Description
Vertiv Liebert POD PD5 - UPS Maintenance Bypass for GXT5 (PD5-002)
The Vertiv Liebert POD PD5 is a purpose-built power output distribution unit designed to optimize the performance and reliability of your GXT5 UPS system. Featuring a built-in maintenance bypass, this POD provides a safe, seamless path for UPS servicing without interrupting critical loads. Engineered for 5-10 kVA GXT5 configurations, the PD5-002 delivers versatile outlet options and rugged construction to support demanding data center, office, and industrial environments. With the Liebert POD PD5, you gain enhanced uptime, flexible power distribution, and simplified maintenance workflows—so you can focus on your business while your power infrastructure stays rock-solid.
- Integrated maintenance bypass for uninterrupted service: The PD5 includes a dedicated bypass path that lets technicians perform UPS maintenance or replacement without shedding power to critical equipment, helping to minimize downtime and protect sensitive loads.
- Flexible outlet configuration for diverse loads: It provides (2) NEMA L6-20R outlets for 250V, high-current equipment and (2) NEMA 5-15/20R outlets for standard 120/125V devices, giving you versatile distribution in a single compact unit.
- Designed to complement GXT5 UPS systems: Specifically engineered for GXT5 5-10 kVA models, the POD PD5 ensures clean power distribution, efficient bypass operation, and seamless integration with Vertiv’s data center power ecosystem.
- Rugged, space-efficient footprint: Built to fit tight data center racks or equipment closets, the PD5 combines durable construction with a compact footprint, enabling easy installation in limited spaces without sacrificing performance.
- Enhanced safety and serviceability: Labeled connections, clear bypass indicators, and straightforward wiring paths help technicians install and service the unit safely, reducing the risk of wiring errors and downtime during maintenance.
Technical Details of Vertiv Liebert POD PD5
- Model: PD5-002
- Purpose: UPS maintenance bypass and power distribution for GXT5 UPS systems
- Outlet configuration: (2) NEMA L6-20R and (2) NEMA 5-15/20R
- Compatibility: Intended for GXT5 5-10 kVA UPS models
- Product family: Liebert POD series
- Key benefit: Enables safe, rapid maintenance or UPS replacement with no disruption to critical loads
How to install Vertiv Liebert POD PD5
- Step 1 — Verify compatibility: Confirm that your GXT5 UPS is within the 5-10 kVA range and that the PD5-002 model is the correct maintenance bypass unit for your configuration.
- Step 2 — Plan placement: Choose a location that allows easy access to the PD5’s connections, maintains adequate clearance for ventilation, and accommodates both the L6-20R and 5-15/20R outlets without crowding cables.
- Step 3 — Power down and isolate: Follow your organization’s safety procedures to safely power down the UPS and isolate the circuit before beginning installation. Ensure the maintenance bypass path is clearly labeled and accessible.
- Step 4 — Make wiring connections: Connect the PD5 to the UPS output according to the installation diagram in the manual. Route and connect the (2) L6-20R outlets for high-current loads and the (2) 5-15/20R outlets for standard loads, ensuring secure, strain-relieved terminations.
- Step 5 — Verify bypass and test: Once wired, engage the built-in maintenance bypass following the manufacturer’s procedure, and conduct a controlled load test to verify power is preserved to critical equipment during maintenance.
- Step 6 — Label and document: Clearly label all outlets and provide a simple map for operators and technicians, including bypass activation steps and safety notes for quick reference during future maintenance.
Frequently asked questions
-
Q: What is the purpose of the Vertiv Liebert POD PD5?
A: The PD5 provides a built-in maintenance bypass and power distribution for GXT5 UPS systems, allowing safe UPS maintenance without interrupting critical loads. It is designed to streamline service workflows and improve uptime.
-
Q: How many outlets does the PD5 offer and of what types?
A: The unit features two NEMA L6-20R outlets (250V, high current) and two NEMA 5-15/20R outlets (125V), offering flexible distribution for mixed equipment in a single enclosure.
-
Q: Is the PD5 compatible with all GXT5 configurations?
A: The PD5-002 is intended for GXT5 UPS systems in the 5-10 kVA range. Always verify compatibility with your specific UPS model and review the latest product documentation from Vertiv.
-
Q: Can the maintenance bypass be tested without affecting loads?
A: Yes. The integrated bypass is designed to allow controlled maintenance activities. Conduct tests per the manual to ensure bypass operation preserves power to critical equipment while maintenance is performed on the UPS.
-
Q: What environments is the PDP PD5 suitable for?
A: The PD5 is intended for data centers, server rooms, and commercial facilities where reliable power distribution and scheduled maintenance are essential. Its rugged design and flexible outlet configuration make it suitable for a range of installations.