Tripp Lite by Eaton SmartOnline 208/240V 20kVA On-Line UPS - Double Conversion, 18kW, N+1, 12U, Network Card Option, TAA Compliant

Tripp Lite by EatonSKU: 5258596

Price:
Sale price$11,540.72

Description

Tripp Lite by Eaton SmartOnline 208/240V 20kVA On-Line UPS - Double Conversion, 18kW, N+1, 12U, Network Card Option, TAA Compliant

The Tripp Lite by Eaton SmartOnline 208/240V 20kVA On-Line UPS is designed to protect mission-critical rack-mounted equipment from power disturbances that can cause damage, downtime, and data loss. This robust online UPS uses double-conversion topology to continuously purify power and deliver clean, regulated output to your servers, storage, and network devices. With an impressive 18kW output capacity and a high 0.9 power factor, it provides abundant headroom for today’s workloads and scalable growth for future demand. Built for enterprise environments, this unit emphasizes reliability, availability, and manageability, making it a cornerstone for data centers, colocation facilities, and remote IT rooms that demand unwavering uptime.

  • Double-conversion online topology delivers isolated, regulated output even during input voltage sags, spikes, and outages, ensuring uninterrupted operation of sensitive IT equipment.
  • 18kW of real power capacity (20kVA) supports dense racks of servers, storage, and networking gear, with room to expand as your infrastructure grows.
  • N+1 redundancy in a 12U rack-mount enclosure provides high availability, enabling maintenance or module replacement without interrupting critical loads.
  • Optional Network Card enables remote monitoring, event logging, SNMP integration, and graceful shutdowns, giving you centralized visibility and control over powered devices.
  • Designed for 208/240V input and output, with TAA compliance for government and enterprise procurement, suitable for North American data centers and enterprise networks.

Technical Details of Tripp Lite by Eaton SmartOnline 208/240V 20kVA On-Line UPS

  • Model: SmartOnline 208/240V 20kVA On-Line UPS
  • Topology: On-Line Double Conversion for precise, continuous output regulation
  • Capacity: 20kVA / 18kW with a high 0.9 power factor
  • Input Voltage: 208/240V AC; Frequency: Auto-sensing 50/60 Hz
  • Output Voltage: 208/240V AC
  • Redundancy: N+1 configuration to maximize availability
  • Rack Height: 12U rack-mount enclosure
  • Management: Optional Network Card for remote management and monitoring
  • Compliance: TAA compliant for eligible government and enterprise deployments

how to install Tripp Lite by Eaton SmartOnline 208/240V 20kVA On-Line UPS

Installing this UPS requires careful planning and adherence to electrical codes. Follow these general steps to install the unit in a standard data center rack or equipment room.

  • Plan the installation area in a secure, well-ventilated space with adequate clearance for airflow, cable routing, and maintenance access around the 12U enclosure.
  • Mount the UPS securely in a compatible rack using the supplied rails, ensuring proper weight distribution and stability for long-term operation.
  • Route and connect the 208/240V input feed to a dedicated electrical circuit with appropriate breakers and grounding per local codes; verify grounding integrity before powering the system.
  • Connect critical equipment to the UPS output distribution or outlets as defined in your load plan, ensuring the total connected load does not exceed the UPS’s 18kW rating.
  • If using the Network Card option, install the card in the designated management slot and connect to your management network; configure IP settings, SNMP communities, and alert thresholds as required.
  • Power up the unit, perform the initial self-test, check battery status, and confirm that the UPS is regulating output voltage within specification while communicating with your monitoring tools or management software.
  • Document the installation, including serial numbers, network card configuration, and maintenance procedures, to facilitate future servicing and audits.

Frequently asked questions

  • Q: What does N+1 redundancy mean for this UPS? A: N+1 redundancy means there is an extra module or component beyond the required capacity to keep critical loads powered even if a single module or component fails or requires maintenance, maximizing uptime.
  • Q: Can this UPS handle standard data center loads at 208/240V? A: Yes. It provides 208/240V output with a high 0.9 power factor, making it well-suited for enterprise servers, storage, and networking gear in North American facilities.
  • Q: Is there an option to monitor and manage the UPS remotely? A: Yes. There is an optional Network Card that enables remote monitoring, SNMP integration, and graceful shutdown control for connected devices.
  • Q: Is the unit compliant with government procurement requirements? A: Yes. The UPS is TAA compliant, making it eligible for U.S. federal and other government procurement where the Trade Agreements Act applies.
  • Q: What is the primary benefit of online double-conversion power protection? A: Online double-conversion provides continuous, clean, isolated power by converting incoming AC to DC and then back to AC, buffering the load from input disturbances and ensuring stable voltage, frequency, and waveform.

Customer reviews

(0)

0 Out of 5 Stars


5 Stars
0
4 Stars
0
3 Stars
0
2 Stars
0
1 Star
0


Showing - Of Reviews


You may also like

Recently viewed