Description
Vertiv Liebert PSI5 UPS - 5000VA Line Interactive, Rackmount
The Liebert PSI5 is a compact, Automatic Voltage Regulation (AVR) line-interactive UPS system designed for IT environments such as network closets and small data centers. It delivers reliable power protection for critical equipment with advanced AVR technology, ensuring that voltage fluctuations are corrected without unnecessary battery use. This model provides a clean, stable power source for servers, switches, storage devices, and network gear, helping to safeguard uptime, data integrity, and business continuity. With a focus on efficiency, reliability, and easy serviceability, the Liebert PSI5 is built to support growing IT deployments while minimizing maintenance overhead and total cost of ownership.
- Advanced AVR technology continuously monitors incoming power and automatically boosts or trims the voltage to keep output within a safe band. It reduces wear on connected equipment by avoiding battery discharge during minor fluctuations and prevents unnecessary shutdowns, ensuring smoother operation for critical IT workloads like virtualization, databases, and high-availability networking gear.
- Pure sine wave output on battery guarantees clean, stable power for modern IT loads. This ensures compatibility with multi-phase servers, high-performance storage systems, PCIe-based hardware, and virtualization platforms, minimizing waveform-related disturbances and providing reliable performance during outages.
- Rack-mountable 2U enclosure with 19-inch compatibility enables space-efficient deployment in network closets, equipment rooms, or small data centers. The compact footprint simplifies integration into existing infrastructure, while quiet operation and effective thermal management help maintain a productive work environment.
- Comprehensive management options with USB and RS-232 connectivity and optional network management cards for remote monitoring and graceful shutdowns. Autonomous shutdowns, event logs, and real-time status updates empower IT staff to manage power reliably from local consoles or centralized monitoring systems.
- Maintenance-friendly design with replaceable battery cartridges and straightforward serviceability that reduces downtime and extends system life. Field-replaceable batteries simplify periodic maintenance, extend runtime reliability, and support longer service intervals to keep your IT environment protected without frequent outages.
Technical Details of Vertiv Liebert PSI5 UPS - 5000VA Line Interactive, Rackmount
- Capacity: 5000 VA / approximately 4500 W, providing ample headroom for small IT racks that include servers, switches, NAS, and storage expansion.
- Output waveform: Pure sine wave on battery; seamless transfer between on-line mains operation and battery mode to preserve uptime and protect sensitive loads during power disturbances.
- Input voltage and frequency: 100–240 VAC auto-sensing input with 50/60 Hz operation, enabling flexible deployment across regional power standards without manual reconfiguration.
- Output voltage: 230 VAC nominal (typical), with tight voltage regulation to maintain stable power delivery to connected equipment.
- Form factor and mounting: 2U rack-mountable enclosure designed for standard 19-inch racks, with included mounting rails for secure installation in IT cabinets or freestanding environments.
- Interfaces and monitoring: USB and RS-232 communication ports; optional network management card for remote monitoring, SNMP, and centralized shutdown capabilities.
- Power management features: Automatic Voltage Regulation (AVR) with boost and trim functions, surge protection, EMI/RFI filtering, and user-friendly status indicators and audible alarms to keep operators informed of power conditions.
- Battery and maintenance: Lead-acid batteries with replaceable cartridges, enabling straightforward field maintenance and extended service life without major downtime or full unit replacement.
- Efficiency and reliability: Energy-efficient design optimized for IT workloads, designed for continuous operation in network environments with robust protection against surges, outages, and irregular power.
- Operating environment notes: Built for IT closets and small data centers, offering reliable protection in space-constrained rack environments while maintaining performance in varying temperatures typical of equipment rooms.
How to install Vertiv Liebert PSI5 UPS
Begin by selecting a clean, ventilated installation site inside a standard 19-inch rack or a secure equipment enclosure. Use the included mounting rails to attach the 2U PSI5 unit snugly to the rack, ensuring there is adequate clearance for cooling and cable access. Once mounted, connect the UPS to a dedicated AC circuit with proper grounding, following your local electrical codes and safety guidelines. Attach the battery cartridge if it is a separate module and ensure it is seated correctly and secured before powering the unit. Connect protected IT devices to the UPS outlets, and reserve one or more outlets for critical components that require uninterrupted operation during a power event. Connect the USB and/or RS-232 cables to a management workstation or server to enable local monitoring and alerting; if remote management is desired, install the optional network management card or use a compatible management server for SNMP-based monitoring and centralized shutdowns. Power on the UPS and perform a basic self-test to confirm that input power is recognized, status indicators are normal, and the AVR function is operational. Configure voltage regulation settings if needed, tailor the audible alarm preferences, and establish a test shutdown for one or more protected devices to validate graceful shutdown procedures. Finally, document the installation details, including location, circuit rating, outlet configuration, and maintenance schedule, so staff can perform routine battery checks and firmware updates in line with your IT governance policy.
Once installed, plan for routine maintenance: inspect the rack environment for adequate cooling, verify battery health through the UPS software or onboard indicators, and schedule firmware updates as offered by Vertiv. Regular battery health checks help ensure the system can sustain expected runtime during outages, while monitoring software provides real-time visibility into load, voltage regulation activity, and event history. For larger deployments or multi-rabbed environments, consider integrating the PSI5 into a broader power protection strategy that includes centralized monitoring and coordinated shutdowns for an orderly data center operation.
Frequently asked questions
- What is the Liebert PSI5 UPS used for? It provides reliable power protection for servers, networking gear, storage devices, and other IT equipment in network closets and small data centers, safeguarding uptime and data integrity during power disturbances.
- What is the capacity? The unit is rated at 5000 VA (approximately 4500 W), offering sufficient headroom to support typical small IT racks with critical devices and essential peripherals.
- Does it generate a pure sine wave? Yes. The PSI5 delivers pure sine wave output on battery to ensure clean, stable power for sensitive IT hardware and virtualization workloads.
- What inputs/outputs does it have? It includes USB and RS-232 interfaces for local monitoring; an optional network management card enables remote management, SNMP, and centralized shutdown. It supports common input standards (100–240 VAC) and provides 230 VAC output in nominal operation.
- Can I replace the batteries? Yes. The PSI5 uses field-serviceable, replaceable battery cartridges designed to simplify maintenance and extend the system’s usable life without replacing the entire unit.
- Is it easy to install in a rack? Yes. The unit is designed for standard 19-inch racks and typically occupies 2U of rack space, with included mounting rails and straightforward cable management for a clean, scalable installation.
Customer reviews
Showing - Of Reviews