Vertiv Liebert POD PD5 - (6) IEC|UPS Maintenance Bypass for GXT5 8-10KVA HV

LiebertSKU: 6255086

Price:
Sale price$639.25

Description

Vertiv Liebert POD PD5 - UPS Maintenance Bypass for GXT5 8-10KVA HV

The Vertiv Liebert POD PD5 is a purpose-built power distribution unit designed to preserve uptime during maintenance, repair, or replacement of the Vertiv Liebert GXT5 8-10kVA High Voltage (208V) UPS systems. This robust maintenance bypass solution provides a safe, reliable path for power to critical loads while the UPS is offline or undergoing servicing. Built to withstand the rigors of data centers, telecom rooms, and industrial environments, the PD5 ensures that essential equipment remains powered without compromising personnel safety or system integrity. Its thoughtful design integrates seamlessly with the GXT5 HV lineup, delivering predictable transfer behavior, clear load segregation, and intuitive operation when every second counts. If you manage a high-availability environment that demands minimal downtime during UPS maintenance, the POD PD5 is a trusted, scalable choice that aligns with modern data center modernization and resilience strategies.

  • Maintenance bypass capability: The PD5 provides a dedicated maintenance bypass path so technicians can service the GXT5 8-10kVA HV UPS without interrupting critical loads. This design minimizes downtime risk and simplifies the service workflow, helping you meet strict service-level agreements.
  • Six IEC outlets for flexible distribution: The setup features (6) IEC-compatible outlets, delivering versatile load distribution for essential equipment while preserving organized cable management and clear power paths during maintenance events.
  • High-voltage compatibility (208V HV): Specifically engineered for 208V high-voltage deployments, the PD5 optimizes performance with Vertiv Liebert GXT5 systems, ensuring clean power transfer and reliable operation within enterprise, data center, and industrial applications.
  • Compact, rugged enclosure: Engineered for demanding environments, the PD5 combines a durable enclosure with a compact footprint that fits neatly in server rooms and closet spaces, reducing installation complexity while maintaining serviceability and heat management.
  • Safety-first design and visibility: The unit emphasizes safety with clearly labeled connections, protective interlocks, and fault detection features that guide technicians through maintenance procedures and prevent unintended energization of critical circuits.

Technical Details of Vertiv Liebert POD PD5

  • Ventilated, industrial-grade enclosure: Built to endure continuous operation in data centers and industrial environments, with accessible service panels for straightforward maintenance and inspection.
  • Load distribution configuration: Designed to support a (6) IEC receptacle arrangement to accommodate common critical-load groupings and to simplify circuit planning during UPS maintenance.
  • Voltage and by-pass topology: Optimized for 208V high-voltage UPS systems, delivering a reliable bypass path that isolates the UPS during service while keeping loads energized.
  • Safety and interlocks: Includes interlock features and clear labeling to guide safe operation and minimize the risk of accidental energization or miswiring during maintenance activities.
  • Compatibility: Specifically tailored to work with Vertiv Liebert GXT5 8-10kVA HV UPS models, enabling a cohesive maintenance strategy across your Liebert green power infrastructure.

how to install Vertiv Liebert POD PD5

Installing the Vertiv Liebert POD PD5 is a straightforward step aligned with standard data-center power maintenance practices. Before installation, confirm that you have the correct SKU for your GXT5 8-10kVA HV UPS and that the installation area complies with local electrical codes and facility standards. Here is a practical installation guide to help you prepare and execute a clean, safe setup:

  • Prepare the site: Choose a stable, well-ventilated area with adequate clearance for service access and cable management. Verify floor load capacity and ensure the space can accommodate the PD5 and its service pathways.
  • Power down and isolate: Place the GXT5 UPS into a safe maintenance state as directed by the vendor’s service manual. Isolate the UPS battery system per safety guidelines and confirm no ambient energy is accessible to the maintenance bypass path during wiring.
  • Mounting and placement: Position the PD5 in proximity to the UPS and load distribution points. Securely mount if required, ensuring compliance with any rack, stand, or wall-mount requirements specified by the manufacturer.
  • Connect the bypass and loads: Route the bypass connection from the GXT5 UPS to the PD5’s bypass input and connect the six IEC outlets to the designated critical loads. Use proper strain relief and labeling to maintain organized, safe cabling during maintenance cycles.
  • Label and verify wiring: Clearly label all connections and loads. Double-check that each IEC outlet corresponds to its intended circuit. Power up in a controlled sequence and verify that the bypass path transfers as expected when simulating maintenance scenarios.
  • Test and document: Perform a controlled transfer test to validate that the maintenance bypass path sustains critical loads without UPS input, and confirm 208V HV operation remains stable across outlets. Record test results and update maintenance records for future service events.

During installation, always follow the manufacturer’s safety guidelines and local electrical codes. The PD5 is designed to provide a reliable, service-friendly bypass option, but it requires careful handling to ensure all connections remain secure and the overload protections remain intact. If you need to scale or reconfigure load distribution in the future, the PD5’s modular approach makes it straightforward to adapt to changing data-center needs while preserving uptime.

Frequently asked questions

  • What is the Vertiv Liebert POD PD5 used for? The POD PD5 is a maintenance bypass and power distribution unit designed to keep critical loads powered while the Vertiv Liebert GXT5 8-10kVA HV UPS undergoes maintenance, service, or replacement. It provides a safe, isolated path to connect loads during UPS downtime.
  • Is the PD5 compatible with GXT5 8-10kVA HV UPS models? Yes. The PD5 is purpose-built to work with Vertiv Liebert GXT5 high-voltage UPS models in the 8-10kVA range, ensuring seamless integration with existing Liebert infrastructure.
  • How many outlets does the PD5 provide? The unit features six IEC outlets for flexible load distribution, enabling efficient management of critical equipment during maintenance windows.
  • How does the maintenance bypass work? The maintenance bypass creates a dedicated power path that allows technicians to service the UPS without interrupting powered loads. This reduces downtime risk and supports safer, faster maintenance operations.
  • What safety features should I expect? The PD5 includes clearly labeled connections, interlocks, and fault-detection indicators to guide technicians and prevent unintended energization during maintenance.
  • Where can I find exact specifications for the PD5? Technical details are provided by the vendor’s specifications and the product listing. For precise UPC/SKU-based data, refer to the supplier’s official specification sheets and listing resources.