Wiremold 4000 Take-Off Connector (4000 to 3000 Series Raceway) Fitting

WiremoldSKU: 7100859

Price:
Sale price$111.16

Description

Wiremold 4000 Take-Off Connector (4000 to 3000 Series Raceway) Fitting

The Wiremold 4000 Take-Off Connector is the smart, durable solution for routing power, data, and low-voltage services from 4000 Series surface raceways into 3000 Series channels. Built for commercial, institutional, and industrial environments, this fitting delivers a clean, professional transition with high cable capacity and flexible, multi-service capabilities. Designed to simplify multi-path installations and future reconfigurations, it helps keep spaces organized, compliant, and easy to service while maintaining a sleek, integrated look.

  • Dual-service versatility: Supports multi-service applications by allowing branching from 4000 Series Raceway into one or more 3000 Series paths. This enables simultaneous power and communications routing without clutter, simplifying complex layouts and future upgrades. Ideal for offices, schools, hospitals, and manufacturing facilities that demand reliable service distribution with minimal footprint.
  • Seamless transitions and clean fits: Specifically engineered to align precisely with both 4000 and 3000 series profiles, delivering a smooth, uninterrupted path for cables. The take-off design minimizes sharp corners and bends, helping protect conductors and maintain signal integrity for data and low-voltage systems.
  • Durable construction: Built for harsh environments common in commercial and industrial settings. The connector uses rugged metal components with corrosion-resistant finishes to withstand daily wear, cleaning regimens, and the rigors of high-traffic areas while retaining a professional appearance.
  • Easy installation and maintenance: Engineered for straightforward mounting with standard raceway hardware. The design enables quick alignment, secure attachment, and accessible cable management, reducing installation time and facilitating routine maintenance or future reconfiguration without heavy disassembly.
  • Reliability and safety: Engineered to meet industry standards for surface raceway systems, delivering steady performance under load and with respect to heat dissipation and cable containment. When paired with the 4000 and 3000 series raceways, it provides a robust, code-compliant solution for busy facilities that require durable, long-lasting service distribution.

Technical Details of Wiremold 4000 Take-Off Connector (4000 to 3000 Series Raceway Fitting)

  • Compatibility: 4000 Series Raceway to 3000 Series Raceway transition fitting, enabling efficient cross-path routing between system generations.
  • Configuration: Take-off connector designed to branch one 4000 path into multiple 3000 paths or to re-route services as needed for multi-service installations.
  • Material & Finish: Rugged metal construction with a protective finish suitable for commercial and industrial environments; finish may vary by batch but adheres to standard Wiremold specifications.
  • Mounting Method: Attaches to existing raceways using standard mounting hardware and techniques; designed for fast alignment and secure attachment with minimal tools.
  • Applications: Ideal for commercial, institutional, and industrial applications needing high cable capacity and dual-service routing without compromising fit and finish.

How to Install Wiremold 4000 Take-Off Connector

  • Plan your route: Evaluate the workspace to determine where the 4000 to 3000 transition is most efficient, considering cable density, accessibility, and future expansion needs. Ensure power and data pathways remain compliant with local codes throughout the installation.
  • Prepare the raceways: Clean mating surfaces on both the 4000 and 3000 series raceways. Remove any obstructions and verify alignment points so the take-off connector seats flush and distributes load evenly across the mating faces.
  • Position the connector: Align the take-off connector with the intended 4000 and 3000 series raceways. Temporarily secure with clamps if needed to hold alignment while you install mounting screws.
  • Secure the assembly: Drive mounting screws through the connector’s mounting holes into the raceways, ensuring a tight, square fit without overtightening. Check for a snug fit and confirm that all edges are flush to prevent cable snagging or future misalignment.
  • Manage cables and cover: Route cables through the take-off connector’s internal cavities with minimal bends, then snap or screw on any covers or faceplates as required. Verify clearances around the connector and test the pathway by gently pulling cables to confirm secure seating before powering up.

Frequently asked questions

  • Q: What is the primary purpose of the Wiremold 4000 Take-Off Connector?
    A: It serves as a transition fitting that joins a 4000 Series surface raceway to 3000 Series raceways, enabling clean, multi-service routing and expansion without exposing cables or creating clutter.
  • Q: Is this connector suitable for commercial and industrial installations?
    A: Yes. It is designed for heavy-duty, high-traffic environments and supports the multi-service needs typical in commercial, institutional, and industrial settings.
  • Q: Can I use this take-off connector to route both power and data cables?
    A: The connector is intended for multi-service applications, including power, data, and low-voltage solutions, while maintaining proper separation and cable management within the raceways.
  • Q: What installation considerations should I keep in mind?
    A: Plan the route for accessibility and future upgrades, ensure proper alignment with both raceways, secure the connector with appropriate mounting hardware, and verify clearances before applying power to the system.

Customer reviews

(0)

0 Out of 5 Stars


5 Stars
0
4 Stars
0
3 Stars
0
2 Stars
0
1 Star
0


Showing - Of Reviews


You may also like

Recently viewed