Description
Vertiv Liebert TDU - 5050VA/5050W 120VAC | Step Down Transformer / Voltage Converter
The Vertiv Liebert TDU is a robust, purpose-built voltage conversion and distribution solution designed for professionals who rely on consistent, clean power for critical equipment. This 5050VA/5050W step-down transformer converts higher input voltages of 208 VAC or 240 VAC down to a stable 120 VAC output, enabling reliable operation for servers, networking gear, medical devices, lab instrumentation, digital signage, and other sensitive electronics. As a true Transformer Distribution Unit from Vertiv Liebert, the TDU blends dependable power conversion with practical distribution capabilities, delivering peace of mind in data centers, control rooms, laboratories, and professional workspaces where uptime matters. Built to withstand demanding conditions, it combines a durable enclosure, straightforward wiring, and clear labeling to simplify installation, monitoring, and routine maintenance while supporting safe, compliant electrical practices. If you need a reliable, space-efficient solution to bridge non-120V mains to your 120V devices without the complexity of larger UPS systems, the Liebert TDU is designed to deliver consistent voltage, dependable protection, and effortless integration into a wide range of environments.
- Reliable voltage conversion with 120V output: The Liebert TDU steps down 208 VAC or 240 VAC input to a steady 120 VAC output, helping critical devices operate within their specified voltage range and reducing risks from voltage fluctuations, sags, and brownouts that can compromise performance or shorten equipment life.
- High-capacity power for dense equipment loads: With a 5050 VA / 5050 W rating, this transformer is built to support multiple devices or a cluster of high-demand components. It provides the headroom needed for startup surges and peak loads, ensuring equipment stays within safe operating limits even during demand spikes.
- Durable, space‑efficient design: The Liebert TDU is engineered for professional environments, featuring a rugged enclosure suitable for rack-adjacent or floor deployments. Its compact footprint fits in data centers, laboratories, or offices where space is at a premium, while still offering robust protection for connected gear.
- Integrated power distribution benefits: Beyond simple voltage conversion, the Liebert TDU acts as a practical power distribution solution for critical equipment, simplifying wiring layouts and reducing clutter. Clear labeling and straightforward wiring guidance help technicians connect loads safely and efficiently.
- Engineer‑trusted reliability and support: As part of the Vertiv Liebert family, the TDU benefits from the brand’s long-standing reputation for dependable power management, durable construction, and global support. This makes it a sensible long‑term investment for IT rooms, clinical labs, or control centers where downtime is not an option.
Technical Details of Vertiv Liebert TDU
- Power rating: 5050 VA / 5050 W
- Input voltage: 208 VAC or 240 VAC
- Output voltage: 120 VAC
- Configuration: Step-down transformer / voltage converter with distribution capabilities
- Designed for use with critical equipment in data centers, offices, labs, and other professional environments
How to install Vertiv Liebert TDU
- Before you begin, ensure the power is completely shut off and that you comply with all local electrical codes and safety practices. Review any installation manuals or labeling on the unit for wiring references.
- Choose a stable, well-ventilated location with enough clearance for cooling, access to connections, and ease of maintenance. The Liebert TDU can be placed near the equipment it serves, either on the floor or in a dedicated cabinet area, as appropriate.
- Plan input and output routing. Identify your 208 VAC and/or 240 VAC input supply and the 120 VAC loads that will be fed by the TDU. Ensure that wiring paths minimize exposure to heat sources and physical damage while allowing for safe serviceability.
- Connect the input side of the Liebert TDU to the appropriate power source according to the unit’s labeling and wiring diagram. Use proper gauge wiring and secure connections to prevent loose contacts. Grounding should be established in accordance with local electrical codes.
- Connect your 120 VAC devices to the TDU’s output connections, taking care to distribute the load evenly and avoid exceeding the rated capacity. Double‑check polarity and grounding for all connected equipment.
- Power on the system and verify output. Use a voltmeter to confirm that the output is delivering a stable 120 VAC under normal load conditions. Observe the unit for any unusual warmth, noise, or smells, and verify that all devices operate as expected.
- Document installation details and schedule routine inspections. Maintain clear labeling of input and output circuits, and keep spare parts or service contacts readily available to minimize downtime in case of maintenance or component replacement.
Frequently asked questions
-
Q: What does the Vertiv Liebert TDU do?
A: It functions as a step-down transformer and distribution unit, converting higher line voltages of 208 VAC or 240 VAC down to a stable 120 VAC output to power compatible devices reliably. -
Q: What is the power rating of the Liebert TDU?
A: The unit is rated at 5050 VA / 5050 W, providing substantial headroom for multiple loads and startup surges while delivering consistent voltage to connected equipment. -
Q: Which voltages are supported?
A: Input voltages supported are 208 VAC or 240 VAC, with a 120 VAC output for 120-volt devices. -
Q: Is this suitable for data centers or professional offices?
A: Yes. It is designed for critical devices in data centers, labs, and professional offices where reliable, conditioned power is essential, and where non-120V feed sources require conversion to 120V output. -
Q: How should I install the Liebert TDU?
A: Install in a well-ventilated area, follow local electrical codes, connect the 208/240 VAC input to the unit, wire the 120 VAC loads to the output, verify output voltage, and perform routine maintenance per Vertiv guidelines.