Description
Tripp Lite by Eaton OmniSmart 230V 350VA 225W CE/IEC 60601-1 Medical Grade Line-Interactive UPS with Built-In Isolation Transformer
In healthcare environments, clean, reliable power is non-negotiable. The Tripp Lite OmniSmart OMNIX350HG is engineered to protect critical medical equipment from voltage fluctuations, surges, and noise, while delivering isolation to help safeguard patients and sensitive electronics. This 230V medical-grade UPS combines line-interactive voltage regulation with a built-in isolation transformer and Faraday shield, providing comprehensive protection that aligns with CE and IEC 60601-1 standards.
Designed for bedside devices, monitors, and diagnostic equipment, the OMNIX350HG ensures stable power even in facilities with variable mains quality. By automatically correcting minor sags and transient voltages without drawing down the battery, it reduces wear on devices and minimizes downtime. When power loss occurs, the UPS seamlessly switches to battery power, keeping essential systems online for a safe orderly shutdown or intervention, depending on your configuration. For hospitals and clinics that demand patient safety and data integrity, this unit delivers predictable performance when it matters most.
Aside from protection, the unit's 350 VA / 225 W capacity is tuned for medical-grade loads, delivering clean, regulated output that helps prevent equipment resets, data loss, or misreadings triggered by poor power quality. The built-in isolation transformer provides galvanic isolation, dramatically reducing common-mode noise and protecting both medical devices and operators from electrical interference. This feature, combined with a Faraday shield, contributes to superior performance in environments where patient safety and data integrity are paramount. The result is a quieter, more reliable power foundation for essential clinical workflows, imaging suites, telemetry, and vital-sign monitoring equipment.
- Medical-grade line-interactive UPS with built-in isolation transformer and Faraday shield for full isolation and reduced electrical noise
- 230V AC input and output with CE/IEC 60601-1 compliance, designed for healthcare environments
- 350 VA / 225 W power capacity suitable for essential clinical equipment and monitors
- Intelligent monitoring with unattended shutdown capability to facilitate safe, automatic power-off procedures when needed
- IEC320 power inlet and outlets ensure compatible connections with standard hospital-grade devices
At the core of the OMNIX350HG is a design philosophy focused on reliability, patient safety, and ease of use. The unit integrates seamlessly into healthcare workflows, providing a quiet, compact footprint that fits beneath or beside critical equipment. The acoustic profile is minimal, helping maintain a calm clinical environment while it quietly protects devices. Because it leverages a line-interactive regulation approach rather than relying solely on battery inversion, the UPS can respond quickly to minor voltage variations, preserving battery life for longer events or outages. The result is less wear on connected devices, longer overall service life, and fewer disruptions in patient care scenarios.
What sets this model apart is the built-in isolation transformer with a Faraday shield that isolates the load from the incoming mains. This isolation not only protects vulnerable medical electronics from common-mode noise but also reduces potential ground loops that can cause patient-related safety concerns or measurement inaccuracies. In settings like imaging, anesthesia, telemetry, and vital-sign monitoring, such isolation can translate to more stable readings, fewer nuisance trips, and improved equipment longevity. The combination of isolation, regulation, and sophisticated monitoring helps healthcare facilities meet stringent power-quality requirements without adding excessive maintenance burdens. In addition, the unit’s clear front-panel indicators and straightforward controls make it easy for clinical staff to verify status during rounds or emergencies without interrupting patient care.
In addition to physical protections, the OMNIX350HG is engineered for intelligent power management. The UPS provides real-time status updates and alarms, accessible via front-panel indicators and compatible network or software-based monitoring tools. Unattended shutdown capability is particularly valuable for devices that require a controlled shutdown sequence at the end of battery runtime, preserving data integrity and ensuring patient safety when power events extend beyond a few seconds. The system's design also supports rapid recovery to normal operation as soon as mains power returns, reducing downtime and keeping critical workflows on track. Healthcare IT teams appreciate the predictable behavior of the unit during outages, allowing for reliable documentation and response planning in patient-care environments.
