VERTIV GXT5-03KPOD01 Power Distributor Unit

VERTIVSKU: 6797111

Price:
Sale price$559.84

Description

VERTIV GXT5-03KPOD01 Power Distributor Unit

The VERTIV GXT5-03KPOD01 Power Distributor Unit is a high-performance PDU designed to deliver reliable, scalable power distribution for modern IT environments. Built to support critical workloads in data centers, server rooms, and edge facilities, this compact unit combines rugged construction with intelligent power management features. It integrates seamlessly with Vertiv’s GXT5 family of UPS solutions, delivering clean, distributed power to racks of servers, storage devices, networking equipment, and other essential IT hardware. Whether you are expanding a growing data center, upgrading a colocation space, or optimizing an edge deployment, the GXT5-03KPOD01 PDU helps you maximize uptime, improve energy efficiency, and simplify electrical distribution across complex environments.

  • High-density, rack-mountable power distribution: Engineered for 1U and 19-inch rack installations, the GXT5-03KPOD01 provides scalable outlets and configurable configurations to support dense IT deployments. Its compact footprint preserves valuable rack space while delivering dependable power to multiple devices with minimal voltage drop and stable performance under load.
  • Flexible outlet configurations and regional compatibility: The PDU supports multiple outlet arrangements to match regional electrical standards. This flexibility is ideal for international deployments or hybrid facilities that require different outlet types, ensuring seamless compatibility with diverse server and networking gear without compromising safety or convenience.
  • Advanced protection and reliability: Designed to guard connected equipment against power anomalies, the GXT5-03KPOD01 includes overcurrent protection, surge suppression, and short-circuit safeguards. These protective features help minimize the risk of equipment damage during power disturbances and contribute to longer hardware lifecycles.
  • Intelligent monitoring and power management: With remote monitoring capabilities and integration options, you can track voltage, current, and outlet-level load in real time. The PDU supports management interfaces that enable alerts, reporting, and proactive power optimization, helping data centers operate more efficiently and with greater situational awareness.
  • Easy installation, maintenance, and serviceability: The GXT5-03KPOD01 is designed for straightforward installation, quick outlet access, and simple maintenance. Its rugged steel enclosure provides durability in demanding environments, while modular components simplify replacement and service without extended downtime.

Technical Details of VERTIV GXT5-03KPOD01 Power Distributor Unit

  • Model: GXT5-03KPOD01
  • Product type: Power Distributor Unit (PDU)
  • Power rating: Configurable to support critical IT loads; designed for consistent distribution across connected devices
  • Input voltage: 100–240 VAC (regional configurations available)
  • Output configuration: Multiple regional outlet configurations to match local standards and IT equipment requirements
  • Mounting: 1U rack-mountable, 19" rack compatible; optimized for dense data center racks and small-form-factor deployments
  • Protection: Overcurrent protection, surge suppression, short-circuit protection to safeguard connected equipment
  • Monitoring and control: Remote monitoring options, with integration through standard management interfaces for alerts and usage reporting
  • Material and construction: Robust steel enclosure with durable finish, designed for reliability in data centers and enterprise IT rooms
  • Certifications: Compliant with regional safety and electrical standards (UL, CE) as applicable to the installation region
  • Environmental notes: Designed to operate within standard data-center temperature and humidity ranges; supports fan-assisted cooling configurations where applicable

how to install VERTIV GXT5-03KPOD01 Power Distributor Unit

Installing the GXT5-03KPOD01 PDU begins with proper planning of your rack layout and electrical topology. Start by determining the most efficient power distribution strategy for your IT equipment, considering load balance, redundancy, and future growth. Verify that the rack space is clean, dry, and free of debris, and confirm that the selected location meets the required clearances for safe cable routing and heat dissipation. Ensure that the PDU’s regional electrical configuration matches the facility’s power source and that all safety protocols, including proper grounding, are observed before connection.

