Vertiv Rack Mount Kit, Wall Mount for Vertiv Avocent ACS 800 Serial Console

AVOCENTSKU: 5467580

Price:
Sale price$87.47

Description

Vertiv Rack Mount Kit, Wall Mount for Vertiv Avocent ACS 800 Serial Console

The Vertiv Rack Mount Kit is the definitive wall-mount solution for securely installing the Vertiv Avocent ACS 800 Serial Console. Engineered for durable performance in demanding data center environments, this kit delivers a clean, organized, and accessible mounting option that maximizes floor and rack space. With a focus on secure retention, straightforward installation, and streamlined cable management, the Vertiv Rack Mount Kit helps IT teams maintain optimal airflow, reduce clutter, and simplify ongoing maintenance. It’s the ideal choice for new deployments and for upgrading existing Vertiv Avocent ACS 800 installations, providing a stable, professional mounting solution that keeps critical console hardware within easy reach for administrators, technicians, and operators alike. Whether you operate a small server room or a large data center, this wall-mount kit offers a practical, scalable approach to console management that aligns with Vertiv’s renowned reliability and engineering precision.

  • Robust steel construction with a durable, powder-coated finish that stands up to busy data centers and long-term use.
  • Precisely engineered for the ACS 800 Serial Console, delivering secure retention and a clean, unobtrusive profile that fits neatly on any wall or out-of-rack location.
  • Space-saving wall-mount design that frees rack space for other equipment while improving accessibility for diagnostics, maintenance, and programming tasks.
  • Integrated cable management features to reduce strain, simplify organization, and promote proper airflow around the ACS 800 console for thermal efficiency.
  • Easy installation with clear labeling and included mounting hardware, enabling rapid setup with common hand tools and minimal downtime.

Technical Details of Vertiv Rack Mount Kit, Wall Mount for Vertiv Avocent ACS 800 Serial Console

  • Purpose: Wall-mount rack kit designed for Vertiv Avocent ACS 800 Serial Console installations.
  • Material: Cold-rolled steel construction for strength and rigidity; powder-coated finish for corrosion resistance and a professional look.
  • Finish: Matte or semi-gloss powder coat in a neutral color to blend with standard data center environments.
  • Compatibility: Specifically engineered for the ACS 800 Serial Console; designed to secure the console firmly while preserving accessibility and ventilation.
  • Mounting: Wall-mount bracket system that supports secure attachment to solid walls or compatible backing structures; suitable for vertical or near-horizontal orientations as required by site layout.
  • Hardware: Includes mounting screws, brackets, and anchors suitable for concrete or wood stud installations; instructions provided for straightforward assembly.
  • Ventilation and cable management: Integrated pathways and channels to guide power and data cables, helping maintain airflow around the unit and reduce cable clutter.
  • Weight and dimensions: Varies by configuration; consult the product packaging or official specification sheet for exact measurements and weight for your SKU.
  • Operational considerations: Designed for continuous operation in data centers; built to endure frequent access and routine maintenance without compromising security or performance.

how to install Vertiv Rack Mount Kit

  • Prepare the installation site: Select a sturdy wall with solid backing (studs or concrete) and ensure there is adequate clearance for access and cable routing. Verify that the wall surface can support the combined weight of the ACS 800 Serial Console and the mounting kit when fully loaded.
  • Unpack and verify components: Lay out all brackets, mounting plates, screws, anchors, and any instruction sheets. Confirm that you have the correct hardware for your wall type and that the components are free of damage.
  • Attach mounting brackets to the ACS 800 Serial Console: Secure the console to the wall-mount brackets using the provided screws. Ensure the console is seated firmly, with no wobble, and that all fasteners are tightened to the manufacturer’s recommended torque.
  • Mark wall-anchor locations: Hold the mounted brackets against the chosen wall location and mark the exact hole positions for studs or anchors. Double-check alignment to guarantee a level installation and proper cable routing space.
  • Install wall anchors and mount the bracket: Drill pilot holes and set the anchors appropriate for your wall type (concrete or wood stud). Secure the wall-mount bracket to the wall using the included hardware, ensuring the bracket is perfectly level.
  • Secure the ACS 800 Serial Console to the wall-mount: Hang or anchor the console onto the wall-mount bracket, depending on the kit design, and tighten all fasteners to secure the device. Confirm that the console is stable and does not shift when touched.
  • Route and manage cables: Route power, management, and serial cables through the integrated channels, keeping cables neat and avoiding sharp bends. Leave sufficient slack for maintenance and future repositioning.
  • Test and verify: Power up the ACS 800 Serial Console and verify operational status. Check console accessibility, button responses, and ensure that ventilation around the unit is unobstructed for optimal cooling.

Frequently asked questions

  • Q: Is this wall-mount kit compatible with other Vertiv consoles besides the ACS 800?
    A: This kit is specifically designed for the Vertiv Avocent ACS 800 Serial Console. Compatibility with other models is not guaranteed; consult the product documentation or Vertiv support for guidance on alternative mounting solutions.
  • Q: Can I install this kit on drywall or only on concrete walls?
    A: For best results and safety, install on solid backing such as wall studs or concrete surfaces using appropriate anchors. Drywall alone is not recommended unless reinforced and properly anchored.
  • Q: Does the kit include all mounting hardware?
    A: Yes, the kit includes the necessary brackets, screws, and wall anchors to support standard installation scenarios. Additional site-specific hardware may be required depending on wall construction.
  • Q: Do I need special tools to install the rack mount kit?
    A: Most installations can be completed with common hand tools (screwdrivers, drill, level). Specialized tools are not typically required, but following the included instructions ensures a secure setup.
  • Q: Will this kit affect airflow or cooling around the ACS 800 console?
    A: The wall-mount design, combined with proper cable management, is intended to support good airflow around the console. Ensure that vents are not blocked and that the installation maintains adequate clearance for cooling.

Customer reviews

(0)

0 Out of 5 Stars


5 Stars
0
4 Stars
0
3 Stars
0
2 Stars
0
1 Star
0


Showing - Of Reviews


You may also like

Recently viewed