Healthcare facilities often face space constraints, and the OMNIX350HG addresses this with a compact, robust enclosure built to withstand the rigors of clinical environments. Durable construction, solid protection for outlets and connectors, and ease of maintenance contribute to a lower total cost of ownership. The medical-grade certification means that the equipment has been tested to meet safety and performance criteria required for use with non-life-support devices in clinical settings. It is important for hospitals, clinics, and home healthcare environments that require trustworthy, regulated power protection without overwhelming complexity. The OMNIX350HG also supports simple integration with existing power management ecosystems, enabling care teams to document protection coverage and maintain regulatory readiness with minimal effort.
Technical Details of Tripp Lite by Eaton OmniSmart 230V 350VA 225W CE/IEC 60601-1 Medical Grade Line-Interactive UPS with Built-In Isolation Transformer
- Model: OMNIX350HG (Tripp Lite by Eaton) - Medical-grade line-interactive UPS with built-in isolation transformer
- Input voltage: 230 VAC (50/60 Hz)
- Output voltage: 230 VAC, regulated with protection against sags and surges
- Capacity: 350 VA / 225 W
- Protection: Built-in isolation transformer with Faraday shield to provide full galvanic isolation and noise suppression
- Compliance: CE and IEC 60601-1 medical safety standards
- Connectors: IEC320 power inlet and IEC320 outlets suitable for hospital-grade devices
- Topology: Line-interactive UPS with automatic voltage regulation for efficient protection
- Monitoring: Integrated intelligent monitoring with alerts and unattended shutdown capability
- Environmental considerations: Compact, durable enclosure designed for clinical environments
How to install Tripp Lite by Eaton OmniSmart 230V 350VA 225W CE/IEC 60601-1 Medical Grade Line-Interactive UPS with Built-In Isolation Transformer
- Choose a stable, accessible location near the equipment that will be protected. Ensure adequate ventilation and space for service access and cable routing.
- Connect the UPS input to a dedicated 230V AC outlet using the IEC320 power inlet supplied with the unit. Avoid daisy-chaining from other devices to minimize electrical interference and ensure reliable operation.
- Plug protected devices into the IEC320 outlets on the UPS, prioritizing critical medical equipment and monitors. Do not overload the UPS beyond its 350 VA / 225 W rating to maintain protection integrity and battery runtime.
- Power on the UPS and verify the front-panel indicators. The unit should initialize with normal operation, regulating voltage and monitoring load conditions.
- Configure default settings as needed for your facility. If the UPS supports unattended shutdown, enable the appropriate options so that devices shut down safely when battery runtime is exhausted, preserving data and ensuring patient safety.
- Periodically test the system by simulating a mains outage to confirm smooth transition to battery power and to verify that critical devices remain operational during power events. Inspect connectors and vents for dust buildup and maintain a clean environment for optimal performance.
- Maintain awareness of battery service life. When replacement is needed, follow the manufacturer’s instructions for safe disposal and service, and replace according to the recommended maintenance schedule to sustain protection integrity.
Frequently asked questions
- What is the purpose of the Tripp Lite OmniSmart OMNIX350HG? It provides medical-grade power protection with line-interactive voltage regulation and a built-in isolation transformer to protect sensitive devices and maintain patient safety during mains fluctuations and outages.
- Is this UPS compliant with medical safety standards? Yes. The unit carries CE and IEC 60601-1 certification suitable for healthcare environments.
- What devices can it protect? Essential clinical equipment, monitors, and other non-life-support medical devices that require reliable power and isolation from mains disturbances.
- What is the expected runtime? Runtime varies with the connected load. At the rated 225 W, runtime is optimized for critical devices; lighter loads will extend runtime, while heavier loads shorten it.
- How does isolation benefit my setup? The built-in isolation transformer and Faraday shield reduce common-mode noise and ground-loop related issues, resulting in cleaner power and more stable readings from sensitive medical instruments.
- Does it offer unattended shutdown? Yes. The unit supports intelligent monitoring and unattended shutdown to help preserve data and ensure orderly shutdown procedures during extended outages.
Customer reviews
Showing - Of Reviews