Description
Vertiv Liebert MicroPOD MP2-220K Bypass Switch
Discover reliable power distribution with the Vertiv Liebert MicroPOD MP2-220K Bypass Switch, a compact, robust solution designed for data centers, server rooms, and edge deployments. This bypass switch enables maintenance without powering down critical equipment, preserving uptime and ensuring operational continuity. With dedicated IEC connections and a concise 230 V AC, 2000 VA capacity, it’s engineered to complement Liebert Uninterruptible Power Supplies and MicroPOD configurations, delivering a seamless path for service while keeping loads protected and synchronized.
- Versatile outlet configuration: 1 x IEC 60320 C19, 1 x IEC 60320 C14, and 8 x IEC 60320 C13 outlets, offering flexible attachment for servers, networking gear, and peripherals in compact spaces.
- Power capacity for small to mid-sized deployments: 2000 VA rating supports critical equipment during maintenance windows, enabling uninterrupted operations and faster servicing without interruption to essential loads.
- Efficient 230 V AC performance: Optimized for standard European and many international data center environments, aligning with common rack power architectures and minimizing energy waste.
- Compact, modular integration: Designed to fit alongside Liebert MicroPOD assemblies, providing a streamlined, scalable solution that grows with your infrastructure while maintaining easy access for technicians.
- Easy installation and maintenance workflow: Intuitive wiring and straightforward bypass operation reduce complexity during routine maintenance, prolong equipment life, and simplify disaster recovery planning.
Technical Details of Vertiv Liebert MicroPOD MP2-220K Bypass Switch
- Product: Vertiv Liebert MicroPOD MP2-220K Bypass Switch
- Outlets: 1 x IEC 60320 C19, 1 x IEC 60320 C14, 8 x IEC 60320 C13
- Electrical rating: 2000 VA
- Nominal input voltage: 230 V AC
- Recommended environment: Standard data center and edge deployments
- Application: Bypass switch for maintenance without interrupting critical loads
- Compatibility: Designed to integrate with Vertiv Liebert MicroPOD systems and compatible UPS configurations
how to install Vertiv Liebert MicroPOD MP2-220K Bypass Switch
Installing the MP2-220K bypass switch is a straightforward process meant to minimize downtime and maintain electrical safety. Follow these general steps to ensure a proper setup in a compliant data center or office environment:
- Power Down and Prepare: Ensure all connected equipment is properly shut down following your standard operating procedures. Confirm the availability of appropriate personal protective equipment (PPE) and verify the electrical panel is de-energized before handling any connections.
- Mount and Position: Place the MP2-220K in a suitable rack or cabinet space with adequate ventilation. Ensure there is clearance for cable routing and service access to both input and output ports.
- Connect Input Power: Attach the 230 V AC input supply to the specified input connector on the bypass switch (C14 or the designated power input port). Use a properly rated power cord and ensure secure, strain-relief connections to prevent accidental disconnections.
- Wire Outputs to Loads: Connect critical devices to the 1 x IEC 60320 C19, 8 x IEC 60320 C13 outlets as required. Distribute loads according to your organization’s power planning and ensure individual cable ratings match the connected equipment.
- Configure Bypass Operation: Set the bypass switch mode per the user manual, enabling maintenance bypass while preserving load protection. Verify that the bypass path is correctly engaged before initiating any maintenance tasks.
- Test and Validate: Slowly re-energize the system and verify that all connected devices power on correctly. Check indicators or alarms if present, and confirm the bypass path is functioning as intended without unintended interruptions.
- Document and Monitor: Record the installation details, including inlet/outlet assignments and any configuration steps. Implement ongoing monitoring to detect faults early and ensure ongoing reliability of the bypass function.
Frequently asked questions
- What is the Vertiv Liebert MicroPOD MP2-220K Bypass Switch used for? It serves as a maintenance bypass solution, allowing service on a connected UPS or power subsystem without interrupting the load, improving uptime and simplifying maintenance workflows.
- What outlets does it include? The unit provides 1 x IEC 60320 C19, 1 x IEC 60320 C14, and 8 x IEC 60320 C13 receptacles to support a range of servers, networking gear, and peripherals.
- What is the electrical rating? The bypass switch is rated for 2000 VA at 230 V AC, suitable for compact to mid-sized deployments where a reliable bypass path is essential during maintenance windows.
- How does bypass operation benefit data centers? By allowing technicians to service the UPS or power path without taking connected equipment offline, bypass operation minimizes downtime and protects critical workloads during maintenance and testing.
- Is this compatible with other Liebert systems? It is designed to integrate with Vertiv Liebert MicroPOD configurations and related UPS setups, enabling cohesive power management across the deployment.
- What installation considerations should I keep in mind? Ensure proper electrical wiring, adequate ventilation, cable management, and adherence to local electrical codes. Follow the manufacturer’s installation guide for bypass settings and safety procedures.