Description
Wiremold S4014A Mounting Box - Stainless Steel
Built for reliability and longevity, the Wiremold S4014A Mounting Box in stainless steel delivers a sleek, corrosion-resistant solution for surface-mounted electrical installations. Designed to accommodate a versatile range of wiring configurations, this mounting box combines rugged durability with flexible knockout options, making it ideal for commercial, industrial, and design-conscious interiors where both safety and aesthetics matter. The included cover and ground terminals ensure a complete, ready-to-install package that adheres to RoHS material restrictions, helping you meet modern environmental and safety standards without compromising performance.
- The base provides an extensive array of knockouts to support complex wiring layouts: two concentric 3/4" and 1/2" trade size knockouts, two concentric 1 1/4" and 1" trade size knockouts (undivided only), plus two rectangular openings measuring 2 9/16" by 1 11/16" (65 mm x 43 mm). This combination offers maximum flexibility for conduit, raceway, and cable entries while maintaining a clean, professional appearance in finished installations.
- Includes a sturdy cover and two No. 10-32 ground terminals, enabling quick, compliant grounding right out of the box. The cover provides a secure enclosure for conductors and fittings, helping protect against dust, debris, and accidental contact while maintaining easy access for service or re-entry when needed.
- Constructed from durable stainless steel, delivering superior corrosion resistance and a professional, modern look that complements stainless finishes in contemporary spaces. This makes the S4014A well-suited for environments with higher humidity or through-wall exposure where longevity is a priority.
- RoHS-compliant materials ensure the mounting box meets current environmental and health standards for restricted hazardous substances, helping your installation align with European Union directives and global sustainability requirements without sacrificing performance or compatibility with standard electrical components.
- Designed for seamless integration with Wiremold raceways and systems, the S4014A supports clean, organized wiring layouts that enhance safety, ease of maintenance, and overall aesthetic appeal in both new construction and retrofit projects. The stainless steel construction combines with Wiremold’s proven mounting solutions to deliver a cohesive, professional electrical infrastructure.
Technical Details of Wiremold S4014A Mounting Box
- Material: Stainless steel mounting box with RoHS-compliant construction
- Knockouts: Base includes two concentric 3/4" and 1/2" trade size KOs, two concentric 1 1/4" and 1" trade size KOs (undivided only), plus two rectangular 2 9/16" x 1 11/16" (65 mm x 43 mm) openings
- Includes: Cover and two No. 10-32 ground terminals
- Finish: Stainless steel surface suitable for modern interiors and high-durability environments
- Compliance: RoHS-compliant material restrictions for safer, environmentally-conscious installations
How to install Wiremold S4014A Mounting Box
- Plan your layout by identifying the required knockout sizes for your conduit, cable, or raceway connections. Confirm that the two concentric 3/4" and 1/2" KOs, the two concentric 1 1/4" and 1" KOs (undivided only), and the two rectangular openings are positioned to optimize cable routing and access.
- Prepare the mounting surface. Ensure the wall or mounting surface is clean, level, and capable of supporting the mounting box and attached hardware. If necessary, locate studs or use appropriate wall anchors for added support, especially in high-traffic or load-bearing installations.
- Drill or form the knockout openings as required and inspect for clearance. Double-check that there is sufficient space behind the mounting area to accommodate the connector fittings and the conductors without crowding or bending wires at sharp angles.
- Mount the box to the surface using appropriate screws or fasteners that suit the substrate. Ensure the box sits flush against the wall with no gaps that could trap dust or allow moisture ingress. Tighten fasteners to a secure, vibration-free fit without over-tightening, which could distort the box or mounting surface.
- Terminate conductors and install fittings. Run cables or conduit through the selected knockouts, secure with appropriate connectors, and connect grounds using the two No. 10-32 ground terminals included. Verify that all connections are tight and that there is no undue strain on wires.
- Attach the cover for a finished, enclosed appearance. Ensure the cover aligns properly with the box and snaps or screws into place, providing protection from dust, debris, and incidental contact while preserving easy access for future maintenance or upgrades.
- Perform a final safety check. Confirm that all conductors are properly terminated, ground connections are secure, and the assembly complies with applicable electrical codes. If necessary, have a qualified electrician review the installation to ensure proper grounding and enclosure integrity.
Frequently asked questions
- Is the Wiremold S4014A Mounting Box RoHS compliant? Yes. The box is constructed with RoHS-compliant materials to meet environmental and health standards while maintaining optimal electrical performance.
- What knockout configurations does the S4014A offer? The base features two concentric 3/4" and 1/2" trade size knockouts, two concentric 1 1/4" and 1" trade size knockouts (undivided only), and two rectangular 2 9/16" x 1 11/16" openings (65 mm x 43 mm) to accommodate a variety of wiring methods.
- Does the package include a cover and ground terminals? Yes. The kit includes a cover and two No. 10-32 ground terminals for immediate grounding when you install the box.
- What surfaces is the S4014A suitable for? It is designed for surface-mounted electrical installations in environments where stainless steel finish and durability are advantageous. Always verify compatibility with your specific Wiremold raceway system and local electrical codes.
- Can this mounting box be used outdoors? The product description emphasizes stainless steel construction and RoHS compliance, but it does not specify outdoor-rated IP or weatherproofing. For outdoor or wet-location applications, consult the manufacturer’s guidelines or use appropriate enclosures rated for outdoor use.