Vertiv Liebert MicroPOD - (8) NEMA 5-20R| 16A| UPS Maintenance Bypass/Switch

LiebertSKU: 5467430

Price:
Sale price$408.40

Description

Vertiv Liebert MicroPOD - (8) NEMA 5-20R | 16A | UPS Maintenance Bypass/Switch

The Vertiv Liebert MicroPOD offers a compact, reliable solution for critical power management in data centers, server rooms, and facilities that rely on an Uninterruptible Power Supply (UPS). This maintenance bypass switch provides a dedicated path to move load power between the UPS output and a bypass route, enabling maintenance, testing, or replacement of the UPS without interrupting essential equipment. With eight NEMA 5-20R outlets and a 16-amp rating, MicroPOD is designed to simplify routine service, minimize downtime, and protect sensitive electronics that demand steady, uninterrupted power.

  • Seamless UPS maintenance: The MicroPOD enables a safe, controlled bypass of the UPS, allowing maintenance or replacement without taking connected critical equipment offline.
  • Reliable outlet configuration: Comes with (8) NEMA 5-20R receptacles to accommodate a wide range of IT and equipment needs in rack, cabinet, or room environments.
  • Power protection with predictable performance: The unit’s 16A rating supports typical enterprise loads while maintaining stable, conditioned power for connected devices during maintenance windows.
  • Compact, purpose-built design: Engineered to fit into spaces where efficient power management is essential, delivering a durable solution that complements compatible Liebert UPS architectures.
  • Ease of integration and serviceability: Designed for straightforward installation, clear load transfer operations, and minimal disruption to ongoing operations during maintenance events.

Technical Details of Vertiv Liebert MicroPOD

  • Product family: Vertiv Liebert MicroPOD
  • Outlet configuration: (8) NEMA 5-20R receptacles
  • Current rating: 16 A
  • Bypass function: UPS maintenance bypass/switch to isolate the UPS during maintenance
  • Application: Suited for data centers, server rooms, and facilities that require uninterrupted operation during UPS servicing
  • Voltage context: Designed for standard 120 V systems typical of NEMA 5-20R outlets
  • Compatibility: Works with Liebert UPS architectures to simplify maintenance workflows
  • Protection: Provides a dedicated bypass path to reduce downtime risks during UPS maintenance activities

How to install Vertiv Liebert MicroPOD

  • Plan the installation location: Choose a suitable rack or cabinet area with adequate clearance around the MicroPOD for safe access and proper cable routing.
  • Shut down non-critical loads if required: While the MicroPOD enables bypass maintenance, ensure a controlled environment by communicating maintenance windows to stakeholders and, when necessary, temporarily safeguarding sensitive equipment.
  • Mount and secure: Install the MicroPOD in the designated space using standard mounting methods appropriate for your rack or enclosure, following Liebert installation guidelines.
  • Connect the UPS and loads: Attach the UPS input/output to the MicroPOD as specified in the user manual, and connect critical loads to the (8) NEMA 5-20R outlets. Ensure all connections are secure and correctly routed to minimize interference.
  • Configure bypass operation: Set up the maintenance bypass path according to the product’s operating procedure, ensuring a clear transfer path between UPS output and bypass routes to support maintenance without interrupting critical services.
  • Test the transfer: With the system powered, perform a controlled transfer test to verify that loads can be switched between UPS and bypass without fault, and confirm that indicators reflect the bypass state accurately.

Frequently asked questions

  • Q: What is the primary purpose of the Vertiv Liebert MicroPOD?
  • A: The MicroPOD provides a dedicated maintenance bypass switch for UPS systems, enabling maintenance, testing, and replacement of the UPS without interrupting critical loads. It helps ensure high availability by maintaining a safe transfer path for power during service events.
  • Q: How many outlets does the MicroPOD include and what type are they?
  • A: It includes (8) NEMA 5-20R receptacles, designed for standard 120 V applications and compatible with a range of IT equipment and peripherals typically deployed in data centers and server rooms.
  • Q: What is the maximum load current the MicroPOD supports?
  • A: The device is rated for 16 A, allowing you to support a balance of equipment loads while maintaining a reliable bypass pathway during maintenance windows.
  • Q: Can the MicroPOD be used with any UPS, or is it specific to Vertiv Liebert systems?
  • A: The MicroPOD is designed to integrate with Liebert UPS architectures, ensuring compatibility and streamlined maintenance workflows within Vertiv's power protection ecosystem.
  • Q: Is professional installation required?
  • A: Installation and configuration should follow the manufacturer’s guidelines and may benefit from a qualified technician, especially to ensure proper wiring, transfer operation, and safety compliance in data centers or critical facilities.