Description
Vertiv Psi5 5kVA 4500W UPS — 208VAC RT Rack/Tower Online Power Solution
Power reliability is essential for protecting critical equipment and preserving business operations. The Vertiv Psi5 5kVA UPS delivers unwavering online, double-conversion protection for data centers, server rooms, telecom closets, and industrial control systems. Designed to run on 208 VAC and presented in a versatile rack/tower (RT) form factor, the Psi5 provides a clean, stable power output that shields sensitive devices from outages, voltage sags, surges, and waveform distortion. With scalable runtime options, intuitive management features, and robust protection, this UPS helps you minimize downtime, safeguard data integrity, and maintain service continuity even during utility disturbances.
- High-capacity power for critical loads: The Psi5 is rated at 5 kVA / 4500 W, delivering ample headroom to protect essential servers, storage, network gear, and control systems without overloading the unit.
- 208 VAC input/output for data-center compatibility: Optimized for 208 VAC environments, the UPS provides a stable, clean output that keeps equipment operating within specification during brownouts, sags, and minor power disturbances.
- Online double-conversion topology with pure sine wave: Delivers continuous, isolated power to every connected device, ensuring precise voltage and frequency regulation for sensitive electronics and mission-critical workloads.
- Versatile RT (Rack/Tower) form factor with scalable runtime: The compact 19-inch rack footprint can be deployed in standard data-center racks or configured as a tower, with options to add external battery cabinets for longer runtimes as demand grows.
- Advanced management and monitoring: Includes an intuitive LCD interface and multiple communication options (USB, network management compatibility) for proactive monitoring, remote control, and rapid response to power events.
Technical Details of Vertiv Psi5 5kVA 4500W, 208VAC, RT
- Capacity: 5 kVA / 4500 W
- Output Voltage: 208 VAC
- Input Voltage Range: Optimized for 208 VAC systems with tolerance for standard fluctuations typical in 208V installations
- Topology: Online (double-conversion) UPS
- Form Factor: Rack/Tower (RT); 19-inch rack-mountable chassis with flexible mounting options
- Efficiency: High-efficiency operation appropriate for online UPS systems, reducing energy waste and cooling needs
- Output Waveform: Pure sine wave for clean, compatible power to sensitive equipment
- Battery System: Replaceable/hot-swappable battery modules with support for external battery cabinets to extend runtime
- Management: Local LCD interface with status indicators; supports USB and network-enabled management via compatible accessories for remote monitoring
- Protection Features: Comprehensive protection against overload, short circuits, brownouts, and surges with automatic shutdown and alarm signaling
- Environmental Range: Designed for typical data-center environments with specified operating temperature and humidity ranges
- Certifications: Compatible with common safety and energy-efficiency standards and compliant with industry requirements for critical-power systems
How to install Vertiv Psi5 5kVA UPS
- Choose a location with solid, level support and adequate airflow. Ensure there is enough clearance for maintenance access and for cooling airflow around the unit.
- Mount the Psi5 in a standard 19-inch rack if rack-mountable configuration is selected, or prepare a stable floor support if using the tower setup. Use the appropriate mounting hardware supplied by Vertiv to secure the unit safely.
- Connect the input power to a dedicated, properly rated 208 VAC supply. Follow local electrical codes and use appropriate circuit protection (circuit breakers) to guard against faults.
- Connect critical loads to the UPS output outlets or to a clean-power distribution solution that is compatible with the Psi5’s outlets. Do not overload the UPS beyond its 4500 W rating; plan a load profile that leaves headroom for startup surges.
- Power on the unit and perform the built-in self-test using the LCD interface or the supported software tool. Configure basic settings such as input/output voltage references, alarm thresholds, and remote-management options. If you plan to extend runtime, install external battery cabinets and configure runtime expansion in the management interface.
Frequently asked questions
- Q: What is the primary use case for the Vertiv Psi5 5kVA UPS? A: It is designed to protect critical loads in data centers, server rooms, telecom equipment hubs, and industrial controls by providing clean, continuous power during outages and disturbances.
- Q: What voltage does it operate at? A: The Psi5 is configured for 208 VAC systems, suitable for many data-center and commercial installations that utilize 208V power distribution.
- Q: Can runtime be extended? A: Yes. The Psi5 supports hot-swappable internal batteries and can be expanded with external battery cabinets to meet longer runtime requirements for your critical loads.
- Q: How do I monitor the UPS and receive alerts? A: The unit includes a local LCD interface and supports remote monitoring via USB or network-compatible management options, enabling alerts, event logs, and configuration changes from a central management system.
- Q: How should I maintain the battery system? A: Regular maintenance includes periodic self-tests, battery health checks, and timely replacement of aging batteries to preserve runtime and reliability. Follow Vertiv’s service guidelines for battery replacements and disposal.
Customer reviews
Showing - Of Reviews