Vertiv Liebert POD PD5 - UPS Maintenance Bypass for GXT5 (PD5-005)
The Vertiv Liebert POD PD5 is a purpose-built power output distribution (POD) device engineered to maximize the uptime and reliability of your GXT5 5-10 kVA UPS system. Designed to simplify UPS maintenance and component replacement, the PD5 lets technicians perform essential service without interrupting critical loads. This compact, rugged module integrates seamlessly into data centers, server rooms, and IT closets, delivering a dependable bypass path that protects sensitive equipment while maintenance is performed. With its durable construction and carefully arranged receptacles, the Liebert POD PD5 ensures safe, organized power distribution during routine maintenance windows and emergency readiness alike.
- Seamless UPS maintenance bypass — The PD5 enables maintenance and replacement tasks on your GXT5 UPS without powering down connected equipment, minimizing downtime and preserving critical operations.
- Dual high-capacity NEMA L6-30R and multiple NEMA 5-20R outlets — It features (2) NEMA L6-30R outlets for secure, high-current connections and (4) NEMA 5-20R outlets for flexible, safe distribution of IT loads and peripherals.
- Designed for reliability in challenging environments — Built to withstand the rigors of data centers, telecom rooms, and server closets, the POD PD5 offers robust connectors, solid mechanical design, and dependable operation when it matters most.
- Compact, modular footprint — This maintenance-friendly POD is engineered to fit neatly into existing IT infrastructures, enabling organized wiring and simple integration with your legacy power chain.
- Supports rapid, safe maintenance workflows — By providing a clear, dedicated bypass path, the PD5 accelerates service procedures, reduces human error, and helps teams maintain service-level agreements without compromising safety or power integrity.
Technical Details of Vertiv Liebert POD PD5
- Compatibility and purpose: A maintenance bypass and power distribution module designed to accompany the GXT5 UPS family, enabling service without load interruption.
- Receptacle configuration: (2) NEMA L6-30R outlets and (4) NEMA 5-20R outlets to accommodate a range of connected equipment and service tooling.
- Electrical and physical characteristics: Detailed electrical ratings, mounting options, and enclosure specs are provided by official documentation; refer to the supplier’s specifications for exact figures and compliance statements.
- Notes: This section summarizes core attributes and emphasizes the PD5’s role in uptime optimization and streamlined maintenance workflows.
how to install Vertiv Liebert POD PD5
Before installation, confirm that the GXT5 UPS is de-energized and that all appropriate safety procedures are in place in accordance with your facility’s safety protocols. The PD5 is designed to be integrated into the UPS power path to provide a dedicated, safe bypass route for maintenance tasks.
1) Plan your layout: Identify a suitable location for the POD PD5 that allows easy access to the NEMA L6-30R and NEMA 5-20R outlets, while ensuring adequate clearance for cables and airflow. Label cables and plan the routing to minimize risk of accidental disconnection during maintenance.
2) Prepare connections: Verify that the DUT (device under test) or equipment you intend to service is connected through the PD5’s bypass path. Ensure that all outlets are unoccupied or used as intended during maintenance windows. Use appropriate cable management to prevent strain or accidental unplugging.
3) Mount and secure: Secure the POD PD5 in accordance with the manufacturer’s mounting guidelines. Ensure stability and alignment with surrounding equipment to avoid impact damage or interference with other components.
4) Connect to the UPS and loads: Connect the PD5 to the GXT5 UPS per the installation instructions, ensuring the NEMA L6-30R and NEMA 5-20R outlets are wired to the intended loads and service points. Double-check all terminations for tightness and safety before energizing.
5) Validate operation: Power up the system and verify that the maintenance bypass path engages correctly. Confirm that connected loads are protected during maintenance and that the UPS remains available for rapid re-energization after service completion. Perform a controlled test to ensure all indicators, switches, and interlocks function as designed.
6) Documentation and safety: Record the installation details, including any load distributions, cable routes, and maintenance procedures. Maintain up-to-date safety and wiring diagrams for future service needs and audits.
Frequently asked questions
Q: What is the primary purpose of the Vertiv Liebert POD PD5?
A: The POD PD5 is a maintenance bypass and power distribution unit designed to enable UPS maintenance on the GXT5 series without interrupting critical loads, improving uptime and reducing planned downtime during service tasks.
Q: Which outlets are available on the PD5?
A: The unit provides (2) NEMA L6-30R outlets for high-current connections and (4) NEMA 5-20R outlets for versatile distribution to IT equipment and service tools.
Q: Is the POD PD5 compatible with other UPS models?
A: The PD5 is specifically described as a maintenance bypass for the GXT5 UPS family. For compatibility with additional models, consult Vertiv’s official documentation or a certified technician.
Q: How does the PD5 impact uptime during maintenance?
A: By offering a dedicated bypass path, the PD5 allows technicians to service the UPS without powering down connected equipment, thereby reducing planned downtime and protecting business-critical loads.
Q: What is included in the installation and safety considerations?
A: Installation requires planning for proper outlet distribution, secure mounting, and adherence to safety protocols. Always follow the manufacturer’s instructions and ensure that all connections are secure and properly labeled to prevent accidental disconnections during maintenance.