Vertiv Startup Installation Services for Vertiv Liebert GXT4 UPS Models up to 3kVA Includes Removal of Existing UPS o 3kva 7x24 Wr

LiebertSKU: 5467968

Price:
Sale price$1,767.41

Description

Ensure mission-critical reliability from day one with Vertiv Startup and Installation Services for Liebert GXT4 UPS models up to 3 kVA. This comprehensive service is designed to minimize equipment-related downtime by delivering a precise, professionally executed installation that sets up your power management system correctly. From mounting to startup and rigorous testing, this service verifies proper operation with connected equipment, delivering improved system reliability and seamless integration across your IT and facilities environments. The program is tailored for Liebert GXT4 UPS units up to 3 kVA and includes an operational tour that trains your team on how to operate and monitor the system. A 7x24WR support option ensures around-the-clock readiness for any post-installation questions or small adjustments, helping you maintain uptime and peace of mind in a demanding business landscape.

  • Minimize downtime and installation risks: The Vertiv startup process is performed by trained technicians who follow validated procedures to ensure the UPS and related components are installed correctly from the start, reducing the likelihood of post-install issues that can disrupt business operations.
  • Enhanced reliability through validated testing and integration: The service includes comprehensive testing to verify proper operation with connected equipment, ensuring that the Liebert GXT4 UPS is fully integrated with your load, monitoring systems, and environment before going into production.
  • On-site training and operational familiarity: At startup, your team receives an operational tour and hands-on guidance to understand how to monitor alarms, interpret indicators, and perform routine maintenance, so operators can confidently manage the power protection system.
  • Flexible scope with optional removal of legacy equipment: If you are upgrading from an existing UPS or External Battery Cabinet (EBC), the service can include removal and disposal of old equipment (where permitted), streamlining the transition and consolidating responsibility with Vertiv.
  • Designed for Liebert GXT4 units up to 3 kVA with continuous support: The service is tailored to the Liebert GXT4 family, including 7x24WR coverage to address urgent needs, questions, and follow-up support, keeping critical systems protected around the clock.

Technical Details of Vertiv Startup Installation Services for Liebert GXT4 UPS Models up to 3 kVA Includes Removal of Existing UPS

  • Service scope: On-site mounting and startup of a new Vertiv Liebert GXT4 UPS or External Battery Cabinet (EBC), excluding hard-wired applications.
  • Optional removal: Removal and disposal of the existing UPS or EBC equipment can be included if selected during scheduling.
  • Support window: 7x24WR coverage to provide rapid assistance, troubleshooting, and confirmation of proper operation after installation.
  • Outcome: Verified and tested integration with connected equipment, resulting in improved system reliability and predictable performance under load.
  • Training: An operational tour and client instruction on equipment operation are included at startup to empower ongoing independent management.

How to Install Vertiv Startup Installation Services for Liebert GXT4 UPS Models up to 3 kVA

  • Step 1 — Schedule and define scope: Work with Vertiv or your authorized partner to schedule the startup service, confirm the scope (including optional removal of existing UPS/EBC), and align on site access, power paths, and load requirements.
  • Step 2 — Prepare the installation site: Confirm adequate space for mounting, ensure mounting surfaces meet load and environmental specifications, check clearance for safe maintenance access, and verify that electrical connections and outlet provisions meet applicable codes and standards.
  • Step 3 — Install mounting hardware and position the UPS/EBC: Technicians mount the Liebert GXT4 UPS (and any accompanying EBC, if applicable) in a designated enclosure or rack, secure cabling paths, and verify mechanical stability before electrical connections.
  • Step 4 — Connect and configure: Configure firmware, network or monitoring integration (SNMP or other supported interfaces), and set alarm thresholds. Connect the UPS to the connected equipment, main input power, and bypass pathways as required by your configuration.
  • Step 5 — Perform startup and functional testing: Power up the system, run a sequence of functional tests, verify battery health where applicable, perform load testing within rated capacity, and confirm proper operation with connected equipment through simulated faults or real load.
  • Step 6 — Optional removal of existing UPS/EBC: If you selected removal, safe decommissioning and disposal of the old equipment will be conducted in accordance with environmental and regulatory guidelines, ensuring no residual hazards or interference with current operations.
  • Step 7 — Operational tour and knowledge transfer: The technician conducts an on-site walkthrough, explains normal operating procedures, alarms, and maintenance tasks, and provides documentation to your team for ongoing reference.
  • Step 8 — Documentation and handover: Receive installation records, test results, warranty information, and contact details for ongoing Vertiv support, ensuring you have a clear point of contact for any future questions or service needs.

Frequently Asked Questions

  • What exactly is included in Vertiv Startup Installation Services for Liebert GXT4 UPS up to 3 kVA? The service includes on-site mounting and startup of the UPS or External Battery Cabinet (EBC), testing for proper operation with connected equipment, and an operational tour for user training. Optional removal and disposal of an existing UPS/EBC is available if selected during scheduling. Hard-wired applications are excluded from this service.
  • Is removal of an existing UPS or EBC always included? No. Removal and disposal are optional add-ons. They can be selected during scheduling, allowing a seamless transition from old to new equipment as part of the service package.
  • What kind of testing is performed? A comprehensive set of functional tests verifies that the Liebert GXT4 UPS is properly integrated with the load and monitoring systems. Tests confirm battery health (where applicable), alarm signaling, communication with monitoring software, and overall readiness for live operation.
  • Does this service cover hard-wired installations? No. The startup service excludes hard-wired applications. If your environment requires hard-wired integration, you’ll need to coordinate with Vertiv for a different scope or a separate install service.
  • What is the benefit of the 7x24WR option? 7x24WR provides around-the-clock coverage and rapid support for startup-related questions, post-install adjustments, or emergencies, helping to maintain uptime and quickly resolve any issues that arise after installation.
  • How long does the installation usually take? Turnaround times vary by site and configuration, but the process is designed to minimize downtime by planning the sequence, coordinating with facilities, and executing a controlled startup with verification steps integrated into a single service visit.

Customer reviews

(0)

0 Out of 5 Stars


5 Stars
0
4 Stars
0
3 Stars
0
2 Stars
0
1 Star
0


Showing - Of Reviews


You may also like

Recently viewed