Vertiv PowerIT VP7U60A2 Switched Outlet Level Monitoring HD rPDU, Vertical, Three Phase, 36 Combination C13/C19 Outlets, 60/63A, 240/415V WYE, 0U

VertivSKU: 14575238

Price:
Sale price$4,062.71

Description

Vertiv PowerIT VP7U60A2 Switched Outlet Level Monitoring HD rPDU

Discover advanced power management for high-density IT environments with the Vertiv PowerIT VP7U60A2 Switched Outlet Level Monitoring rPDU. This high-performance, 0U vertical unit is engineered for data centers, server rooms, and edge deployments where space is at a premium and control is critical. The VP7U60A2 delivers precise, outlet-level visibility and control across a 36-outlet configuration, combining reliability, scalability, and smart monitoring in a compact footprint. Whether you’re powering racks of blades, dense storage arrays, or telecom gear, this rPDU provides the essential reliability and actionable insights that help you optimize energy use, reduce downtime, and streamline maintenance.

With three-phase 240/415V WYE input and a robust 60/63A rating, the VP7U60A2 distributes power efficiently while supporting the demanding workloads of modern IT environments. Its mixed C13 and C19 outlets accommodate a wide range of devices without the need for extra adapters, simplifying cable management and improving airflow within the cabinet. The combination of remote control, real-time outlet monitoring, and scalable analytics lets you implement granular power policies, set up automated alerts, and integrate power data into your DCIM workflows. The result is a smarter, safer, and more energy-efficient data center that can scale with your growth and changing IT priorities.

  • Comprehensive outlet-level control and monitoring: Each outlet can be switched remotely, with real-time data on current, voltage, and status. This enables precise workload distribution, rapid fault isolation, and automated power policies that protect critical gear while reducing energy waste and operating costs.
  • 36-outlet density with C13/C19 versatility: A compact, 0U vertical footprint houses 36 receptacles in a flexible mix of C13 and C19 sockets, simplifying rack wiring and enabling you to power a broad spectrum of equipment from servers to storage to networking devices without clutter or adapters.
  • Three-phase power delivery with high capacity: Designed for 240/415V WYE systems, the VP7U60A2 supports 60/63A input and delivers up to 43.4 kW of total power across all outlets, meeting the demands of dense compute nodes and multi-node racks while maintaining stable, clean power delivery.
  • Space-saving vertical, zero-U footprint: The 0U design integrates seamlessly into standard racks, maximizing usable horizontal space for airflow and cable management, while still providing full access to outlets and management interfaces for maintenance and upgrades.
  • Robust management and protection: Built-in outlet-level monitoring, secure remote management, and protective features offer proactive insight into power conditions, helping you prevent overloads and outages while supporting compliance with energy and safety standards.

Technical Details of Vertiv PowerIT VP7U60A2

  • Model: VP7U60A2
  • Form factor: 0U vertical rPDU
  • Outlet count: 36 (C13/C19 combination)
  • Phases: 3-phase
  • Voltage: 240/415 V (WYE)
  • Current: 60/63 A
  • Power capacity: up to 43.4 kW
  • Monitoring: outlet-level switched monitoring
  • Mounting: vertical rack-mountable
  • Management interface: built-in remote management capabilities for analytics and control

How to install Vertiv PowerIT VP7U60A2

  • Plan your rack layout: Verify that your cabinet can accommodate a vertical 0U rPDU and identify the best rear-access point for cabling, ensuring there is sufficient clearance for airflow and maintenance.
  • Verify electrical requirements: Confirm that your data center power distribution is configured for 240/415V three-phase power with a 60/63A supply, and ensure the circuit breakers and feeders meet the VP7U60A2’s current rating.
  • Mount the rPDU: Install the VP7U60A2 in the desired rack position, aligning with the rear rails. Secure the unit according to the rack manufacturer’s guidelines to ensure stability and proper grounding.
  • Connect power and network: Attach the input power cables to the appropriate sources and connect the rPDU’s management interface to your network according to the user manual. Ensure secure network access for monitoring and control.
  • Populate outlets and manage loads: Begin connecting devices to the C13 and C19 outlets, distributing critical and non-critical equipment according to your power policy. Configure outlet-level monitoring thresholds and alerts via the management interface as soon as devices are connected.
  • Configure monitoring and firmware: Access the built-in management interface to set up alert thresholds, user access controls, and firmware updates. Regularly review power usage data and adjust policies to optimize efficiency and protection.
  • Test and validate: Power on connected equipment, verify that each outlet reports status correctly, and confirm that remote switching functions operate as intended. Conduct a simulated surge or fault scenario to validate alerting and failover processes.

Frequently asked questions

  • What outlets are included on the VP7U60A2? The unit provides 36 outlets configured as a mix of C13 and C19 connectors to support a wide range of IT equipment without needing adapters, simplifying cable management and improving rack organization.
  • What is the maximum power capacity? The PowerIT VP7U60A2 delivers up to 43.4 kW of power across all outlets when supplied with up to 60/63A of three-phase power at 240/415V WYE, enabling dense rack deployments with reliable performance.
  • How does outlet-level monitoring work? Each outlet is individually monitored and can be switched on or off remotely. The monitoring data includes current, voltage, and status indicators, which can be used to implement automated power policies and to trigger alerts in case of abnormal conditions.
  • What mounting options are available? The VP7U60A2 is designed for 0U, vertical rack mounting, saving horizontal space in the rack and leaving ample room for cabling and airflow behind the equipment.
  • How do I access the management features? The unit includes an integrated management interface that can be accessed over the network. This interface provides real-time power analytics, outlet-level control, alert configuration, and integration with DCIM or data center management workflows.
  • What kind of environment is required? Install in a temperature- and humidity-controlled data center or edge environment that meets standard IT rackroom conditions. Ensure protection from dust and moisture and provide proper grounding and surge protection where applicable.

Customer reviews

(0)

0 Out of 5 Stars


5 Stars
0
4 Stars
0
3 Stars
0
2 Stars
0
1 Star
0


Showing - Of Reviews


You may also like

Recently viewed