Description
Vertiv Liebert GXT5 UPS - 10kVA/10kW 230V Online Rack Tower Energy Star
The Vertiv Liebert GXT5 UPS delivers premium, always-on power protection for critical equipment in centralized data centers and edge deployments. This online double-conversion UPS provides clean, conditioned power with unity power factor, ensuring that all connected loads receive full-tilt power without derating. With a 10 kW capacity at 230 V, the GXT5 is designed to safeguard servers, networking gear, storage, and other mission-critical devices against outages, sags, surges, and other disturbances common in edge and enterprise environments. Built for reliability and efficiency, the GXT5 brings enterprise-grade protection to a broad range of deployments while maintaining a compact footprint that supports rack or tower configurations. Energy Star certification underscores its focus on low total cost of ownership, reduced energy consumption, and cooler operation. Whether you’re protecting a small data center, a telecom edge site, or a distributed IT cabinet, the Liebert GXT5 combines rugged hardware with intelligent management to keep your applications available, data secure, and operational costs in check.
- High-capacity protection: 10 kVA / 10 kW online UPS provides scalable, continuous power conditioning for essential IT equipment, enabling stable operation during outages and the full spectrum of power disturbances.
- Online double-conversion topology with unity power factor: Delivers clean, ride-through power to loads with a 1.0 power factor, maximizing usable load capacity and reducing derating for tighter, more efficient deployments.
- Energy Star certified for efficiency: Engineered to minimize energy consumption and heat generation, helping lower operating costs and cooling requirements in centralized or edge environments.
- Flexible form factor for rack and tower deployments: Designed to fit both rack-mounted cabinets and standalone towers, enabling seamless integration into a variety of data-protection architectures.
- Robust protection and scalable runtime: Built to endure demanding environments with reliable battery management, hot-swappable battery options, and the ability to expand runtime with external battery cabinets as needs grow.
Technical Details of Vertiv Liebert GXT5 UPS - 10kVA/10kW 230V Online Rack Tower Energy Star
- Topology: Online double-conversion ensures continuous output power with near-perfect voltage regulation and excellent isolation from input disturbances.
- Rated power: 10 kVA / 10 kW, suitable for protecting mid-range data centers, edge deployments, and critical IT racks.
- Input/Output voltage: 230 V (standardized for global data centers and regional IT environments using 230 V power distribution).
- Power factor: Unity (1.0) on output, maximizing usable capacity for connected loads.
- Form factor: Rack/Tower adaptable to varied installation footprints, offering flexible deployment in dense data centers or compact edge cabinets.
- Energy efficiency: Energy Star certified; optimized for reduced energy use without compromising protection or performance.
- Remote management: Supports standard monitoring and management interfaces for proactive maintenance and status reporting.
- Battery design: Efficient battery management with options for scalable runtime through external battery modules to meet evolving protection needs.
How to install Vertiv Liebert GXT5 UPS
- Plan your installation area by selecting a well-ventilated, level surface with adequate clearance for airflow, service access, and cable routing. Confirm the floor can support the UPS weight and that the location is within reach of the main input power and critical load circuits.
- Choose between rack-mount or tower placement based on your enclosure strategy. If rack-mounting, use the manufacturer-approved mounting kit and secure the unit to ensure stable operation and safe maintenance access.
- Commission the input power connection to a dedicated distribution circuit that matches the 230 V input specification. Verify circuit protection and ensure the installed wiring meets local electrical codes and the UPS’s grounding requirements.
- Install or connect the battery subsystem. If you’re using external batteries, connect them according to the user manual, verify proper battery polarity, and allow any required battery initialization or charge time before first use.
- Position critical loads on the UPS output outlets or via a managed outlet strip as recommended. Separate essential IT equipment from non-critical devices to maximize uptime for the most important systems.
- Power on the system and perform an initial self-test to verify normal operation. Use the built-in controls or the network-management interface to configure basic settings, alarm thresholds, and notification preferences.
- Configure power management software or a compatible remote monitoring solution to receive real-time status, automatic shutdown commands, energy usage data, and alerts. Schedule periodic self-tests and battery health checks to maintain peak readiness.
Frequently asked questions
- What does the Vertiv Liebert GXT5 protect, exactly? It protects critical IT equipment such as servers, network switches and routers, storage devices, and edge compute nodes from power outages, sags, surges, and other disturbances by providing clean, conditioned power with continuous operation.
- Is the GXT5 Energy Star certified? Yes. The unit is Energy Star certified, reflecting its efficiency-focused design to reduce energy consumption and cooling requirements while delivering reliable power protection.
- Can I expand runtime if I need more backup power? Yes. The GXT5 supports scalable runtime through external battery cabinets, allowing you to extend backup time as your load or uptime requirements grow.
- Is rack mounting supported, and can it be used in edge environments? Absolutely. The GXT5 is designed for both rack and tower deployments, making it suitable for centralized data centers and edge locations where compact, reliable protection is essential.
- How should I maintain the UPS and batteries? Regular maintenance includes periodic self-tests, battery health checks, and firmware or software updates when available. Battery replacement should be performed by qualified personnel following the manufacturer’s maintenance guidelines to ensure safety and continued protection.