Vertiv Liebert POD PD2 - (4) NEMA 5-20R| (2) L6-30R| (2) L6-20R| UPS Maintenance

LiebertSKU: 5467499

Price:
Sale price$593.49

Description

Vertiv Liebert POD PD2: UPS Maintenance Bypass Power Distribution for GXT4 8-10kVA

The Vertiv Liebert POD PD2-104 is a purpose-built power output distribution (POD) unit that integrates a built-in maintenance bypass to streamline UPS service. Designed to work in harmony with the Liebert GXT4 8-10kVA UPS family, this POD delivers reliable, organized distribution of essential loads while enabling maintenance or replacement of the UPS without interrupting power to connected equipment. Built for data centers, server rooms, and industrial environments, the POD PD2 ensures uptime protection, reduces downtime, and simplifies ongoing management of critical power systems.

  • Outlet configuration tailored for diverse equipment: (4) NEMA 5-20R, (2) L6-30R, and (2) L6-20R provide flexible, readily available receptacles for servers, networking gear, and other critical devices.
  • Built-in maintenance bypass for uninterrupted service: when maintenance or replacement is required on the UPS, the POD PD2 allows technicians to service the UPS without interrupting power to connected loads, preserving uptime for critical operations.
  • Seamless integration with GXT4 8-10kVA UPS models: specifically engineered to complement the Liebert GXT4 line, ensuring compatibility, streamlined installation, and dependable coordination between the UPS and the POD.
  • Compact, scalable design for data centers and server rooms: engineered to fit within standard rack or cabinet configurations and to adapt to growing load demands, helping facilities optimize space and power distribution.
  • Durable, reliable construction with safety in mind: built to meet stringent industry standards, offering robust performance under demanding environments while maintaining clear labeling and safe operation for staff and technicians.

Technical Details of Vertiv Liebert POD PD2

  • Outlet configuration: 4 x NEMA 5-20R, 2 x L6-30R, 2 x L6-20R
  • Maintenance bypass: integrated feature for UPS service without power interruption
  • Compatibility: designed for use with Vertiv Liebert GXT4 8-10kVA UPS models
  • Purpose: power output distribution unit (POD) to safeguard critical loads during UPS maintenance
  • Construction: durable POD module intended for data centers, server rooms, and industrial environments

How to Install Vertiv Liebert POD PD2

  • Plan the installation by confirming the POD PD2 outlet configuration matches your load requirements and that it is compatible with your GXT4 8-10kVA UPS system.
  • Power down for initial safety if required by your facility’s maintenance procedures, then verify that the UPS is prepared for maintenance access with the ability to engage the bypass function.
  • Position the POD PD2 in a suitable location near the UPS and within reach of the loads it will serve. Ensure adequate space for ventilation and cable management to maintain airflow and organization.
  • Connect the POD PD2’s input wiring to the corresponding UPS output circuits, and route each load to the appropriate outlets (NEMA 5-20R, L6-30R, L6-20R) according to your load plan and labeling standards.
  • Engage the built-in maintenance bypass when performing UPS service or replacement, following the manufacturer’s safety procedures to transfer power from the UPS to the bypass path as required.
  • Test the configuration by energizing the loads and verifying that power flows normally through the POD PD2 during standard operation and that the maintenance bypass permits safe UPS maintenance without impacting connected equipment.

Frequently asked questions

  • What is the Vertiv Liebert POD PD2? It is a power output distribution unit with an integrated maintenance bypass designed to work with Liebert GXT4 UPS systems, enabling service without interrupting critical loads.
  • What outlets are included on the POD PD2? The unit provides a combination of (4) NEMA 5-20R, (2) L6-30R, and (2) L6-20R outlets to accommodate a range of devices and power requirements.
  • Why is a maintenance bypass important? The maintenance bypass lets technicians service or replace the UPS without shutting down connected equipment, which minimizes downtime in data centers and other mission-critical environments.
  • Is the POD PD2 compatible with GXT4 8-10kVA UPS models? Yes, it is specifically designed to integrate with the Liebert GXT4 series to optimize power distribution and uptime.
  • Where should the POD PD2 be installed? It should be placed close to the UPS and the loads it serves, within a suitable rack or cabinet environment, with attention to ventilation and cable management for reliability and safety.