Description
Vertiv Liebert PSI5 Replacement Internal Battery Kit – PSI5-1500RT120 TAA
Upgrade the resilience of your power protection with the Vertiv Liebert PSI5 Replacement Internal Battery Kit for the PSI5-1500RT120 UPS. The PSI5-1500BATKITTAA is designed to deliver longer battery run times for connected devices, helping to safeguard critical workloads during outages and minimize data loss. As a TAA-compliant solution, this internal, hot-swappable battery kit meets procurement standards while delivering dependable performance, safety, and ease of maintenance. Engineered for the Liebert PSI5 platform, this replacement kit ensures compatibility, safety, and seamless integration with your existing UPS ecosystem.
- Maximized runtime for essential devices: This replacement battery kit extends backup power for connected equipment, giving you more time to respond to outages and gracefully shut down systems without compromising data integrity.
- Hot-swappable, internal design for minimal downtime: The kit is engineered to allow battery replacement without halting the UPS or disconnecting connected loads, keeping downtime to a minimum and uptime to a maximum.
- Non-spillable VRLA technology for safe operation: The Valve Regulated Lead Acid chemistry is sealed, maintenance-free, and designed to prevent leaks, delivering dependable performance in a wide range of environments.
- TAA-compliant compatibility for government and commercial markets: This battery kit meets Trade Agreements Act requirements, broadening its applicability across sectors that require compliance with government procurement standards.
- Optimized for PSI5-1500RT120 performance: Engineered to fit precisely with the PSI5-1500RT120, the kit maintains proper charging profiles, safety interlocks, and reliable operation within the Liebert PSI5 system.
Technical Details of PSI5-1500BATKITTAA
- Part Number: PSI5-1500BATKITTAA
- Compatibility: Vertiv Liebert PSI5-1500RT120 UPS
- Battery Type: Lead-Acid, Valve-Regulated (VRLA), Non-Spillable
- Configuration: Internal Battery Kit, Hot-Swappable
- Compliance: TAA Compliant
- Manufacturer: Vertiv
How to Install PSI5 Replacement Internal Battery Kit
Installing the PSI5 replacement battery kit is designed to be straightforward for technicians familiar with Liebert UPS systems. The steps below outline the typical process to replace the internal battery kit while minimizing downtime and preserving load protection during the upgrade.
Step 1: Power down and prepare the system. Begin by shutting down all connected equipment and safely powering off the PSI5-1500RT120 UPS according to the manufacturer’s guidelines. Unplug the UPS from the wall outlet to eliminate any residual energy in the system.
Step 2: Access the battery compartment. Remove the service access panel or enclosure cover following the Liebert PSI5 user manual. Ensure you are working in a dry, clean environment and that the area is free from potential hazards.
Step 3: Disconnect the existing battery connections. Carefully release the battery connectors and take note of the wiring arrangement to ensure correct reattachment of the replacement kit. Use appropriate insulated tools and avoid pinching cables during removal.
Step 4: Remove the old battery module and install the new kit. Slide the PSI5-1500BATKITTAA into the internal bay, aligning mounting points and connectors precisely with the UPS docking points. Reconnect the battery harness, ensuring each connector seats firmly and that no wires are loose or stressed.
Step 5: Re-seal and restore power. Replace the battery compartment cover and secure it with the appropriate fasteners. Restore power by reconnecting the UPS to the wall outlet, and ensure all indicators return to normal states on the front panel.
Step 6: Verify operation and run a self-test. Once powered, run a self-test or diagnostics through the UPS interface to confirm healthy battery status, expected runtime, and proper charging behavior. Monitor for any warning or fault indicators and address them according to the user manual.
Step 7: Resume normal operations. After validating the battery kit’s performance, re-enroll the UPS in its normal monitoring workflow. If you use network management software, check that the PSI5-1500BATKITTAA is being reported correctly and that runtime estimates reflect the refreshed battery capacity.
Additional notes for installation: Always follow proper lockout/tagout procedures and consult the official Liebert PSI5 manuals for any model-specific instructions. If you are unsure about handling battery components or accessing internal hardware, contact a qualified technician or Vertiv support for installation assistance. Proper handling and disposal of the old battery kit in accordance with local regulations is recommended to ensure environmental safety.
Frequently Asked Questions
-
Is the PSI5-1500BATKITTAA compatible with my PSI5-1500RT120?
Yes. The battery kit is specifically designed to replace internal batteries in the PSI5-1500RT120 UPS, ensuring proper fit, electrical interface, and charging compatibility.
-
What does hot-swappable mean for this kit?
Hot-swappable means you can replace the battery module without powering down the connected loads or the entire UPS. This minimizes downtime and keeps critical systems protected during maintenance.
-
Is the battery kit VRLA and non-spillable?
Yes. The kit uses Valve Regulated Lead Acid (VRLA) chemistry, which is sealed and non-spillable, providing safe operation with minimal maintenance requirements.
-
Why is TAA compliance important?
TAA compliance ensures the product meets Trade Agreements Act requirements, which is essential for government procurement and compliance with many corporate purchasing policies. It also supports global procurement needs across multiple markets.
-
How does runtime improve after installing a replacement kit?
Runtime improvements depend on the load and the age of the previous battery. Replacing aging internal batteries with a new kit typically restores or improves expected runtime as outlined by the UPS's runtime charts and specifications.