Description
Vertiv Liebert POD PD2 - (2) NEMA L14-30R | UPS Maintenance Bypass
The Vertiv Liebert POD PD2 is a purpose-built power output distribution unit engineered to simplify maintenance and maximize uptime for critical IT and electrical systems. Designed to work in harmony with Liebert UPS families, particularly the GXT4 8-10kVA models, the POD PD2 provides a reliable, code-compliant bypass path and clean power distribution to essential loads. This compact, purpose-driven device helps data centers, server rooms, network closets, and edge installations manage heavy loads with confidence, even when the primary UPS is undergoing service or replacement. By delivering a dedicated bypass route and targeted outlet configuration, the POD PD2 minimizes downtime, reduces risk during maintenance windows, and supports efficient load management in demanding environments.
- Seamless UPS maintenance bypass capability with a dedicated bypass path that isolates the UPS from the critical load during service. This means technicians can perform preventive maintenance, battery swaps, or firmware updates without interrupting power to essential equipment, preserving uptime and safeguarding sensitive devices.
- Two NEMA L14-30R outlets provide flexible, code-compliant power distribution for critical loads. The dual outlets accommodate 120/208-240V configurations commonly used in data centers and network rooms, enabling you to allocate circuits efficiently and simplify cabling during routine maintenance or expansion.
- Optimized compatibility with Liebert GXT4 8-10kVA UPS systems, delivering a tuned interface between the UPS and the facility load. This integration helps ensure stable power delivery, coordinated protection, and predictable transfer behavior as loads scale or as your infrastructure evolves.
- Robust design built for reliability in demanding environments. The POD PD2 concentrates essential power management features into a compact enclosure that supports orderly maintenance operations, clear load prioritization, and straightforward wiring. It is suitable for server rooms, data hall spaces, telecom closets, and other mission-critical settings where uptime matters.
- Clear indicators, straightforward wiring, and service-friendly architecture help technicians install, configure, and service the POD PD2 with confidence. By reducing complexity and facilitating quick maintenance cycles, the unit supports efficient facility operations and improves overall IT resilience.
Technical Details of Vertiv Liebert POD PD2
- Specifications available on ec.synnex.com; refer to the product's UPC or SKU for exact values and configuration details.
How to install Vertiv Liebert POD PD2
- Plan the installation in a clean, ventilated area near the supported Liebert GXT4 UPS. Ensure there is adequate clearance for airflow, service access, and cable management, and verify that the mounting surface or rack space meets the unit’s physical requirements.
- Power down or isolate the UPS maintenance path following your facility’s safety procedures and local electrical codes. Confirm that the intended bypass path will carry the load during maintenance and that all personnel are briefed on the procedure.
- Mount the POD PD2 in the selected location and connect the system to the appropriate distribution circuits. Route and label cabling clearly, connecting the two NEMA L14-30R outlets to the designated critical loads so that they can be served by the bypass path when the UPS is offline for maintenance.
- Wire the maintenance bypass according to the manufacturer’s guidelines and local electrical codes. Ensure proper grounding, secure connections, and strain relief for all cables. Double-check all connections before applying power.
- Power up the system and validate the bypass function. Verify that the loads receive uninterrupted power when the UPS is in bypass mode, and that the indicator lights or status signals reflect normal operation. Document the configuration and conduct a supervised test to confirm performance under typical load conditions.
Frequently asked questions
-
Q: What is the Vertiv Liebert POD PD2 used for?
A: The POD PD2 provides a dedicated UPS maintenance bypass and output distribution, allowing maintenance work on the UPS without interrupting critical loads. It helps maintain uptime in data centers, server rooms, and network closets by isolating the UPS during service while still powering essential equipment through the bypass path. -
Q: How many outlets does it have and what outlets are they?
A: The unit features two NEMA L14-30R receptacles, designed for 120/208-240V configurations commonly used in enterprise environments. These outlets enable flexible distribution of critical loads while enabling a safe bypass during UPS maintenance. -
Q: Is the POD PD2 compatible with Liebert GXT4 8-10kVA UPS systems?
A: Yes, the POD PD2 is engineered to meet the demands and integration needs of Liebert GXT4 8-10kVA UPS systems, providing a seamless interface for bypass operations and load distribution within those configurations. -
Q: Where can I find the exact technical specifications?
A: Exact specifications, including UPC and SKU details, are listed on the official ec.synnex product page. Refer to the product’s specifications section on ec.synnex.com for precise numbers and configuration data. -
Q: How does the maintenance bypass improve uptime?
A: By isolating the UPS from the load during maintenance, technicians can perform battery replacements, firmware updates, or routine service without interrupting critical equipment. This reduces planned downtime and enhances the resilience of IT and electrical infrastructure.
Customer reviews
Showing - Of Reviews