringent healthcare standards.
- Multiple outlets for centralized power: Eight IEC C13 outlets provide convenient central power distribution for monitors, infusion pumps, imaging devices, computers, and other critical equipment while preserving clean power delivery.
- High-quality isolation for equipment integrity: The IS1800HGDV uses a robust isolation transformer design to minimize electrical noise, prevent ground loops, and shield sensitive electronics from damaging transients and surges.
- Rugged, clinic-ready form factor: Built to endure demanding healthcare environments, the unit offers reliable uptime and straightforward integration into existing power infrastructure with a safe, medical-grade footprint.
Technical Details of Tripp Lite IS1800HGDV
- Model: IS1800HGDV
- Series: Isolator
- Voltage: Dual-Voltage 115/230V
- Power Capacity: 1800W
- Frequency: 50/60 Hz
- Inlet: C20
- Outlets: 8 x IEC C13
- Medical-Grade Listing: CAN/ES/IEC/EN 60601-1
- Configuration: Step-up, Step-down, or Pass-through
- Protection: Electrical isolation to protect connected equipment from line noise and transients
- Applications: Protection for clinical devices, IT gear, and other sensitive electronics in patient-care areas
How to install Tripp Lite IS1800HGDV
- Prepare the installation area: choose a stable, dry, and accessible location with adequate clearance for ventilation and heat dissipation. Keep the unit away from water sources and excessive dust common in some clinical settings.
- Confirm voltage configuration: verify whether your facility uses 115V or 230V supply and set the transformer mode accordingly (step-up, step-down, or pass-through) to match the equipment requirements. Follow the manufacturer’s labeling on the unit for the correct configuration.
- Connect the inlet: attach the C20 inlet to a properly rated power source that corresponds to the configured voltage. Ensure the power source is grounded and within facility electrical codes for medical devices.
- Distribute power to devices: plug medical monitors, pumps, workstations, and other sensitive equipment into the eight IEC C13 outlets. Do not connect devices exceeding the total rated load of 1800W to avoid overloading the transformer.
- Verify operation and safety: power on the IS1800HGDV and confirm that connected devices receive clean, stable power. Inspect for any signs of overheating, unusual noises, or abnormal behavior and consult maintenance if needed.
Frequently asked questions
- What is the purpose of the IS1800HGDV in a medical setting? It provides electrical isolation and voltage configuration to protect sensitive medical devices and IT equipment from power disturbances, ensuring safer operation in patient-care vicinities.
- Can the transformer operate at both 115V and 230V? Yes. The IS1800HGDV is a dual-voltage model designed to work with either 115V or 230V supplies, with configuration options for step-up, step-down, or pass-through.
- How many devices can be powered from this transformer? The unit offers eight IEC C13 outlets, with a total load limit of 1800W. Distribute power across devices to stay within this rating for safe operation.
- What kind of protection does it provide? It provides electrical isolation and suppression of noise and transients, helping prevent ground loops and protecting connected equipment from electrical disturbances common in clinical environments.
- Is it compliant with medical safety standards? Yes. The IS1800HGDV carries medical-grade listings including CAN/ES/IEC/EN 60601-1, ensuring safety and compliance for use near patients and healthcare equipment.
Customer reviews
Showing - Of Reviews