Vertiv Liebert TDU - 3440VA/3440W 120VAC|Step Down Transformer/Voltage Converter

VERTIVSKU: 5546102

Price:
Sale price$1,282.59

Description

Vertiv Liebert TDU - 3440VA/3440W 120VAC Step-Down Transformer & Voltage Converter

The Vertiv Liebert TDU delivers dependable energy conversion for demanding power environments. This 3440VA/3440W, 120VAC step-down transformer and voltage converter is engineered to take 208VAC or 240VAC input and convert it to a stable 120VAC output, enabling seamless operation with high-capacity single-phase UPS systems. Ideal for data centers, telecommunications rooms, laboratories, and industrial settings, the Liebert TDU helps protect sensitive electronics from voltage fluctuations, sags, and surges while supporting consistent performance under load. Its robust construction, reliable regulation, and straightforward integration make it a trusted choice for engineers seeking to maximize uptime and safeguard critical loads that depend on precise, clean power. With a focus on efficiency and durability, this transformer/voltage converter is designed to operate in challenging environments and deliver steady, clean 120V power to essential equipment.

  • Compatibility with high-capacity UPS systems: The Liebert TDU is designed to integrate with 5kVA+ single-phase UPS configurations that require an input of 208VAC or 240VAC, producing a reliable 120VAC output for connected loads. This compatibility helps bridge the gap between UPS specifications and downstream devices, ensuring critical systems receive the correct voltage without the need for extensive reconfigurations. By providing a dedicated path from higher-voltage inputs to a standard 120V feed, it minimizes the risk of undervoltage and provides a smooth transition during power events.
  • Efficient power conversion with high regulation: This transformer delivers efficient conversion with a focus on stable voltage regulation, maintaining a tight tolerance at varying loads. The result is minimal voltage drift, reduced thermal stress on downstream equipment, and improved performance of sensitive devices such as servers, network gear, and clinical instruments. The 3440VA/3440W rating ensures ample headroom for peak loads while maintaining efficiency, helping to lower energy waste and cooling requirements in data-center environments.
  • Robust protection and power quality: Built to shield critical equipment from common power quality issues, the Liebert TDU helps guard against voltage sags, surges, and transient spikes that can shorten component lifespans or cause unexpected downtime. By delivering a clean, regulated 120VAC output, it supports reliable operation of sensitive electronics and reduces the likelihood of nuisance faults caused by fluctuating mains voltages. Optional grounding and protection features work with existing facility protections to create a safer, more resilient power path.
  • Easy integration and reliable operation: The Liebert TDU is designed for straightforward deployment alongside existing UPS and electrical infrastructure. Its compact footprint and durable enclosure enable flexible installation in racks, closets, or dedicated electrical rooms. With minimal wiring complexity and a focus on reliability, technicians can bring up a stable 120VAC supply quickly, reducing site downtime and enabling consistent performance for critical loads across shift changes and maintenance windows.
  • Trusted Vertiv support and long-term value: As part of the Vertiv Liebert family, this transformer/voltage converter benefits from Vertiv's global service network, spare parts accessibility, and long-term product availability. Organizations gain peace of mind through dependable performance, documented service options, and warranty coverage designed to protect their power infrastructure investment over years of operation.

Technical Details of Vertiv Liebert TDU - 3440VA/3440W 120VAC

  • Get this information from the "specifications" section of the product from https://ec.synnex.com/ using product "UPC" or "SKU" as reference

How to install Vertiv Liebert TDU

Installing the Vertiv Liebert TDU should be performed by qualified personnel following all applicable electrical codes and safety practices. The steps below provide a high-level guide to typical installation scenarios and are not a substitute for the official installation manual.

  • Power down all connected equipment and isolate the installation area to prevent accidental energization during wiring. Verify that you have the correct input supply (208VAC or 240VAC) and the appropriate output connections for 120VAC loads.
  • Mount the Liebert TDU in a suitable enclosure or location with adequate ventilation. Ensure there is sufficient clearance around the unit for heat dissipation and safe cable routing. Avoid placing the transformer in areas with excessive moisture, dust, or restricted airflow.
  • Connect the input conductors from the facility power source to the TDU's input terminals as specified in the installation manual. Ensure proper identification of line, neutral, and ground connections, and confirm that all connections are secure and tightened to the recommended torque specifications.
  • Connect the output conductors from the TDU to the protected loads that require 120VAC. Maintain correct polarity and grounding, and avoid overloading the transformer beyond its 3440VA/3440W rating. Use appropriately rated cables and protection devices as required by code.
  • Perform a controlled power-up sequence: verify all interlocks, check for proper voltage regulation at the output, and monitor for abnormal temperatures or audible indicators. Confirm that connected equipment starts normally and that protection devices (e.g., circuit breakers, fuses) remain in acceptable operating ranges. Document configuration details and test results for ongoing maintenance.

Frequently asked questions

  • Q: What input voltages does the Vertiv Liebert TDU support?
    A: The unit is designed to accept 208VAC or 240VAC input and provides a stable 120VAC output to downstream equipment. This makes it suitable for data centers and facilities with high-voltage UPS systems requiring a lower, regulated output.
  • Q: Which loads can I power with the Liebert TDU?
    A: The transformer/voltage converter is rated at 3440VA/3440W, so it can support a broad range of critical loads that total up to that rating. It is intended to work in conjunction with high-capacity UPS configurations to deliver a reliable 120VAC supply to servers, networking gear, and other sensitive equipment.
  • Q: Does the Liebert TDU provide protection against power surges?
    A: The device is designed to improve power quality for connected loads, helping to mitigate some surges and sags through regulated output. For comprehensive protection, it should be used in concert with a full UPS and facility surge protection strategy.
  • Q: Is installation covered by a warranty?
    A: Warranty terms vary by region and distributor. Vertiv typically offers standard warranty coverage on Liebert products, with options for extended service contracts through authorized channels. Check with your supplier for exact terms and fulfillment.

Customer reviews

(0)

0 Out of 5 Stars


5 Stars
0
4 Stars
0
3 Stars
0
2 Stars
0
1 Star
0


Showing - Of Reviews