Description
Vertiv Liebert POD PD2 with UPS Maintenance Bypass
The Vertiv Liebert POD PD2 is a purpose-built Power Output Distribution (POD) unit with an integrated maintenance bypass, crafted to streamline UPS maintenance without interrupting critical loads. Designed specifically for the GXT4 8-10kVA UPS family, this POD consolidates power distribution, protection, and serviceability into a compact, reliable module. It helps data centers, server rooms, telecom closets, and edge deployments keep workloads online while technicians perform essential UPS upkeep, calibration, or replacement activities. With the Liebert POD PD2, you gain an organized, safe, and code-compliant solution for managing power delivery to critical equipment while preserving uptime during maintenance windows.
- Comprehensive outlet configuration for diverse loads: The system features a robust mix of six NEMA L6-30R outlets plus two NEMA L6-20R outlets, giving you flexible, high-quality connections for a wide range of devices and equipment. This setup supports critical servers, networking gear, storage arrays, and other essential infrastructure in a single, neatly arranged POD panel.
- Built-in UPS maintenance bypass: The standout feature of the POD PD2 is its maintenance bypass capability. When you need to service or replace the UPS, you can route power around the unit without disconnecting or powering down connected equipment. This enables safe, controlled maintenance and reduces the risk of downtime for your facility during service events.
- Designed for GXT4 8–10 kVA UPS compatibility: Specifically engineered to accompany Vertiv’s GXT4 line, the POD PD2 ensures seamless integration with the UPS architecture you rely on for critical uptime. The result is a cohesive system where distribution, monitoring, and bypass functionality work in concert to support continuous operation.
- Rugged, serviceable enclosure for reliability: Built with a sturdy chassis, the POD PD2 emphasizes durability, easy access, and clear labeling. Its design prioritizes safe maintenance procedures, straightforward cable routing, and predictable performance in demanding environments such as data centers, enterprise IT rooms, or remote office sites.
- Efficient integration and management: The POD PD2 is crafted for straightforward installation and tidy cable management. Its compact footprint helps conserve valuable rack or cabinet space while delivering centralized power distribution, making it easier to monitor, test, and maintain your power infrastructure over time.
Technical Details of Vertiv Liebert POD PD2
- Outlet configuration: (6) NEMA L6-30R and (2) NEMA L6-20R outlets for versatile load connections
- Maintenance bypass: Integrated UPS maintenance bypass for uninterrupted service during UPS maintenance or replacements
- Compatibility: Engineered for use with Vertiv GXT4 8–10kVA UPS models
- Enclosure: Durable steel construction with proper labeling and accessible service points
- Protection and safety: Built to meet standard electrical safety requirements for distribution equipment, enabling safe operation during installation and servicing
How to install Vertiv Liebert POD PD2
Installing the Vertiv Liebert POD PD2 involves careful planning, adherence to electrical codes, and following the manufacturer’s installation manual. Start by selecting a suitable location with adequate ventilation, clearance for servicing, and appropriate cable routing paths. Ensure the UPS and POD PD2 are installed in accordance with local electrical codes and facility guidelines, with appropriate clearance for safe maintenance access.
Step-by-step guidance (general best practices):
- Power down and lockout the UPS and any adjacent equipment prior to disconnecting power for installation checks.
- Mount or place the POD PD2 in close physical proximity to the GXT4 UPS to minimize cable runs and simplify management of the six L6-30R outlets and two L6-20R outlets.
- Connect the POD PD2 inputs and outputs per the manufacturer’s wiring diagrams. Ensure that the L6-30R and L6-20R outlets are wired to the intended protected loads, maintaining separation between critical IT gear and any non-critical devices if desired.
- Integrate the built-in maintenance bypass control as directed by the manual. This enables you to perform UPS service without powering down connected loads, preserving uptime for essential equipment during maintenance windows.
- Label each outlet clearly, map loads to specific outlets, and verify polarity and grounding. Confirm that cable management is tidy to reduce strain, improve airflow, and ease future servicing.
- Power up gradually and test the maintenance bypass function. Validate that loads continue to receive power when the UPS is isolated for maintenance, and that normal operation resumes after bypass re-engagement.
- Document the configuration, including outlet assignments, bypass procedures, and maintenance schedules. Maintain an up-to-date inventory of connected devices to streamline future service and expansion.
Safety tip: Always follow the product’s official installation manual and local electrical codes. If you’re unsure about wiring or bypass operations, consult a licensed professional electrician or a Vertiv support representative. Properly securing and labeling all connections minimizes risks and helps technicians perform maintenance efficiently with minimal downtime.
Frequently asked questions
- What is the Vertiv Liebert POD PD2? The POD PD2 is a power output distribution module with a built-in maintenance bypass designed to work with Vertiv’s GXT4 8–10 kVA UPS models. It distributes power to outlets and enables maintenance activities without interrupting power to connected loads.
- Why is the maintenance bypass important? The maintenance bypass allows technicians to service or replace the UPS while the loads remain powered. This capability is essential for maintaining uptime in data centers, server rooms, and other mission-critical environments where unplanned downtime is costly.
- What outlets are included? The POD PD2 provides six NEMA L6-30R outlets and two NEMA L6-20R outlets, offering a mix of high-current and versatile connections for diverse equipment and loads.
- Is the POD PD2 compatible with all UPS brands? The POD PD2 is designed for use with Vertiv GXT4 8–10kVA UPS models. For other UPS platforms, consult Vertiv documentation to confirm compatibility and safe integration before installation.
- How does it help with cable management? By consolidating outlets into a single POD unit near the UPS, the PD2 reduces cable clutter, simplifies routing, and makes it easier to organize and label power connections for quick maintenance and upgrades.
- Where can I find more detailed installation guidance? Refer to the official Vertiv installation manual for the POD PD2 and the GXT4 UPS. If you need additional support, contact Vertiv or your authorized distributor for guidance tailored to your facility.
Customer reviews
Showing - Of Reviews