Description
Vertiv Liebert TAA 48V External Battery Cabinet for Liebert GXT5 VRLA UPS
The Vertiv Liebert TAA 48V External Battery Cabinet is a purpose-built solution that powers resilience in critical environments. Engineered to work seamlessly with Liebert GXT5 VRLA UPS systems, this external cabinet expands runtime and provides scalable backup power when outages strike. Built for reliability in data centers, server rooms, healthcare facilities, and industrial settings, the Liebert TAA cabinet helps you protect mission-critical loads, maintain uptime, and safeguard business continuity even during extended power disturbances. Its robust construction, modular design, and advanced battery management deliver dependable performance, simplify maintenance, and enable flexible installations in compact footprints. If you’re looking to optimize uptime, improve service availability, and future-proof your UPS configuration, the Liebert TAA 48V External Battery Cabinet is a trusted choice that complements Liebert GXT5 technology with proven efficiency and ease of use.
- Extended runtime with scalable capacity: By adding the Liebert TAA external cabinet to a Liebert GXT5 VRLA UPS, you can significantly increase backup time to meet your specific load profile. The modular design allows you to scale capacity as requirements evolve, enabling a tailored retention strategy for critical workloads without overbuilding your infrastructure. This scalability is ideal for facilities that experience variable power needs, downtime windows, or seasonal demand shifts, ensuring you stay online when it matters most.
- Rugged, purpose-built enclosure for harsh environments: The external cabinet features a robust steel enclosure with a durable powder-coated finish, designed to withstand the rigors of data centers, manufacturing floors, and healthcare settings. Its vented design promotes safe heat dissipation, while the sturdy construction protects delicate battery components from incidental impacts, dust, and humidity. This reliability reduces maintenancefrequency and extends service life in challenging operating conditions.
- Seamless Liebert GXT5 integration: Specifically engineered for Liebert GXT5 VRLA UPS systems, the TAA cabinet connects quickly through Liebert’s standard battery harnesses and monitoring interfaces. This tight integration ensures coordinated charging, optimized battery management, and synchronized shutdown behavior during outages. The result is a clean, predictable power profile that protects critical equipment and maintains consistency across your power infrastructure.
- VRLA battery technology with smart management: The cabinet houses Valve Regulated Lead Acid (VRLA) cells configured for reliable, maintenance-friendly operation. With built-in battery management features, the system maintains proper charging voltage, monitors temperature, and provides alarms for out-of-tolerance conditions. This intelligent oversight helps maximize battery life, reduces the risk of unexpected failures, and supports proactive maintenance planning.
- Easy installation, maintenance, and safety: The Liebert TAA cabinet is designed for straightforward installation beside or near the Liebert GXT5 UPS, with clear labeling and accessible battery compartments. It supports safe, tool-light maintenance, including straightforward battery replacement. Comprehensive safety features—grounding, short-circuit protection, and status indicators—ensure a secure operating environment and minimize downtime during service events.
Technical Details of Vertiv Liebert TAA 48V External Battery Cabinet
- Enclosure and materials: Heavy-duty steel exterior with powder-coated finish for durability in commercial environments.
- Battery technology: Valve Regulated Lead Acid (VRLA) cells configured for 48V output.
- Voltage and electrical interface: 48V DC nominal, designed to pair with Liebert GXT5 UPS battery harnesses and management circuitry.
- Compatibility: Specifically designed for use with Liebert GXT5 VRLA UPS systems to extend runtime and optimize overall UPS performance.
- Runtime scalability: Modular design allows incremental capacity additions to meet changing load and downtime requirements.
- Monitoring and safety: Integrated indicators and monitoring interfaces aligned with Liebert monitoring ecosystems; includes protection, alarms, and thermal management safeguards.
- Installation options: Suited for near-line cabinet placement with flexibility for adjacent or nearby mounting, supporting both floor-standing and space-constrained layouts.
- Environmental considerations: Ventilated enclosure to aid heat dissipation; designed for indoor environments typical of data centers and server rooms.
- Maintenance: Accessible battery compartments and straightforward replacement procedures to minimize downtime during service events.
How to Install Vertiv Liebert TAA 48V External Battery Cabinet
Preparing for installation starts with confirming compatibility and planning placement. Ensure the Liebert GXT5 UPS is powered down and that you have the appropriate battery harness connections and monitoring interfaces. Identify a location that provides adequate ventilation, defined clearance for service access, and proximity to the UPS to minimize cabling length and impedance. Review the cabinet labeling and wiring diagrams before beginning to reduce the risk of errors during connection.
Step 1: Position the external cabinet in a suitable location. Align it near the Liebert GXT5 unit to shorten cable runs and facilitate monitoring. Check clearances for safe operation, maintenance access, and airflow. If mounting is required, follow your facility’s guidelines for floor-standing or rack-adjacent installation and secure the cabinet according to the manufacturer’s recommendations.
Step 2: Connect power and grounding. Attach the cabinet’s grounding conductor to the facility ground, then connect the 48V DC battery output to the appropriate terminals on the Liebert GXT5 battery harness. Use the provided torque specifications and proper connectors to ensure a secure, low-resistance connection. Double-check polarity and verify that all connections are snug before applying power.
Step 3: Integrate monitoring and communication. Link the cabinet to the Liebert GXT5 monitoring ecosystem as directed in the installation guide. This enables battery status data, temperature readings, and alarms to flow into the UPS management console, providing a unified view of runtime, health, and potential fault conditions across the power system.
Step 4: Perform a system initialization. Power up the Liebert GXT5 UPS and the external cabinet in sequence, allowing the battery management system to initialize. Initiate a controlled battery test or runtime simulation as recommended by the manufacturer. Observe the indicators and logs for any abnormal conditions, and address alarms promptly if they appear.
Step 5: Configure runtime targets and alarms. Set target runtimes based on critical load profiles and business requirements. Establish alarm thresholds for temperature, voltage, and impedance, and enable alert routing to facilities staff or a monitoring service. Document the configuration for future maintenance and audits.
Step 6: Validate performance and safety. Run a full-load test if approved by your safety policies. Confirm that the UPS and external cabinet deliver the expected backup duration under simulated outages. Verify that cooling, ventilation, and accessibility remain within safe operating parameters. Once validated, update your maintenance calendar with periodic battery checks and preventive service windows.
Note: Installation details may vary by model revision and facility environment. Always consult the official installation guide and datasheets for exact wiring schemes, torque specifications, and safety instructions. If you are uncertain about any step, contact Vertiv support or a qualified electrician to ensure proper, code-compliant installation.
Frequently asked questions
- What is the purpose of the Vertiv Liebert TAA 48V External Battery Cabinet? It serves as an external battery module that extends runtime for Liebert GXT5 VRLA UPS systems, enabling longer backup periods and greater resilience for critical loads during power outages.
- Is this cabinet compatible with all Liebert GXT5 configurations? It is designed to work with Liebert GXT5 VRLA UPS systems. For optimal results, verify compatibility with your specific GXT5 model and battery harness configuration in the official documentation.
- Can I upgrade runtime incrementally? Yes. The external cabinet is designed to be added progressively, allowing you to scale backup capacity as your load or uptime requirements grow over time.
- What maintenance considerations are there? VRLA batteries require periodic inspection, temperature control, and timely replacement when end-of-life indicators appear. The cabinet’s monitoring features help you track battery health and trigger preventive service as needed.
- Where can I find exact dimensions, weight, and electrical specifications? Consult the latest Vertiv Liebert TAA datasheet and the product’s specifications in the official documentation or on the Synnex/Vendor spec pages for precise numbers and certification details.
Customer reviews
Showing - Of Reviews