Description
Vertiv Edge UPS 3000VA 2700W 230V 2U Line Interactive AVR Tower/Rack Mount
The Vertiv Edge UPS 3000VA (2700W) at 230V is engineered to safeguard critical server and networking equipment in distributed and edge IT deployments. With a versatile 2U convertible rack/tower form factor, this UPS delivers reliable uptime and protection from power disturbances—spikes, swells, and brownouts—that can damage hardware, interrupt operations, or compromise data integrity. Designed for edge environments, data closets, telecom cabinets, and small data centers, the Vertiv Edge blends robust electrical protection with flexible installation, making it a trusted backbone for demanding workloads. Its line-interactive AVR topology stabilizes voltage to provide clean, steady power to your gear, helping sustain performance during mains fluctuations and easing graceful shutdowns during outages. For IT teams, the Vertiv Edge UPS is a practical, scalable solution that protects investments in servers, switches, storage devices, and edge appliances while simplifying deployment and ongoing management.
- Reliable uptime for edge and distributed IT: guards critical servers, switches, storage, and network appliances against outages and damaging power events, reducing downtime and safeguarding data integrity.
- Flexible 2U rack/tower design: easily adapts to compact edge rooms or data closets, enabling seamless integration into existing racks or standalone mounting without sacrificing floor space.
- Line-interactive AVR for voltage stability: automatically corrects voltage sags and swells to deliver clean, regulated output to connected equipment, preserving performance during imperfect mains conditions.
- Ample power reserve for edge workloads: 3000 VA of apparent power and 2700 W of real power provide headroom for multiple servers, switches, and virtualization hosts along with peripheral devices.
- Intuitive management and compatibility: supports straightforward monitoring and graceful shutdown, and integrates with standard IT management workflows to keep administrators informed and in control.
Technical Details of Vertiv Edge UPS 3000VA 2700W 230V 2U Line Interactive AVR Tower/Rack Mount
- VA rating: 3000 VA
- Real power (W): 2700 W
- Input voltage: 230 V (single-phase)
- Output voltage: 230 V (auto-sensing)
- Topography: Line-Interactive with Automatic Voltage Regulation (AVR)
- Form factor: 2U rack/tower convertible
- Frequency: 50/60 Hz auto-sensing
- Battery type: Sealed lead-acid battery; replaceable
- Output connections: standard outlets configured for protected loads (exact count may vary by model)
- Protection features: overload protection, short-circuit protection, and surge suppression for connected equipment
- Monitoring and management: supports integrated monitoring and safe shutdown workflows compatible with common IT environments
How to install Vertiv Edge UPS 3000VA 2700W 230V 2U Line Interactive AVR Tower/Rack Mount
Installing the Vertiv Edge UPS is designed to be straightforward, whether you’re mounting in a rack or using it as a tower in a compact edge space. Follow these guidance points to ensure a secure, reliable setup that preserves equipment health and uptime:
- Choose installation orientation: determine whether the unit will sit in a rack or stand as a tower. The 2U form factor supports both configurations; use the included rack rails for rack mounting or place on a stable, level surface when used as a tower.
- Prepare the installation area: position the UPS in a well-ventilated location with adequate clearance for airflow and access to the outlets, input power, and management interfaces. Avoid enclosed or hot spaces to prevent overheating.
- Mounting and securing: if rack mounting, attach the included rails and secure the unit firmly in the rack. If used as a tower, ensure it rests on a non-slip surface with sufficient stability to prevent tipping during power events.
- Connect the load: plug your critical devices—servers, switches, storage, and edge appliances—into the UPS output outlets. Do not exceed the rated output (2700 W) to maintain protection and reliability.
- Connect the input power: connect the UPS input cable to a dedicated 230V AC power source. Ensure the circuit can handle the anticipated load to prevent nuisance tripping.
- Battery initialization and self-test: once connected, power on the UPS and allow the internal battery to initialize. Run a self-test to verify the battery and inverter are functioning correctly, typically via the management interface or front-panel indicators.
- Configure AVR and sensitivity: adjust Automatic Voltage Regulation (AVR) settings and voltage sensitivity if your environment requires tighter regulation or specific transfer thresholds. Ensure the AVR is active for typical edge voltages and that the transfer voltage aligns with your mains profile.
- Management and monitoring: connect any available management interfaces (USB, serial, or network adapters as supported) and install compatible software to monitor status, receive alerts, and trigger safe shutdown procedures during outages.
- Testing and validation: perform a controlled outage test to confirm the UPS responds as expected, providing battery-backed runtime to essential devices and executing the planned shutdown sequence when necessary.
- Maintenance considerations: schedule periodic battery checks and battery replacement as recommended by Vertiv. Maintain clear access to the unit for inspection and keep the area free of dust and obstruction to airflow.
Frequently asked questions
-
Q: What does 3000 VA / 2700 W mean for this Vertiv Edge UPS?
A: VA (volt-amps) represents apparent power, while watts reflect real power available to load. This model provides up to 3000 VA of apparent power and up to 2700 W of usable output, giving you room to protect multiple devices with headroom for power surges and short outages. -
Q: Is the Vertiv Edge UPS suitable for 230V networks and edge installations?
A: Yes. The unit is designed for 230 V operation, making it ideal for edge deployments, small data centers, and distributed IT environments where 230V supplies are standard. -
Q: Can I mount this UPS in a rack?
A: Absolutely. The 2U form factor is specifically designed for rack mounting, and the package includes mounting hardware to secure the unit in a standard equipment rack. It can also be used as a stable tower in appropriate spaces. -
Q: How does AVR improve power quality?
A: Automatic Voltage Regulation (AVR) corrects minor voltage fluctuations without drawing down the battery, delivering a steady output to connected devices. This helps prevent unnecessary battery wear and protects sensitive equipment from voltage sags and surges. -
Q: How long will the UPS keep devices running during an outage?
A: Runtime depends on the load and battery health. Heavier loads shorten runtime, while lighter loads extend it. For accurate runtime expectations, refer to the product specifications and use a load calculator with your connected equipment profile. -
Q: What management options are available?
A: The Vertiv Edge UPS supports standard IT management workflows, allowing monitoring, alerting, and graceful shutdown. Depending on the model, you may have USB, serial, or network-based management interfaces for integration with existing tools.
Customer reviews
Showing - Of Reviews