Vertiv Liebert GXT5 External Battery Cabinet - 3000VA/72V|2U

LiebertSKU: 5565477

Price:
Sale price$1,160.86

Description

Vertiv Liebert GXT5 External Battery Cabinet - 3000VA/72V|2U

The Vertiv Liebert GXT5 External Battery Cabinet is a purpose-built, hot-swappable lead-acid battery solution designed to significantly extend the runtime of Liebert GXT5 UPS systems. Engineered to work seamlessly with the Liebert GXT5-3000LVRT2UXL, this external cabinet adds scalable power resilience for data centers, server rooms, and critical network closets. Its compact 2U footprint packs a robust 72V battery bank, delivering reliable backup power when it matters most and ensuring business continuity even during extended outages. Built for easy maintenance and rapid battery replacement, this cabinet empowers administrators to optimize uptime without sacrificing space or efficiency.

  • Seamless integration with Liebert GXT5-3000LVRT2UXL: The External Battery Cabinet is designed to pair perfectly with the Liebert GXT5 line, enabling a cohesive, scalable defense against power interruptions while preserving the compact footprint of your rack setup.
  • High-capacity 72V lead-acid battery bank: This cabinet houses a robust 72V battery system, providing substantial runtime extension to support critical loads during outages and sudden supply fluctuations.
  • Hot-swappable batteries for minimal downtime: The battery modules are designed for quick replacement without powering down the UPS, reducing maintenance windows and keeping your IT equipment protected during service.
  • 2U rack-mount enclosure for space efficiency: The slim 2U design fits neatly in standard 19-inch racks, allowing you to maximize data-center floor space while expanding energy resilience.
  • Maintenance-friendly design: Easy access to battery modules, thoughtful cable routing, and clear labeling simplify routine checks, battery swaps, and system health monitoring.

Technical Details of Vertiv Liebert GXT5 External Battery Cabinet - 3000VA/72V|2U

  • Model: Liebert GXT5 External Battery Cabinet
  • System compatibility: Designed for use with Liebert GXT5-3000LVRT2UXL UPS models
  • Power rating: 3000VA (apparent power) backup capacity when paired with the compatible UPS
  • Battery bank: 72V DC lead-acid configuration
  • Enclosure height: 2U rack-mount form factor
  • Enclosure type: External, hot-swappable battery cabinet for rapid maintenance
  • Mounting: 19-inch rack compatibility with standard rack rails
  • Maintenance: Hot-swappable design enables battery replacement without shutting down connected equipment

How to install Vertiv Liebert GXT5 External Battery Cabinet

Before you begin, verify that the Liebert GXT5 UPS is powered down and that all safety procedures for handling electrical equipment are followed. Ensure you have the appropriate mounting rails, cables, and documentation from Vertiv for your specific model configuration. The steps below describe a typical installation workflow for adding the external battery cabinet to a compatible Liebert GXT5 system.

Step 1: Prepare the rack and cabinet

Confirm there is a clear 2U space in your 19-inch rack for the external battery cabinet and that adjacent components will not obstruct airflow. Keep the area around the cabinet well-ventilated and free of dust or debris that could affect airflow or battery health. Inspect the cabinet and all hardware to ensure there are no transport-related damages from shipping.

Step 2: Mount the cabinet in the rack

Slide the external battery cabinet into the designated 2U rack space and secure it to the rack rails using the supplied mounting hardware. Ensure the cabinet is level and firmly fastened to prevent vibrations or movement during operation. Maintain proper clearance for cable connections and service access.

Step 3: Connect the cabinet to the Liebert GXT5 UPS

Connect the external battery cabinet to the Liebert GXT5 UPS using the manufacturer-recommended interconnect cables. Follow the wiring diagram accompanying your unit to ensure correct polarity and secure terminations. Do not power the UPS until all connections are verified and tightened as per the manual.

Step 4: Configure and verify

Power on the Liebert GXT5 UPS and allow the system to initialize. Use the back-panel indicators or the USB/serial management interface to confirm the external cabinet is recognized and reporting its status correctly. Run a basic battery health check or a battery test to validate proper operation and conditioning cycles.

Step 5: Test the integrated system under load

With load connected to the UPS, perform a controlled outage test to confirm the extended runtime provided by the external cabinet. Observe the UPS behavior, alarm states, and runtime calculations to ensure the system meets your recovery objectives. Document the test results and adjust maintenance schedules as needed to maintain peak performance.

Maintenance notes: Regularly inspect the cabinet’s venting, battery modules, and interconnects. Schedule battery health checks in accordance with your organization’s maintenance policy to ensure longevity and reliability. If you notice any unusual heat, swelling, or warning indicators, contact Vertiv support for guidance and potential battery module replacement.

Frequently asked questions

  • Q: What UPS models is the Liebert GXT5 External Battery Cabinet designed to accompany? A: It is designed to work with Liebert GXT5-3000LVRT2UXL UPS models to provide extended runtime and enhanced resilience against outages.
  • Q: Can the external battery cabinet be installed without powering down the UPS? A: Yes. The hot-swappable battery design allows battery replacement without shutting down the UPS, minimizing downtime.
  • Q: What is the primary benefit of adding this external cabinet? A: The cabinet significantly extends runtime for critical systems, improves uptime during extended outages, and enables scalable resilience without occupying extra floor space.
  • Q: How do I know when a battery needs replacement? A: Use the UPS management interface to monitor battery health indicators, voltage, and capacity. If the system reports degraded health or your runtime is shorter than expected, replace the affected battery modules following the manufacturer’s guidelines.
  • Q: Is there a recommended maintenance schedule for the cabinet? A: Yes. Follow your organization’s battery maintenance policy, conduct periodic visual inspections, test battery health, and perform routine connection checks to ensure ongoing reliability.