Description
Wiremold RC9AFFTC Assembled Furniture Feed Poke-Thru Device
The Wiremold RC9AFFTC Assembled Furniture Feed Poke-Thru Device delivers the next level of versatility for built-in power, data, and AV connectivity. Traditionally, poke-thru devices were limited to select locations, but Evolution poke-thru solutions from Wiremold break those boundaries, enabling installations throughout a building from desks and conference tables to workstations and communal surfaces. This assembled unit is designed to be user-friendly, high-capacity, and visually unobtrusive, so you can bring essential connections exactly where you need them without sacrificing aesthetics or performance. Whether you’re outfitting a modern office, a hospitality space, or a collaborative learning environment, this poke-thru device helps you keep cables organized, accessible, and compliant with industry standards.
- The RC9AFFTC is designed to provide flexible access to power, data, and multimedia interfaces wherever you need them—on furniture, within conference tables, or across modular workstations—without forcing compromises on workflow or layout. It integrates seamlessly with a wide range of faceplates and module configurations, empowering you to tailor connections to your unique requirements while maintaining a clean, professional look. This versatility is especially valuable in spaces that frequently reconfigure for meetings, training sessions, or collaborative projects, ensuring that technology keeps pace with your evolving needs.
- Engineered for efficient installation and long-term reliability, this assembled poke-thru device minimizes field labor while delivering robust performance. Its compact footprint and ergonomic design reduce installation complexity, so you can complete upgrades or relocations quickly. The unit is built to withstand daily use in office environments, with attention paid to securing internal components, reducing wear on connectors, and simplifying future maintenance or upgrades. The result is a dependable, low-maintenance solution that supports a wide range of facility layouts.
- Faceplates and modular trays offer a clean, professional appearance with easy access to internal modules. The system is designed for straightforward module swapping and cable management, enabling you to add, remove, or reconfigure ports as your connectivity needs evolve. This modular approach helps prevent unnecessary wall or furniture remodeling while enabling a tidy, organized workspace where cables are routed out of sight and out of the way of users and chairs.
- Durable construction and thoughtful finishes ensure you get a poke-thru device that stands up to daily wear in high-traffic areas. The RC9AFFTC typically features a sturdy enclosure, corrosion-resistant surfaces, and hardware designed to resist tampering and accidental damage. Sealing and gasket options help protect sensitive connections from dust and moisture, contributing to the longevity of your investment and reducing service calls in busy environments.
- Designed with safety and compliance in mind, this poke-thru device supports industry-standard practices for electrical and data installations. Its architecture accommodates multiple power and data configurations while aligning with common building codes and industry guidelines. The result is a solution that helps facilities managers maintain orderly, code-compliant spaces without sacrificing convenience or performance for end users.
Technical Details of Wiremold RC9AFFTC
- Model: RC9AFFTC
- Product Type: Assembled Furniture Feed Poke-Thru Device
- Mounting: Surface mount and furniture cut-out compatible
- Construction: Steel enclosure with protective finishes and gasketed interfaces
- Finish: Finish options vary by project specifications; consult product documentation for exact availability
- Electrical/Data Ports: Modular layout supports power, data, and multimedia ports as configured
- Warranty: Manufacturer's limited warranty (see product documentation for details)
- Compliance: Designed to help meet applicable industry codes; verify local requirements for your installation
- Dimensions: Customizable per configuration; refer to engineering drawings in the official spec sheet
- Included Hardware: Hardware kit for secure installation and module mounting
How to install Wiremold RC9AFFTC
- Plan the poke-thru location carefully by evaluating desk and table dimensions, access to power and data pathways, and proximity to wall outlets or data hubs. Confirm that the chosen opening can accommodate the module layout and that there is adequate clearance for cable management and future maintenance.
- Shut off relevant power circuits and verify that the installation area is safe for electrical work. Gather the required tools, including a cut-out template, measuring devices, and the appropriate mounting hardware supplied with the RC9AFFTC kit. Double-check that your work surface can support the added weight and stress of the poke-thru device.
- Prepare the furniture or surface by marking the cut-out location and using a template to guide the opening. Use precise measurements to ensure a clean, square cut that aligns with the device chassis and faceplates. Clear away debris and ensure the surrounding area remains accessible for routing cables and reaching connectors behind the panel.
- Cut the opening per the template specifications, taking care to create smooth edges and avoid splintering. Deburr the sides of the cut-out to prevent snagging of cables during installation. Prepare for the insertion of the poke-thru housing by cleaning any dust or debris that could interfere with a tight seal.
- Insert the assembled RC9AFFTC unit into the cut-out, aligning mounting points with the furniture or surface and securing it with the included hardware. Ensure the enclosure sits flush with the surface to maintain a professional appearance and to avoid creating a tripping hazard or snag points for users.
- Connect the power, data, and any auxiliary ports according to the configuration you’ve chosen. Route cables through internal trays or channels to minimize strain and prevent interference with other components. Use cable ties or guides to maintain neat organization and allow for easy upgrades or reconfiguration in the future.
- Attach the corresponding faceplates and modular modules, making sure each port remains accessible and clearly labeled. Verify that all ports seat properly and that the faceplates are aligned for a uniform look. If your installation includes multimedia interfaces or data modules, ensure all connectors are fully seated and tested before sealing the enclosure.
- Test the poke-thru device by powering the connected modules and verifying signal integrity across data lines, power delivery, and multimedia interfaces. Check for any overheating, unusual noise, or intermittent connections. If issues arise, re-check cable routing, port seating, and module configuration before re-testing.
- Seal and finish the installation by rechecking the exterior for gaps, ensuring gaskets are seated, and confirming the surface remains smooth and flush. Provide any required touch-up finishes to match surrounding furniture and confirm maintenance access is preserved for future service or upgrades.
- Document the installation with photos and notes for maintenance records and future reference. Include port configurations, module types, and any deviations from standard layouts to assist technicians during service calls or upgrades.
Frequently asked questions
-
Q: What is a poke-thru device?
A poke-thru device is a modular system that allows power, data, and multimedia connections to be brought through or into furniture surfaces such as desks and tables. It helps maintain clean cable management, reduces clutter, and makes it easy to reconfigure spaces without invasive remodeling.
-
Q: What makes the RC9AFFTC different from other poke-thru solutions?
A key differentiator is its assembled, versatile design that supports multiple configurations, enabling installation across a variety of furniture and surface types. The RC9AFFTC emphasizes ease of installation, modular port options, and durable construction suitable for busy environments where reliability and aesthetics matter.
-
Q: Is the RC9AFFTC UL-listed or compliant with industry codes?
Yes, the RC9AFFTC is engineered to support compliance with applicable electrical and data installation standards. Always verify local regulatory requirements and consult the official product documentation to ensure compatibility with your project’s codes and standards.
-
Q: Can I customize the ports or modules used with the RC9AFFTC?
Yes. The poke-thru ecosystem is designed to be modular, allowing you to select and configure power, Ethernet, USB, audio/HDMI, and other interfaces to meet current needs and adapt to future changes without replacing the entire unit.
-
Q: How do I maintain or upgrade an installed RC9AFFTC?
Maintenance typically involves inspecting ports for wear, re-seating connectors, and ensuring gaskets and seals remain intact. Upgrades can often be accomplished by swapping modules or adding additional faceplates to expand the available ports, minimizing downtime and preserving the workspace’s appearance.
Customer reviews
Showing - Of Reviews
