Description
Vertiv VR Rack Accessory VRA Copper BUS Bar for 42U Racks (VRA6042)
The Vertiv™ VR Rack Accessory VRA Copper BUS Bar for 42U racks is a purpose-built solution designed to boost grounding reliability, optimize heat dissipation, and improve overall electrical performance within high-density data centers. Specifically engineered for the 42U Vertiv VR Rack system, this copper bus bar delivers a low-impedance grounding path that supports efficient current distribution and enhances system stability under varying load conditions. By integrating this robust copper bus bar into your VR Rack infrastructure, you gain a dependable foundation for safer operation, reduced electrical noise, and improved uptime—crucial factors in modern, sustainability-focused data centers.
- Enhanced grounding and current distribution: The copper bus bar provides a low-impedance, high-conductivity path that minimizes ground loop potential and ensures consistent electrical performance across the entire 42U Vertiv VR Rack. This results in more reliable equipment operation and reduced risk of grounding-related faults during peak power events.
- Efficient heat dissipation and current handling: Copper’s excellent thermal conductivity helps transfer heat away from critical components, supporting more uniform temperature profiles within the rack and aiding thermal management strategies. This can contribute to fewer hotspots and improved equipment longevity in dense configurations.
- Durable, corrosion-resistant construction: The VRA6042 copper bus bar is built to withstand rigorous data-center environments, with a finish designed to resist corrosion and mechanical wear. This durability translates to long service life and lower maintenance overhead for mission-critical racks.
- Easy integration with Vertiv VR Rack systems: Designed for seamless compatibility with 42U Vertiv VR Rack configurations, the bus bar aligns with standard mounting patterns and comes with the necessary hardware for straightforward installation, reducing downtime and complexity during rack upgrades or expansions.
- Supports sustainability and efficiency goals: By delivering a stable grounding path and efficient heat management, the copper bus bar helps optimize electrical performance, potentially lowering energy waste and contributing to greener data-center operations without compromising reliability.
Technical Details of Vertiv VR Rack Accessory VRA Copper BUS Bar | 42U
- Model: VRA6042
- Product Type: Copper BUS Bar for 42U Vertiv VR Rack
- Material: Copper (high-conductivity copper suitable for grounding and current distribution)
- Finish: Corrosion-resistant coating for durability in data-center environments
- Compatibility: Vertiv VR Rack systems configured for 42U installations
- Mounting: Standard 19" rack mounting footprint with mounting hardware included
- Dimensions (approximate): Sized for 42U Vertiv VR Rack width and mounting pattern
- Weight (approximate): Lightweight copper construction designed for easy handling during installation
- Application: Grounding, current distribution, and heat-dissipation support within rack infrastructure
how to install Vertiv VR Rack Accessory VRA Copper BUS Bar
Before beginning installation, power down equipment and follow your facility’s safety procedures. Verify that the rack space is clear and that the 42U Vertiv VR Rack is accessible for mounting the VRA6042 copper bus bar. Use the included hardware and ensure all connections are clean and free of debris to maximize electrical contact and longevity.
Step 1: Prepare the rack and bus bar. Inspect the copper bus bar for any shipping damage and confirm that mounting holes align with the VR Rack’s rail interface. Clean any dust or oxidation from contact points if needed to ensure a solid electrical connection.
Step 2: Align with mounting pattern. Position the copper bus bar so that its mounting holes line up with the standard 19" rack rails of the 42U Vertiv VR Rack. Carefully orient the bar to optimize grounding path continuity across the rack frame and power distribution components.
Step 3: Secure the bus bar. Use the supplied mounting hardware to fasten the copper bus bar to the rack rails. Tighten hardware to the manufacturer’s recommended torque to avoid loosening during equipment movement or thermal cycling.
Step 4: Connect grounding/grounding-strap points. Attach any designated grounding straps or connectors to the bus bar as specified by your data-center grounding plan. Ensure secure, clean contact between the bus bar and the grounding points on the rack chassis and power distribution units if applicable.
Step 5: Verify continuity and integrity. Perform a continuity check across the grounding path and inspect all fasteners for tightness. Confirm that the bus bar is firmly mounted, with no loose components, to maintain reliable performance under load.
Step 6: Power up and test. Restore power to the equipment and monitor grounding stability, thermal behavior, and any electrical noise indicators. If you notice irregularities, re-check connections and torque, then re-test until the system shows a clean, stable electrical profile.
Frequently asked questions
What is the primary purpose of the Vertiv VR Rack Copper BUS Bar? The copper bus bar provides a low-impedance grounding path and supports efficient current distribution within 42U Vertiv VR Rack configurations, contributing to safer operation and more predictable electrical performance in high-density data-center environments.
Is this bus bar compatible with all 42U racks? The VRA6042 is specifically designed for Vertiv VR Rack systems configured as 42U installations. It is intended to integrate with Vertiv’s VR Rack ecosystem and mounting patterns to ensure proper fit and performance.
What tools are required for installation? Standard hand tools for rack mounting, typically including a screwdriver and a torque driver if specified by the hardware, are sufficient. The package includes the required mounting hardware for straightforward installation.
Does the copper bus bar contribute to energy efficiency? While its primary functions are grounding reliability and heat dissipation, these improvements can help reduce electrical impedance and promote more stable operation, which supports overall data-center efficiency and uptime goals as part of a well-designed electrical infrastructure.
What materials are used and is it protected against corrosion? The bus bar is made from high-conductivity copper and finished with a corrosion-resistant coating intended to endure the demanding conditions of data-center environments, helping to preserve contact quality over time.