Tripp Lite by Eaton Isolator Series Dual-Voltage 115/230V 600W 60601-1 Medical-Grade Isolation Transformer, C14 Inlet, 6 C13 Outlets

Tripp Lite by EatonSKU: 5174761

Price:
Sale price$904.12

Description

Tripp Lite by Eaton Isolator Series Dual-Voltage 115/230V 600W Medical-Grade Isolation Transformer, C14 Inlet, 6 C13 Outlets

The Tripp Lite by Eaton Isolator Series Dual-Voltage Isolation Transformer is engineered for the demanding needs of patient-care environments. Its primary purpose is to safeguard sensitive medical and electronic equipment from power disturbances, mains noise, and transient events that can compromise performance and patient safety. In clinics, hospitals, and examination rooms where reliability matters, this medical-grade isolation transformer delivers clean, isolated power to essential devices while minimizing electrical interference that can affect readings, imaging, and monitoring systems. Designed with a focus on durability, ease of use, and clinical reliability, it stands as a dependable power conditioning solution for busy healthcare settings.

With dual-voltage capability, the unit supports both 115V and 230V input configurations, making it adaptable for international use and for facilities that operate across different power standards. The 600W power rating provides ample headroom for a range of medical devices and ancillary equipment, while the six IEC C13 outlets offer flexible distribution to multiple pieces of equipment without overcrowding a single power strip. The C14 inlet provides a straightforward connection point to standard hospital-grade power sources, and the overall design emphasizes safety, electrical isolation, and quiet, reliable operation in quiet patient-care spaces.

  • The transformer delivers robust protection for sensitive devices by providing galvanic isolation from the main power line, helping to minimize leakage currents and reduce electrical noise that can interfere with measurements and device performance in clinical settings.
  • Dual-voltage adaptability (115/230V) enables worldwide use and simplifies deployment in multi-region facilities, allowing institutions to standardize equipment with confidence regardless of local power standards.
  • Six C13 outlets give healthcare teams flexible power distribution for monitors, pumps, analyzers, imaging accessories, and other essential devices, reducing clutter and improving workflow in exam rooms and control areas.
  • The C14 inlet simplifies connection to standard hospital power infrastructure while maintaining a secure, compact footprint suitable for bedside carts, wall-mountable setups, and compact telemedicine stations.
  • Medical-grade construction and isolation technology are designed to support safe operation around patients and staff, helping to mitigate electrical disturbances that can compromise safety and equipment performance in medical environments.

Technical Details of Tripp Lite by Eaton Isolator Series Dual-Voltage 115/230V 600W 60601-1 Medical-Grade Isolation Transformer, C14 Inlet, 6 C13 Outlets

  • Input voltage: Dual-Voltage 115V / 230V
  • Power rating: 600W
  • Outlet configuration: 6 x IEC C13 outlets
  • Inlet type: IEC C14 inlet
  • Isolation/medical-grade design: Medical-grade isolation transformer suitable for patient-care environments
  • Series/model reference: Isolator Series by Tripp Lite (60601-1 designation noted in product title)

How to Install Tripp Lite Isolator Series Transformer

  • Place the unit on a sturdy, ventilated surface in a clean, dry area near the equipment it will serve; avoid exposure to liquids and extreme heat sources.
  • Connect the IEC C14 inlet on the transformer to the corresponding AC power source rated for the selected region (115V or 230V). Ensure the outlet and circuit can handle the anticipated load.
  • Set the input voltage to match your regional power standard if the dual-voltage configuration requires manual selection; verify the indicator settings before powering on.
  • Distribute power by plugging critical devices into the six IEC C13 outlets, taking care not to exceed the unit’s 600W rating and balancing load across outlets where possible.
  • Power on the transformer and monitor connected equipment for stable, clean power delivery; check for abnormal noises, overheating, or tripped breakers and adjust placement or load as needed.

Frequently asked questions

  • Q: What is the purpose of a medical-grade isolation transformer? A: It provides galvanic isolation between the hospital power grid and sensitive medical devices, reducing electrical noise, leakage currents, and transients that can affect performance and patient safety.
  • Q: How many outlets does this unit provide? A: The transformer offers six IEC C13 outlets, allowing flexible power distribution to multiple devices in clinical settings.
  • Q: Can this transformer be used internationally? A: Yes. Its dual-voltage design supports both 115V and 230V environments, enabling use across regions with different power standards when paired with appropriate input connections.
  • Q: What is the maximum load this unit can support? A: The unit is rated for up to 600W, making it suitable for a range of medical devices and ancillary equipment while maintaining safety margins in patient-care areas.
  • Q: How should facilities implement this transformer in their power plan? A: Install on a stable surface in a clean area, connect to the proper voltage source, monitor total load to stay within the 600W rating, and periodically inspect ventilation and connectors to ensure reliable operation.

Customer reviews