VERTIV VR Rack Vertical Exhaust Duct

VERTIVSKU: 7649455

Price:
Sale price$1,371.24

Description

VERTIV VR Rack Vertical Exhaust Duct

Designed to optimize airflow management in data centers, network closets, and enterprise IT environments, the Vertiv VR Rack Vertical Exhaust Duct provides a streamlined solution for returning hot air from rack-mounted equipment back into the room cooling system. This component is engineered to work seamlessly with the Vertiv VR Rack family, delivering a reliable, scalable path for thermal air that helps maintain consistent temperatures, reduce hot spots, and improve overall cooling efficiency. By channeling heat away from critical components and feeding it back into the building’s cooling loop, this vertical exhaust duct supports lower energy consumption and longer equipment life, making it a smart choice for organizations that prioritize performance and reliability in high-density deployments. When paired with the Networking Roof Panel, the VR Rack Vertical Exhaust Duct supports zero U installation, preserving valuable rack space for more equipment while maintaining optimal airflow flow paths. In environments where space, efficiency, and uptime are paramount, this duct is a pivotal piece of an effective cooling strategy that aligns with modern IT infrastructure goals.

  • Efficient hot-air return: The Vertiv VR Rack Vertical Exhaust Duct creates a direct, low-resistance pathway for hot air to travel from the rear of the cabinet back to the room cooling system, helping to maintain stable temperatures and reduce hotspots within dense rack configurations.
  • Zero-U installation when paired with Networking Roof Panel: This duct enables a zero-U configuration, reclaiming valuable vertical rack space and keeping top-of-rack and cabling areas clear for enhanced airflow and easier serviceability.
  • Durable, data-center-ready construction: Built for demanding environments, the exhaust duct uses high-quality materials with a resistant finish to withstand routine maintenance, dust, and airflow rigors typical of data centers and network closets.
  • Seamless integration with Vertiv VR Rack systems: Specifically designed to align with the Vertiv VR Rack family, it simplifies installation, ensures secure mounting, and delivers predictable airflow behavior when used as part of a broader cooling strategy.
  • Energy-conscious cooling improvement: By improving the efficiency of hot-air removal, the duct helps support steadier operating temperatures, potentially reducing the load on CRAC/air handler systems and contributing to overall energy savings in high-density deployments.

Technical Details of VERTIV VR Rack Vertical Exhaust Duct

  • Voltage: 120 VAC
  • Material: Steel with a durable powder-coated finish
  • Finish/Color: Charcoal gray powder coat designed for data-center aesthetics and corrosion resistance
  • Mounting/Compatibility: Zero-U compatible when used with the Networking Roof Panel; designed for Vertiv VR Rack family configurations
  • Application: Vertical exhaust duct intended to return hot air from cabinet interiors to the room cooling system, enhancing overall airflow management

How to install VERTIV VR Rack Vertical Exhaust Duct

  • Plan your cooling strategy by identifying the appropriate Vertiv VR Rack model and confirming compatibility with the Networking Roof Panel for zero-U installation.
  • Power down the rack area and follow standard safety protocols before beginning any work in the data center or IT room.
  • Position the Vertical Exhaust Duct at the rear of the cabinet, aligning it with rear exhaust ports and ensuring clearance for cables and components.
  • Attach the duct securely to the rack framework, then integrate it with the Networking Roof Panel to achieve the zero-U configuration. Use manufacturer-recommended fasteners and verify a snug, airtight fit.
  • Inspect all connections for proper sealing and ensure there are no kinks or obstructions in the airflow path. Route cable management and intake/exhaust clearances to maintain optimal air movement.
  • Reconnect power and perform a controlled airflow test. Monitor the return path to ensure hot air is effectively fed back into the room cooling system and that there are no leaks or channeling issues that could compromise performance.

Frequently asked questions

  • Q: What is the primary purpose of the Vertiv VR Rack Vertical Exhaust Duct? A: It provides an efficient, dedicated path to return hot air from a rack to the room cooling system, improving thermal management and overall cooling efficiency for high-density deployments.
  • Q: Can the exhaust duct be used without the Networking Roof Panel? A: It is designed to be most effective when paired with the Networking Roof Panel for zero-U installation, but it can be used in compatible setups where a secure, sealed connection to the cooling path is achievable.
  • Q: Is the exhaust duct compatible with all Vertiv VR Racks? A: The duct is designed to integrate with the Vertiv VR Rack family and related networking components; verify compatibility with your exact model and configuration in the product documentation.
  • Q: What electrical specifications does the system require? A: The assembly operates with a standard 120 VAC power supply common in data centers and IT rooms, aligning with typical rack-mount infrastructure requirements.
  • Q: What maintenance is required? A: The duct is built for durability, but routine inspections of the exhaust path are recommended to confirm unobstructed airflow and to remove any accumulated dust or debris that could impede performance.