Description
Vertiv Liebert PSI5 UPS - 1100VA Line-Interactive Rackmount with NIC
The Vertiv Liebert PSI5 1100VA UPS is purpose-built to protect critical IT equipment in small to mid-sized data centers, network closets, and office server rooms. With a robust 1100 VA / 990 W capacity, a 120 VAC input/output, and a reliable line-interactive topology, this unit delivers dependable power protection against outages, sags, surges, and harmonic disturbances. Designed for rack-mount deployment and enhanced by the included RDU120 network interface card, PSI5 makes remote management effortless, enabling proactive monitoring, graceful shutdowns, and automated alerts to keep your operations online and your data safe. Economical to operate and simple to deploy, it’s an ideal backbone for servers, switches, network gear, and other essential equipment in demanding environments.
- High-capacity protection: 1100 VA / 990 W output ensures your critical devices stay powered during outages, with clean, regulated sinewave delivery to prevent damage from brownouts and voltage spikes.
- Rack-mount friendly design: Built for standard 19-inch racks, the PSI5 integrates neatly into IT cabinets and data center racks, saving space while delivering reliable power protection where it’s needed most.
- Network-enabled management with NIC: The RDU120 network interface card is included for remote monitoring, web-based management, alerts, and graceful shutdowns across your networked devices.
- Voltage regulation and surge protection: Automatic Voltage Regulation (AVR) maintains stable output voltage to protect sensitive equipment from fluctuations, while surge suppression defends against transient spikes.
- Simple, maintenance-friendly setup: Easy installation with clear indicators and straightforward serviceability, designed to minimize downtime during deployment and routine checks.
Technical Details of Vertiv Liebert PSI5 UPS - 1100VA Line-Interactive Rackmount with NIC
- Model: Vertiv Liebert PSI5 1100VA UPS
- Topology: Line-Interactive UPS designed to balance efficiency with robust protection for sensitive loads
- Power rating: 1100 VA / 990 W
- Input voltage: 120 VAC (typical for US systems)
- Output voltage: 120 VAC ±5%, 60 Hz
- Form factor: Rack-mountable chassis compatible with standard 19-inch racks
- Management: Includes RDU120 network interface card for remote monitoring, alerts, and graceful shutdowns; local and remote management options supported
- Protection features: Automatic Voltage Regulation (AVR) for voltage stabilization; surge protection to safeguard connected equipment
- Battery and runtime: Internal batteries provide short- to medium-duration backup to allow orderly shutdowns and continued operation during short outages
- Connectors and interfaces: Network management via NIC, plus standard power outlets configured to support critical devices; straightforward monitoring and control through compatible management software
- Efficiency: Designed to deliver reliable protection with energy-efficient operation, reducing overall operating costs
how to install Vertiv Liebert PSI5 UPS
- Unpack the unit and verify that all components, including the RDU120 NIC, are present and intact. Inspect the chassis for any shipping damage and ensure you have the appropriate mounting rails for your rack.
- Mount the PSI5 securely in your standard 19-inch rack using the supplied rails or brackets. Confirm that there is adequate clearance for ventilation and cable organization.
- Connect your critical devices to the UPS outlets, ensuring total load stays within the 990 W rating. Leave some headroom for in-rush and startup currents of connected equipment.
- Connect the UPS input power to a dedicated 120 VAC power circuit. Ensure the circuit is properly grounded and that electrical safety guidelines are followed.
- Install the RDU120 NIC card for network management. Connect the UPS to your network and configure alerts, monitoring, and shutdown policies using your preferred management software or the PSI5’s built-in interface.
- Power on the UPS and perform a basic configuration check. Verify communication with the NIC, run a self-test, and confirm that voltage regulation and surge protection are functioning as expected.
Frequently asked questions
- What does the PSI5 protect? The Vertiv Liebert PSI5 protects servers, network switches, storage devices, and other critical IT equipment from power outages, brownouts, sags, spikes, and transient disturbances, helping ensure data integrity and uptime.
- What comes with the inclusion of the RDU120 NIC? The RDU120 NIC provides remote monitoring and management capabilities, including alerts and graceful shutdowns across your network, enabling proactive power protection without onsite intervention.
- Can the PSI5 be mounted in a standard rack? Yes. The PSI5 is designed for standard 19-inch racks, facilitating compact, organized, and accessible deployment in IT cabinets and data centers.
- How do I monitor the UPS status? Use the RDU120 NIC for network-based monitoring. You can also access status information via compatible software or the local management interface for real-time measurements, event logs, and shutdown configuration.
- What is the typical runtime for 1100 VA / 990 W loads? Runtime varies with load. At lighter loads, you can expect longer run times; at heavier loads near the 990 W rating, runtime will be shorter. The PSI5 is designed to provide enough time for orderly shutdowns during short outages and to bridge longer outages with reduced loads.