Description
Wiremold Rack Mount 120V/20A/6 Rear O/L /Lighted Switch/15' Cord
Designed for demanding data centers, enterprise server rooms, and high-density networking closets, the Wiremold Rack Mount 120V/20A/6 Rear O/L /Lighted Switch/15' Cord is a compact, high-performance power distribution unit (PDU) that brings organized, reliable power to multiple devices. This 1U, rack-mountable PDU delivers a clean, balanced electrical feed to servers, switches, storage, and other critical equipment, helping you optimize uptime, simplify cabling, and maintain full control over energy usage. With six NEMA 5-20R outlets, a rear-oriented layout, a lighted on/off switch, and a long 15-foot cord, it’s the smart choice for modern rack deployments where space, visibility, and safety matter.
- Six NEMA 5-20R outlets in a slim 1U chassis – Provides ample, rear-macing power sockets for servers and rack-mounted devices while keeping your rack footprint compact and organized.
- Rear O/L protection for safe, balanced operation – Overload-aware design helps prevent overcurrent conditions and balances load across outlets, reducing the risk of equipment damage in dense environments.
- Lighted switch for quick power status at a glance – The illuminated on/off switch lets you confirm power presence instantly during maintenance, installations, or quick reboots without guesswork.
- Generous 15 ft cord for flexible deployment – A long, sturdy cord provides versatility in rack layouts, allowing you to position the PDU where you need it most while minimizing clutter and strain on cables.
- Rack-mountable, 1U form factor with TAA compliance – Built to fit standard server racks and meet procurement requirements for federal and enterprise buyers, ensuring compatibility with data-center standards and purchasing policies.
Technical Details of Wiremold Rack Mount 120V/20A/6 Rear O/L /Lighted Switch/15' Cord
- Voltage: 120 VAC
- Current rating: 20 A
- Outlet configuration: 6 x NEMA 5-20R
- Cord length: 15 ft
- Form factor: 1U rack-mountable
- Protection: Rear overload protection (O/L)
- Switch: Lighted on/off switch for status indication
- Compliance: TAA compliant
- Application: Distributes AC power to multiple servers, networking gear, and other IT equipment; balances load across outlets for reliability
How to Install Wiremold Rack Mount 120V/20A/6 Rear O/L /Lighted Switch/15' Cord
Installing this PDU is straightforward for IT professionals or experienced technicians. Follow these steps to ensure a secure, compliant setup that maximizes performance and safety:
- Prepare the rack – Confirm that the rack or cabinet supports 1U devices and that the mounting rails have the appropriate spacing. Clear away other cables to create an unobstructed installation space.
- Mount the PDU – Use the standard rack screws to secure the 1U PDU into the selected rack position. Ensure the unit is level and firmly fastened to prevent shifting during maintenance or vibration from doors and fans.
- Route the cord – Position the 15 ft power cord so it reaches a suitable 120 VAC power source without creating tension or kinks. Maintain clean cable management to promote airflow and reduce interference with cooling fans.
- Connect to power – Plug the 120V supply into a compatible outlet or UPS-protected circuit. Verify that the main power source is stable and meets the 20 A rating required by the PDU and connected devices.
- Power on and verify – Switch the PDU to the ON position. Confirm the lighted switch indicates power and that connected devices receive power. Check each outlet with a safe load to ensure balanced distribution.
- Organize and label – Use cable ties or Velcro straps to tidy cords and label outlets if needed. Proper labeling helps with future maintenance and load balancing across the rack.
- Test and monitor – If you have monitoring systems, integrate the PDU into your environmental or power-management platform to track current, voltage, and outlet status for ongoing reliability.
Frequently asked questions
- What outlets does this PDU provide? It features 6 x NEMA 5-20R outlets designed for 120 V, 20 A loads, suitable for servers and networking devices in standard racks.
- What is the cord length? The PDU includes a 15-foot cord, offering flexibility to reach distant power sources in larger or multi-rack environments.
- Is the PDU rack-mountable? Yes. It is designed as a 1U, rack-mountable device to fit standard server racks and data-center enclosures.
- Does it include overload protection? The unit features rear overload protection (O/L) to help prevent overloading individual outlets and support safer operation in dense deployments.
- Is this PDU compliant for government procurement? Yes, the model is TAA compliant, making it suitable for federal and other government purchasing programs.
- What is the benefit of the lighted switch? The illuminated switch provides immediate visual confirmation of power status, facilitating quick maintenance and reducing guesswork during installations or reboots.
- What kind of load balancing does it offer? The PDU is designed to distribute power efficiently across its six outlets, helping balance loads among connected servers, storage devices, and networking gear to improve uptime and performance.