Description
Vertiv Geist Switched Rack PDU - 1U Horizontal, 30A, C13/C19, L6-30P
The Vertiv Geist Switched Rack PDU in a compact 1U horizontal form factor is built to transform how you power, protect, and manage critical IT equipment in data centers, server rooms, and network closets. With a 30A L6-30P input and a versatile blend of C13 and C19 outlets, this PDU delivers reliable, scalable power distribution for dense rack environments. Designed to integrate seamlessly with the Vertiv Geist management ecosystem, it provides granular control, proactive monitoring, and simplified cable organization—empowering you to optimize uptime, improve energy efficiency, and gain deeper visibility into your IT load. Whether you’re deploying high-density servers, storage devices, network switches, or edge appliances, this horizontal PDU keeps your gear running smoothly while helping you meet service-level objectives and budgetary goals.
- 1U Horizontal Form Factor: A space-saving design that fits neatly into any standard 19-inch rack, maximizing rack density without sacrificing accessibility or cable management. The horizontal orientation makes it easy to route cables cleanly and maintain a tidy, serviceable rack layout.
- 30A Input with L6-30P Connector: Rugged, industry-standard power input rated for demanding data-center workloads. The L6-30P plug supports reliable power delivery to high-demand IT gear while remaining compatible with common regional power configurations.
- Flexible Outlet Configuration (C13/C19): A versatile mix of C13 and C19 outlets accommodates a wide range of IT equipment—from servers and storage to switches and appliances—so you can consolidate power distribution in a single, tidy unit.
- Switched Power Distribution for Granular Control: Outlets that can be controlled remotely enable load shedding, orderly reboots, and rapid isolation of faults. This capability helps minimize downtime, protect critical hardware, and support proactive maintenance windows.
- Comprehensive Monitoring and Management Readiness: Designed to integrate with the Geist management platform, offering visibility into per-outlet status, current, voltage, and overall load trends. This insight supports DCIM workflows, capacity planning, and intelligent energy management across the rack.
Technical Details of Vertiv Geist Switched Rack PDU
- Form Factor: 1U Horizontal Rack PDU
- Input Power: L6-30P, 30A
- Outlets: C13 and C19 receptacles
- Configuration: Switched rack PDU with outlet-level control
- Mounting: 19-inch rack, horizontal orientation for versatile rack integration
How to install Vertiv Geist Switched Rack PDU
Installing the Vertiv Geist Switched Rack PDU is straightforward and designed to minimize downtime during deployment. Follow these general steps to integrate the PDU into your rack environment and begin realizing improved power distribution and management outcomes.
- Prepare the rack: Ensure your enclosure is a standard 19-inch rack with adequate vertical clearance for the 1U PDU. Confirm mounting rails are installed and accessible for secure attachment.
- Mount the PDU: Slide the PDU into the rack and align mounting holes with the rack rails. Use the provided screws to secure the unit firmly, taking care to avoid overtightening that could damage the chassis.
- Connect the input power: Refer to your regional electrical requirements and connect the L6-30P input plug to a suitable 30A power source. Verify the power source is stable and within the PDU’s operating specifications before energizing.
- Attach devices and cables: Connect IT equipment to the C13 and C19 outlets as needed. Route cables neatly to prevent obstruction to airflow and to simplify future maintenance or reconfigurations.
- Configure management and monitoring: If you’re using the Geist management ecosystem, connect the PDU to your network as directed in the Geist documentation. Enable outlet-level switching, set up alerts, and configure load monitoring to align with your DCIM or ITSM workflows. Power up the rack and perform a basic functional check to confirm outlet control and visibility are functioning as intended.
Frequently asked questions
Q: What outlets does the Vertiv Geist Switched Rack PDU use?
A: The PDU provides a combination of C13 and C19 outlets to support a broad range of IT equipment commonly deployed in data centers and server rooms.
Q: What is the input power specification?
A: The unit features a 30A L6-30P input connector, suitable for high-density rack environments and compatible with standard 208–230V data-center power configurations depending on regional wiring.
Q: Is the PDU switched?
A: Yes. This is a Switched Rack PDU, offering outlet-level switching to enable remote control, load shedding, orderly reboots, and fault isolation to reduce downtime and improve maintainability.
Q: Can I monitor energy usage and outlet status?
A: The Geist Switched PDU is designed for integration with Geist management tools, providing per-outlet status, current, voltage, and load trends to support proactive capacity planning and DCIM workflows.
Q: How does installation affect rack density?
A: With a compact 1U horizontal footprint, this PDU minimizes vertical space consumption while delivering robust power distribution. It helps optimize rack density by consolidating multiple power sources and reducing cable clutter when paired with compatible accessories and smart management.