Vertiv Liebert POD PD5 - (2) NEMA L6-30R| (4) NEMA 5-15/20R| UPS Maintenance Bypass for GXT5 (PD5-003)

LiebertSKU: 5630375

Price:
Sale price$639.25

Description

Vertiv Liebert POD PD5 - (2) NEMA L6-30R | (4) NEMA 5-15/20R | UPS Maintenance Bypass for GXT5 (PD5-003)

The Vertiv Liebert POD PD5-003 is the high-performance power distribution solution designed to work in perfect harmony with Liebert GXT5 UPS systems. Engineered for reliability, scalability, and seamless uptime, this POD unit provides a smart, consolidated power distribution channel that protects critical equipment while simplifying installation and maintenance. Whether you’re outfitting a data center, research lab, healthcare facility, or industrial workflow, the PD5-003 is built to deliver clean, resilient power to a diverse array of devices with minimal footprint and maximum ease of use.

With a focus on continuity and efficiency, the PD5-003 integrates a built-in maintenance bypass, allowing you to perform service and maintenance without interrupting the load. This capability is crucial for environments that require sustained operation and minimal downtime. The maintenance bypass is designed to route power around the UPS during service events, guaranteeing that essential systems stay powered while technicians perform diagnostics, component replacements, or firmware updates. The result is a robust, mission-critical solution that reduces risk, extends equipment life, and enhances overall operational resilience.

Designed to meet the needs of modern deployments, the POD PD5-003 features a flexible outlet configuration that includes two NEMA L6-30R receptacles and four NEMA 5-15/20R outlets. This mix of outlets supports a wide range of loads—from high-amperage servers and network gear to general-purpose electronics and peripherals. The configuration allows you to centralize power distribution directly at the point of use, minimize cable clutter, and optimize airflow for cooling efficiency. The PD5-003 is built to withstand the demands of busy data centers and enterprise environments, delivering dependable performance in challenging conditions.

Durability and thoughtful engineering underpin every aspect of the PD5-003. The enclosure is rugged, with clean, scalable integration into existing Liebert GXT5 UPS ecosystems. The unit is designed for installation in compatible racks or dedicated chassis spaces, enabling rapid deployment with minimal disruption to ongoing operations. Maintenance access is straightforward, enabling technicians to inspect, test, and service the distribution board with minimal downtime. For organizations prioritizing uptime, fault isolation, and predictable power availability, the PD5-003 stands out as a trusted, future-ready solution.

Beyond hardware, Vertiv's Liebert POD PD5-003 emphasizes intelligent power management. When paired with a GXT5 UPS, it supports coordinated protection strategies, coordinated battery management, and advanced monitoring that helps facility teams anticipate and respond to power events. The result is a more resilient IT infrastructure, with clearer visibility into power quality, load distribution, and potential issues before they impact critical workloads. This proactive approach reduces the risk of data loss, equipment damage, and unexpected downtime, delivering a strong return on investment through improved reliability and operational efficiency.

  • Seamless UPS integration: Specifically designed to work with GXT5 5-10kVA UPS models for streamlined power protection and simplified management.
  • Built-in maintenance bypass: Ensures continuous uptime during service events by routing power around the UPS for uninterrupted loads.
  • Flexible outlet configuration: (2) NEMA L6-30R and (4) NEMA 5-15/20R provide versatile power distribution for mixed loads.
  • Durable, space-efficient design: Rugged enclosure ready for rack-mount or dedicated space in data centers and enterprise environments.
  • Enhanced power management: Optimized coordination with the GXT5 UPS for improved monitoring, maintenance, and protection of critical systems.

Technical Details of PD5-003

  • Model / SKU: PD5-003 (Vertiv Liebert POD PD5)
  • Outlet configuration: 2 x NEMA L6-30R, 4 x NEMA 5-15/20R
  • Designed for compatibility with: Liebert GXT5 UPS series (5-10 kVA) for seamless integration
  • Maintenance bypass: Built-in bypass to maintain loads during UPS maintenance or service events
  • Purpose: Power output distribution unit (POD) intended to complement GXT5 UPS by centralizing distribution to connected equipment
  • Housing: Robust enclosure suitable for rack-mount or dedicated mounting within compatible environments
  • Target environments: Data centers, server rooms, IT closets, healthcare, and enterprise facilities requiring reliable, flexible power distribution

How to install Vertiv Liebert POD PD5-003

Installing the Vertiv Liebert POD PD5-003 is straightforward when paired with a GXT5 UPS system. Follow these general steps to ensure proper integration and optimal performance. Note that specific mounting and cabling practices should align with your facility’s standards and the GXT5 installation guide.

  1. Prepare the installation site: Choose a stable, well-ventilated rack or mounting area with adequate clearance for access to outlets and the maintenance bypass section. Ensure the area complies with electrical safety and local codes.
  2. Power down and secure the UPS: If currently powered, safely shut down the GXT5 UPS and disconnect it from the mains to prevent accidental energization during POD installation. Lockout/tagout procedures should be followed as required.
  3. Mount the POD PD5-003: Install the POD in a rack or designated enclosure, aligning mounting holes with rails or brackets. Use the appropriate hardware to ensure a secure fit per your facility’s standards.
  4. Connect to the UPS and load: Link the PD5-003 to the GXT5 UPS as directed by the product and UPS manuals. Connect the loads to the two NEMA L6-30R receptacles for higher-amperage devices and to the four NEMA 5-15/20R receptacles for general-purpose equipment. Organize cables to maintain airflow and avoid congestion.
  5. Verify bypass operation and power flow: After wiring, reapply power to the UPS and PD5-003. Confirm that the maintenance bypass is functional by simulating a UPS service event or following the testing procedure in the installation guide. Ensure loads continue to receive power when the bypass is engaged.
  6. Configure monitoring and labeling: Label outlets clearly for critical and non-critical loads. If the POD supports monitoring interfaces, configure any available remote management features to integrate with your facility’s monitoring systems.
  7. Test and document: Perform a full test of normal power flow, UPS battery operation, and bypass functionality. Document the test results, outlet mappings, and any load-specific considerations for future maintenance.

Frequently asked questions

  • What loads can be connected to the PD5-003? The PD5-003 supports a mix of high- and standard-load devices using (2) NEMA L6-30R outlets for higher-current equipment and (4) NEMA 5-15/20R outlets for general IT gear, peripherals, and related infrastructure. This configuration enables centralized, flexible distribution for a variety of critical loads.
  • Is the maintenance bypass included in the PD5-003? Yes. The PD5-003 includes a built-in maintenance bypass to maintain power to connected loads during UPS service or maintenance events, helping to minimize downtime.
  • Which UPS models is the PD5-003 designed to work with? The POD is designed for seamless integration with Liebert GXT5 UPS models in the 5-10 kVA range, aligning power distribution with the UPS’s protection and monitoring capabilities.
  • Can the PD5-003 be rack-mounted? Yes. The enclosure is designed for rack-mount or dedicated mounting within compatible facilities, enabling neat, scalable deployment in data centers or IT closets.
  • What are the main benefits of using the PD5-003 with a GXT5 UPS? The combination provides unified protection, maintenance bypass to minimize downtime, flexible outlet configuration for diverse loads, improved power management visibility, and a compact footprint that optimizes space and cooling efficiency.

Customer reviews

(0)

0 Out of 5 Stars


5 Stars
0
4 Stars
0
3 Stars
0
2 Stars
0
1 Star
0


Showing - Of Reviews


You may also like

Recently viewed