Description
Vertiv Liebert GXT5 UPS - 4900VA/4600W 208V Online Rack/Tower Energy Star
The Vertiv Liebert GXT5 UPS delivers robust, uninterrupted power for critical IT equipment, offering online, double-conversion protection in a compact rack/tower form factor. At 4900 VA / 4600 W and designed for 208V environments, it safeguards servers, networking gear, storage devices, and edge computing nodes from outages, surges, sags, and other disturbances. Energy Star certified for energy efficiency, this UPS suits both centralized data centers and edge deployments where reliable power quality matters most. With Liebert engineering, you gain scalable protection, quiet operation, and a dependable backbone for your business-critical workloads, ensuring uptime and data integrity even during power events.
- Online double‑conversion topology: Delivers clean, isolated, continuous power with zero transfer time, protecting sensitive equipment from outages and power disturbances.
- 4500+ watt capacity at 208V: The 4900 VA / 4600 W rating provides ample headroom for servers, storage arrays, routers, switches, and other critical devices, helping you maintain performance during brownouts or surges.
- Flexible rack/tower deployment: Designed for data centers, server rooms, and edge installations, the Liebert GXT5 adapts to your space with a versatile form factor that fits both rack mounts and free-standing setups.
- Energy Star certified: Engineered for energy efficiency, reducing operating costs and supporting sustainability goals without compromising protection.
- Built-in management and scalable runtime options: Includes management interfaces for monitoring and control, with options for expandable runtime via external battery modules to match growing protection needs.
Technical Details of Vertiv Liebert GXT5 UPS
- Power rating: 4900 VA / 4600 W
- Input voltage: 208 V
- Output voltage: 208 V
- Topology: Online double-conversion
- Form factor: Rack/Tower
- Energy Star certified
How to Install Vertiv Liebert GXT5 UPS
- Choose the installation location: Select a cool, well-ventilated area with adequate clearance for airflow and maintenance access. Ensure the space can support the weight of the unit in both rack and floor configurations.
- Prepare the mounting: If mounting in a rack, install the appropriate rails and hardware according to the rack manufacturer’s instructions. For floor-standing use, position the unit on a stable surface with vibration-free support.
- Connect the input power: Route the 208V input from the building electrical system to the UPS input, using the correct circuit protection and wiring per local electrical codes. Ensure the input cable length is minimized to reduce losses and that the outlet or distribution panel can handle the load.
- Connect protected equipment: Plug servers, networking gear, storage devices, and other critical loads into the UPS output receptacles. Maintain a balanced load across outlets to optimize performance and runtime margins.
- Configure management and monitoring: Attach any required network management options or control panels. Set up notifications, automatic self-tests, and runtime expectations. Verify that the UPS communicates with your monitoring system and that alerts are routed to IT staff.
- Power on and test: Turn on the unit and run a self-test to verify proper operation. Check for any fault indicators and confirm that the UPS maintains output during simulated and real outages. Document the test results for compliance and audits.
Frequently asked questions
- Q: What loads should I protect with the Liebert GXT5? A: Protect mission-critical servers, storage arrays, network devices, and essential edge equipment. The 4900 VA / 4600 W rating at 208V provides ample capacity for typical mid‑sized data center racks and essential network infrastructure.
- Q: Is the Liebert GXT5 Energy Star certified? A: Yes. It is designed to meet Energy Star standards for energy efficiency, helping reduce operating costs while delivering reliable power protection.
- Q: Can runtime be expanded? A: Runtime can be extended with external battery modules or scalable battery options, enabling you to tailor protection to your workload and uptime requirements.
- Q: How do I monitor and manage the UPS? A: The Liebert GXT5 includes built-in management interfaces and supports remote monitoring. You can receive alerts, monitor power quality data, and perform configuration tasks through supported network or local interfaces.
- Q: Is 208V input/output standard for this model? A: Yes. The GXT5 is designed for 208V environments, which is common in data centers, telecommunications rooms, and office infrastructure using higher voltage utility feeds.
- Q: How should I install it in a small office or edge location? A: Use the compact rack/tower form factor to fit into tight spaces. Ensure adequate ventilation, secure mounting, and a clear path for service access. Connect loads to optimized outlets and keep cabling tidy to minimize interference.