Description
The SRCOLOKIT42U is a purpose-built colocation solution from Tripp Lite by Eaton that transforms a standard 42U SmartRack enclosure into a secure, dual-tenant space. Designed for data centers, server rooms, and network closets that require controlled access and efficient utilization of space, this kit partitions a single 42U rack into two independent 20U compartments. A sturdy divider panel is included to ensure clear separation between tenants, while independently lockable 21U doors replace the traditional front and rear doors for enhanced security and access control. This makes it ideal for colocation setups where two organizations share one rack without compromising on privacy or safety. If you’re looking to maximize existing rack capacity while maintaining professional-grade security, the SRCOLOKIT42U is engineered to deliver.
- Dual-tenant, 20U-per-side configuration: The 42U rack is effectively split into two distinct 20U compartments, enabling two separate users to house their equipment within the same enclosure. A robust divider panel is included to preserve separation, reduce crosstalk, and simplify cable management for each tenant. This arrangement helps you optimize space, streamline power distribution planning, and improve airflow control for both sides alike.
- Independent lockable doors for each compartment: The traditional front and rear doors are replaced by two independently lockable 21U sections. With separate access points, each tenant can be granted or restricted entry without impacting the other side. This design enhances security, reduces risk of unauthorized access, and supports compliant access control policies in shared data environments.
- Maintains standard 42U rack compatibility with SmartRack ecosystems: Built to integrate seamlessly with existing Tripp Lite SmartRack 42U enclosures, the SRCOLOKIT42U preserves the familiar 19-inch rack rails and mounting patterns. It preserves the structural integrity and compatibility you rely on in data centers, while unlocking new possibilities for multi-tenant deployments within a single chassis.
- Includes essential components for quick deployment: In addition to the divider panel and dual doors, the kit provides the hardware and mounting accessories necessary to install the colocation configuration with minimal downtime. The result is a faster path from unpacking to a secure, multi-tenant operating environment, allowing you to reallocate floor space with confidence and clarity.
- Designed for secure, scalable, and cost-efficient hosting: By enabling two distinct users to share one 42U rack, the SRCOLOKIT42U helps data centers and facilities optimize footprint, reduce capital expenditures, and improve asset utilization. The combination of partitioned space, robust access control, and compatibility with existing SmartRack components makes this kit a practical solution for colocation, hybrid cloud integrations, or multi-tenant data hall strategies.
Technical Details of SRCOLOKIT42U
- Model and purpose: Tripp Lite by Eaton SmartRack Colocation Kit for 42U Rack Enclosures, SRCOLOKIT42U. Converts a single 42U enclosure into two independently accessible 21U-fronted compartments with a central divider to create two distinct spaces.
- Compartment configuration: Two 20U compartments for two users, separated by a divider panel. This enables clean separation of equipment, cabling, power distribution, and cooling paths for each tenant while sharing a common chassis.
- Doors and access control: Front and rear doors are replaced by independently lockable 21U door sections, providing selective access to each tenant’s space without cross-access.
- Compatibility: Designed for standard 42U SmartRack enclosures and compatible with the typical 19-inch rack-mount hardware used in data centers and server rooms.
- Construction and finish: Built from rugged steel with a durable finish suitable for data center environments, delivering long-term resilience under recurring access and cable activity.
- Divider panel: Included divider panel ensures a clean, professional separation between the two compartments and supports organized cabling and airflow management for each side.
- Installation considerations: The kit is intended to be installed by qualified personnel familiar with rack mounting, weight distribution, and access-control requirements. The design aims to minimize downtime while preserving the integrity of the existing enclosure’s structure.
- Security and compliance: By allowing independent access for two tenants, the SRCOLOKIT42U supports multi-tenant security models, audits, and access-control policies necessary in shared data environments.
- Scalability and ROI: The colocation approach enables organizations to maximize existing assets, reduce the need for additional racks, and improve facility utilization—often translating into a faster return on investment and a more flexible data-center footprint.
- Accessory inclusion and support: As part of the SmartRack ecosystem, this kit integrates with Tripp Lite/Eaton support channels and can be paired with compatible power distribution, cable management, and cooling solutions to further optimize per-tenant performance.
How to install SRCOLOKIT42U
Installing the Tripp Lite SRCOLOKIT42U in a compatible 42U SmartRack enclosure is a straightforward process when performed by trained technicians. The procedure leverages the existing mounting framework while adding the divider, independent doors, and required hardware to create two secure, usable spaces for separate tenants. The following high-level steps outline a practical approach to installation:
- Prepare the enclosure: Ensure the 42U rack is empty or contains only non-conflicting components. Verify that the rack is level, structurally sound, and located in a secure area with appropriate environmental controls (temperature, humidity, and airflow).
- Remove original doors (if applicable): If the existing front and rear doors are in place, remove them in accordance with manufacturer guidelines to reveal the 42U interior ready for the colocation kit integration. Follow proper safety procedures to manage door weights and fasteners.
- Install the divider and partition hardware: Position the divider panel within the rack to establish two 20U compartments. Secure the divider using the supplied hardware to ensure a stable, vibration-resistant boundary between the two sides.
- Attach the independently lockable doors: Install the two 21U door sections on the corresponding sides of the rack. Verify that each door closes securely and that the locking mechanisms engage properly. Test both compartments for reliable operation and ensure access hardware aligns with tenant needs.
- Route cables and configure power: Begin cabling and power distribution planning for each compartment. Use solid cable management practices, including separate cable managers or channels for each tenant, to minimize interference and improve airflow. Confirm that power distribution units (PDUs) are appropriately sized for each side’s equipment and that both sides meet electrical code requirements.
- Perform security and functional checks: After assembly, perform a thorough check of all locks, latches, and panels. Confirm that each compartment can be accessed independently by authorized personnel only. Validate that the divider remains stable under normal operation and that there is no unintended contact between equipment on opposite sides.
- Document and label: Document the final configuration, including door access credentials, compartment boundaries, and any tenant-specific cabling maps. Label both sides clearly to support future maintenance, audits, and tenant onboarding.
Frequently asked questions
Q: What is the SRCOLOKIT42U designed to do?
A: It converts a standard 42U rack into a dual-compartment colocation solution, enabling two tenants to share one enclosure with independently lockable access and a divider panel for clear separation.
Q: How many users can occupy the rack after installation?
A: Two users, each occupying a 20U compartment, with a central divider ensuring privacy and organization.
Q: Does the kit include the divider panel?
A: Yes, a divider panel is included to physically separate the two compartments and help with cable management and airflow control.
Q: Are the doors independently lockable?
A: Yes, the front and rear are replaced by two independently lockable 21U doors, giving each tenant secure, controlled access.
Q: Is this kit compatible with all 42U SmartRack enclosures?
A: It is designed for standard 42U SmartRack enclosures, and it integrates with the existing 19-inch rack mounting framework to preserve compatibility and ease of use.
Q: What about installation time and expertise?
A: Installation is typically performed by qualified personnel familiar with rack systems and data-center security practices. The process is designed to minimize downtime and maximize the benefit of a multi-tenant configuration.
Q: Can I scale beyond two tenants later?
A: The SRCOLOKIT42U is optimized for two tenants within a single 42U rack. For more tenants or larger multi-tenant scenarios, you may consider additional racks or alternative modular colocation solutions from the SmartRack family.
Q: Does this kit affect cooling or airflow?
A: The divider panel and compartment separation are designed to help manage airflow. To optimize cooling, pair the kit with appropriate cable management, airflow-directing accessories, and properly rated PDUs and cooling solutions tailored for each compartment’s equipment load.