Step-by-step installation guidance:

1) Prepare the rack and mounting area: Inspect the rack rails, ensure they are level, and confirm that the 19" mounting depth accommodates the PDU’s enclosure. Align the PDU with the rack’s vertical mounting holes, and secure it using appropriate screws and rack hardware. Confirm that there is sufficient clearance for cable management and adequate airflow around the unit.

2) Connect to the power source: Attach the PDU’s input power cable to a suitable circuit that matches the unit’s input voltage specification. Use appropriate circuit protection (breaker or fuse) in accordance with local electrical codes. If your installation requires redundant power, position the PDU in the approved path for alternative feeds while maintaining compliance with safety and clearance guidelines.

3) Route and connect IT devices: Plan a clean, organized cabling scheme that minimizes tangling and reduces heat buildup. Connect servers, storage, and networking devices to the PDU outlets, ensuring that outlets are not overloaded beyond their recommended load rating. Consider distributing high-demand devices across multiple outlets to balance the load and maintain stable power distribution.

4) Enable monitoring and management: If you are using remote monitoring, connect the PDU to your management network or interface as specified for the unit. Configure alert thresholds, SNMP or Modbus settings, and web-based access if available. Validate that the PDU is reporting current, voltage, and outlet-level load accurately, and set up alarms for abnormal conditions such as overcurrent or temperature excursions.

5) Confirm operation and safety: Power on connected devices and confirm normal boot sequences. Check for any warning indicators on the PDU interface or management console. Confirm that surge protection and overcurrent features are functioning as expected. Perform a basic load test to verify that the distribution remains stable under peak conditions and that monitoring tools reflect realistic consumption data.

6) Documentation and ongoing maintenance: Record the PDU configuration, outlet mapping, and monitoring credentials for future reference. Schedule periodic inspections to ensure connections remain tight, look for signs of wear, and verify that fans and cooling pathways remain unobstructed. Regularly review monitoring dashboards to identify aging equipment, optimize energy usage, and plan for timely replacements when necessary.

The GXT5-03KPOD01 PDU is designed to integrate with Vertiv’s broader power protection ecosystem, enabling centralized visibility, streamlined asset management, and proactive risk mitigation. By combining reliable electrical distribution with intelligent monitoring, this unit supports higher uptime, improved energy efficiency, and simplified facility operations across diverse IT environments.

Frequently asked questions

  • Q: What is a Power Distributor Unit (PDU) and why do I need one?
    A: A PDU distributes electrical power from a single source to multiple IT devices within a rack. It helps manage loads, protects equipment with surge and overcurrent protections, and enables monitoring and control to optimize energy use and uptime.
  • Q: Is the GXT5-03KPOD01 compatible with other Vertiv products?
    A: Yes. The GXT5-03KPOD01 is designed to integrate with Vertiv’s power protection ecosystem, including Liebert GXT5 UPS systems and related management tools, to provide cohesive power reliability and monitoring.
  • Q: Can this PDU handle international power configurations?
    A: The unit offers configurable input and outlet configurations to align with regional electrical standards, making it suitable for multinational deployments or facilities with mixed electrical requirements.
  • Q: What kind of monitoring is available?
    A: Remote monitoring capabilities are supported, typically including load, voltage, current, and outlet-level status via standard management interfaces (such as SNMP or Modbus) and potentially a web interface for easy access.
  • Q: How do I maintain the GXT5-03KPOD01 PDU?
    A: Regular maintenance includes inspecting connections, verifying that protective devices are functioning, cleaning dust from the enclosure, and reviewing monitoring alerts. Periodic load testing helps ensure reliability under peak demand.
  • Q: What safety certifications does this PDU carry?
    A: The unit adheres to regional safety and electrical standards (UL, CE) as applicable to the installation region, ensuring compliance with industry requirements for data-center-grade equipment.

Customer reviews

(0)

0 Out of 5 Stars


5 Stars
0
4 Stars
0
3 Stars
0
2 Stars
0
1 Star
0


Showing - Of Reviews