Description
Vertiv Liebert TAA 72V External Battery Cabinet for Liebert GXT5 VRLA UPS
The Vertiv Liebert TAA 72V External Battery Cabinet is a groundbreaking solution crafted to maximize uptime for Liebert GXT5 VRLA UPS systems. Designed for critical power environments, this TAA-compliant enclosure extends runtime by adding scalable energy storage that supports longer backup periods during outages, power disturbances, or scheduled maintenance. Built with industrial-grade materials and precise engineering, the 72V external cabinet delivers reliable, maintenance-friendly performance for data centers, healthcare facilities, financial services, and edge computing deployments where every second of power continuity matters. Whether you’re protecting servers, networking gear, or sensitive hardware, this external battery cabinet integrates seamlessly with Liebert GXT5 systems to preserve equipment, protect data integrity, and ensure a smooth recovery from unexpected outages. Optimized for efficiency, safety, and ease of installation, it stands as a cornerstone of a resilient power strategy in today’s mission-critical environments.
- Extended runtime for critical loads: Demands of modern IT require longer backup windows, and the 72V external battery cabinet delivers extended runtime for essential systems when mains power is interrupted, reducing the risk of data loss and service disruption.
- TAA-compliant for federal and public sector procurement: This model meets the Trade Agreements Act requirements, making it a trusted option for government and large enterprise projects that demand compliant backup power solutions.
- 72V VRLA battery architecture: High-density 72V DC battery technology provides robust, reliable energy storage with proven lead-acid chemistry, designed to pair flawlessly with Liebert GXT5 VRLA UPS for dependable resilience.
- Modular, scalable design: The external cabinet is designed to work alongside Liebert GXT5 systems, enabling you to add storage capacity as your load increases without major overhauls to your power infrastructure.
- Rugged, secure enclosure with practical maintenance features: The cabinet’s steel construction offers durable protection with secure access, and its design supports straightforward maintenance and battery serviceability, minimizing downtime during battery replacements.
Technical Details of Vertiv Liebert TAA 72V External Battery Cabinet for Liebert GXT5 VRLA UPS
- Product type: External battery cabinet designed for Liebert GXT5 VRLA UPS
- Voltage and chemistry: 72V DC, VRLA (Valve-Regulated Lead-Acid) battery technology
- Compliance: TAA-compliant enclosure suitable for government and enterprise procurement
- Compatibility: Specifically engineered for Liebert GXT5 VRLA UPS modules to extend runtime and preserve load integrity
- Enclosure and build: Rugged steel cabinet with secure access and proper ventilation to maintain safe operating temperatures
- Configuration: Scalable external storage that can be added to existing Liebert GXT5 configurations for increased backup capacity
How to install Vertiv Liebert TAA 72V External Battery Cabinet
Preparing for installation starts with confirming compatibility and ensuring a clean, ambient environment for the battery cabinet. Verify that your Liebert GXT5 VRLA UPS is configured to accept an external 72V battery cabinet and that there is sufficient space for the enclosure near the UPS with appropriate clearance for airflow and access.
1. Power down and isolate: Before any connections, safely shut down connected loads and switch off the Liebert GXT5 system according to the manufacturer’s instructions. Lockout/tagout procedures should be followed if applicable to your site.
2. Position and secure the cabinet: Move the 72V external battery cabinet into its designated location near the Liebert GXT5. Ensure the surface is level and stable, and that there is adequate ventilation to prevent overheating. If floor mounting is used, secure the cabinet according to local electrical and building codes.
3. Connect interconnection cabling: Use the approved interconnection cable provided or specified by Vertiv to link the Liebert GXT5 UPS to the external battery cabinet. Follow the exact wiring sequence and polarity as described in the installation guide to ensure proper communication and safe operation. Confirm all connections are snug and secure.
4. Grounding and safety checks: Verify proper grounding for both the UPS and the external cabinet. Inspect the enclosure for any visible damage, loose components, or signs of wear. Ensure that cabinet doors are properly closed and locked to protect the batteries and prevent unauthorized access.
5. System configuration: Power on the Liebert GXT5 and navigate to the battery configuration settings. Enable external battery cabinet support if required by firmware, and run any built-in self-tests to verify successful recognition of the 72V cabinet. If firmware updates are recommended, apply them before full-load testing.
6. Initial load testing: With the external cabinet connected, perform a controlled load test to confirm that the Liebert GXT5 can gracefully transition to external battery power and that runtime extension functions as expected. Monitor system temperatures, voltage levels, and battery health indicators during the test.
7. Documentation and maintenance planning: Record the installation details, including cabinet model, serial numbers, firmware versions, and test results. Establish a maintenance plan that includes regular battery health checks, voltage checks, and periodic replacements based on manufacturer recommendations and site conditions.
By following these steps, you ensure a safe, compliant, and effective deployment of the Vertiv Liebert TAA 72V External Battery Cabinet with your Liebert GXT5 VRLA UPS. The result is a resilient, scalable power solution that protects critical loads and maintains service continuity across a range of operating environments.
Frequently asked questions
- What is the purpose of the 72V external battery cabinet? It provides additional runtime for the Liebert GXT5 VRLA UPS, allowing critical loads to remain powered longer during outages, while preserving uptime and data integrity.
- Is the cabinet compatible with all Liebert GXT5 configurations? The cabinet is designed to integrate with Liebert GXT5 VRLA UPS systems and is intended to complement supported configurations. Always verify compatibility with your model and firmware prior to purchase.
- What does TAA-compliant mean for procurement? TAA compliance indicates the cabinet meets requirements for federal and state procurement, often a key consideration for government projects and large enterprises seeking approved, auditable backup solutions.
- How do I know when the batteries should be replaced? Battery health should be monitored through the UPS management interface, which can indicate capacity, health status, and estimated remaining runtime. Routine maintenance every few years is typically recommended, depending on usage and environmental conditions.
- Can the external cabinet be expanded in the future? Yes, one of the key benefits of a modular design is scalability. You can add external battery cabinets to increase runtime as system load grows, subject to UPS specifications and firmware support.
- What safety considerations should I observe during installation? Observe standard electrical safety practices, ensure proper grounding, avoid placing the cabinet in damp or poorly ventilated areas, and follow local codes and manufacturer guidelines for electrical work and battery handling.
- How is maintenance performed on the external battery cabinet? Routine maintenance includes battery health checks, connection inspections, and assurance that ventilation paths remain unobstructed. Replace batteries per manufacturer recommendations and use only approved replacement modules.
- Will installation affect warranty? Installing an official Vertiv accessory as designed for Liebert GXT5 should preserve the warranty, provided installation follows the manufacturer’s guidelines and all required procedures are followed. Always confirm with Vertiv if you have questions about warranty implications.
Customer reviews
Showing - Of Reviews