Description
Vertiv Liebert GXT3 1000VA UPS — Mini-Tower Power Protection (GXT3-1000MT120)
The Vertiv Liebert GXT3 1000VA UPS in the compact Mini-Tower form factor is designed for demanding microcomputers and sensitive equipment that require pristine, uninterrupted power. This true online, double-conversion UPS continually conditions and stabilizes output voltage, delivering a clean sine wave even in the face of outages, sags, surges, and fluctuating utility power. With its UL/c-UL listing, reliable performance, and easy installation, the GXT3-1000MT120 keeps critical devices protected, workloads uninterrupted, and data integrity intact in small offices, home offices, and compact server rooms.
- True online, double-conversion protection: The GXT3 operates as a true online UPS, constantly converting incoming AC power to DC and back to a clean, regulated AC sine wave. This continuous conditioning isolates connected equipment from utility irregularities, preserving data integrity, preventing unexpected reboots, and ensuring consistent performance for sensitive devices such as modern workstations, NAS storage, and small servers.
- Compact mini-tower design with safety listings: The mini-tower footprint fits neatly on a desk or under a workspace, delivering robust power protection without dominating the space. It carries UL and c-UL listings, providing confidence in safety and compliance for commercial and residential installations alike.
- Automatic Voltage Regulation (AVR) and surge protection: AVR corrects common voltage fluctuations automatically, reducing unnecessary battery wear and extending runtime when mains voltage swings are minor. Built-in surge protection and EMI/RFI filtering shield attached equipment from spikes and electromagnetic interference, delivering stable, high-quality power to critical loads.
- Reliable battery backup with serviceability options: The GXT3 features sealed, replaceable battery cartridges designed for straightforward maintenance. When the utility power fails, the UPS seamlessly switches to battery power, giving you time to save work, perform graceful shutdowns, and avoid data loss. In many configurations, battery packs can be serviced or swapped with minimal downtime, preserving uptime for essential operations.
- Easy monitoring, management, and connectivity: A front-panel display and status indicators provide at-a-glance feedback on input/output voltage, load, battery charge, and operational mode. USB connectivity enables safe software-controlled shutdowns, event logging, and graceful power-downs for connected workstations and servers, while audible alarms alert you to conditions that require attention.
Techncial Details of Vertiv Liebert GXT3 1000VA UPS
- Model: GXT3-1000MT120
- Topology: True online, double-conversion UPS designed to continuously condition and regulate output voltage
- Output voltage: 120 VAC nominal (US power standard)
- Input voltage: 120 VAC nominal (typical 120V input in the target market)
- Form factor: Mini-Tower, compact footprint suitable for desktop or shelf placement
- Safety: UL and c-UL Listed for compliance and safety in consumer, office, and commercial environments
- Protection features: Pure sine wave output, AVR to regulate minor voltage fluctuations, surge protection, and EMI/RFI filtration for sensitive electronics
- Battery system: Sealed lead-acid, replaceable battery cartridges for straightforward maintenance and extended service life
- Management and interfaces: USB connection for safe shutdown and software integration; front-panel indicators and status display
how to install Vertiv Liebert GXT3 1000VA UPS
Installing the Liebert GXT3 1000VA UPS is designed to be straightforward for both home offices and small business environments. Follow these practical steps to ensure safe, reliable operation and optimal performance from day one.
- Choose a stable, ventilated location: Place the UPS on a flat surface away from heat sources, direct sunlight, and excessive dust. Leave adequate clearance around vents to promote airflow and prevent overheating during operation or battery charging. Avoid stacking heavy devices on top of the UPS, which could affect stability and airflow.
- Position for accessibility: Ensure you can reach the power switch, USB port, and any service panels easily. If your setup requires wall mounting or shelf placement, follow the manufacturer’s guidelines for mounting and weight limits.
- Connect the loads: Start by connecting the most critical devices—servers, routers, switches, network storage, or workstations—to the UPS outlets. Reserve noncritical peripherals for non-switched outlets, if available, to maximize battery runtime for essential equipment during an outage.
- Connect to the mains for charging: Plug the UPS into a dedicated 120 VAC outlet. Allow the battery to begin charging immediately. It’s recommended to let the battery charge for several hours before relying on it for critical loads, especially after first install or after a full discharge.
- Power on and configure: Turn on the unit and check the front-panel indicators. Use the USB connection to link to your computer or server and install compatible shutdown software if you rely on automatic data preservation. Configure any preferred alarm thresholds, voltage regulation settings, and notification options in the software or through the front-panel menu if available.
- Test the system: Perform a controlled power-down test by simulating a power interruption to verify that connected devices gracefully shut down and that the UPS transitions smoothly to battery power. This helps confirm that your backup plan is working as intended.
- Maintain and monitor: Periodically inspect battery health, run self-tests if supported, and review event logs. Replace the battery cartridges as recommended by the manufacturer to maintain peak performance and reliable runtime.
Frequently asked questions
- What is the Vertiv Liebert GXT3 1000VA UPS designed to protect? The GXT3-1000MT120 is built to safeguard microcomputers, network equipment, storage devices, and other sensitive electronics from power quality issues, outages, and transients. Its true online, double-conversion topology delivers clean, stable power to maintain data integrity and device reliability even when the utility grid is unstable.
- What is the difference between online (double-conversion) and standby or line-interactive UPS models? Online (double-conversion) UPS systems continuously convert incoming AC to DC and back, providing uninterrupted, clean sine-wave power regardless of utility conditions. This eliminates voltage sags, swells, and harmonic distortions. Standby or line-interactive UPS units switch to battery power only after a detected outage or severe disturbance, which can result in momentary power gaps for sensitive equipment.
- Can I extend runtime or protect more devices with this UPS? Yes. Runtime can be extended by adding compatible battery packs and by distributing loads across multiple outlets. For longer runtimes, an expanded protection plan with additional battery options may be appropriate, and you can use power management software to optimize shutdown sequences and conserve energy during an outage.
- Is the battery replaceable, and how do I maintain it? The Liebert GXT3 uses replaceable sealed lead-acid battery cartridges designed for serviceability. When battery health declines, swapping in a fresh cartridge restores runtime and reliability. Regular battery inspections and following manufacturer guidelines for replacement intervals help ensure consistent performance.
- How do I monitor and control the UPS? Use the USB connection to link the GXT3 to a computer or server and install the corresponding shut-down software. This software enables automatic safe shutdown, event logging, and notification of power events. Front-panel indicators provide quick status at a glance, and audible alarms alert you to issues requiring attention.
Customer reviews